Part 21 Reports - 1999

Log No Notifier Description Report Date Access No
1999-51-1 Eaton Cutler-Hammer over torquing in DS and DSL circuit breakers 11/12/1999 ml993210268
1999-51-0 Eaton Cutler-Hammer over torquing in DS and DSL circuit breakers 11/12/1999 Event Notification 36429
1999-50-1 Eaton Cutler-Hammer zinc chromate plating of hardened parts in DS and DSL circuit breakers 11/12/1999 ml993240465
1999-50-0 Eaton Cutler-Hammer zinc chromate plating of hardened parts in DS and DSL circuit breakers 11/12/1999 Event Notification 36428
1999-49-0 Nuclear Logistics direct current power supply Hope Creek 09/20/1999 9910270120
1999-48-0 Teledyne containment oxygen monitor Brunswick 10/21/1999 9910280183
1999-47-1 Scientech low-level amplifier H. B. Robinson 11/22/1999 ml993300291
1999-47-0 Scientech low-level amplifier H. B. Robinson 10/29/1999 Event Notification 36374
1999-46-3 Technology for Energy sealant environmental qualification 03/06/2000 ml003692547
1999-46-2 Technology for Energy sealant environmental qualification 12/13/1999 ml993540323
1999-46-1 Technology for Energy sealant environmental qualification 10/26/1999 ml993080072
1999-46-0 Technology for Energy sealant environmental qualification 10/26/1999 Event Notification 36350
1999-45-2 Enertech electrohydraulic actuator pressure switch indication 11/30/1999 ml993400023
1999-45-1 Enertech electrohydraulic actuator pressure switch indication 10/22/1999 9910280141
1999-45-0 Enertech electrohydraulic actuator pressure switch indication 10/22/1999 Event Notification 36332
1999-44-0 R. E. Ginna Westinghouse DB-25 circuit breaker misalignment 06/18/1999 9908090058
1999-43-2 Crystal River cable insulation damaged in fabrication 10/13/1999 9910200150
1999-43-1 Crystal River cable insulation damaged in fabrication 10/06/1999 9910120156
1999-43-0 Crystal River cable insulation damaged in fabrication 10/06/1999 Event Notification 36265
1999-42-5 Swagelok fitting seat crack 06/23/2000 Event Notification 36263 update
1999-42-4 Swagelok fitting seat crack 12/17/1999 ml993620552
1999-42-3 Swagelok fitting seat crack 11/18/1999 ml993310085
1999-42-2 Swagelok fitting seat crack 11/04/1999 ml993190386
1999-42-1 Swagelok fitting seat crack 10/06/1999  9910180050 
1999-42-0 Swagelok fitting seat crack 10/06/1999 Event Notification 36263
1999-41-0 Virgil C. Summer ABB K-Line circuit breaker trip paddle 09/23/1999 Event Notification 36218
1999-40-0 Engine Systems Woodward type EGM controller soldering 09/23/1999 9909290055
1999-39-2 Foxboro Company isolator card relay repair residual 09/13/1999 9909170178
1999-39-1 Foxboro Company isolator card relay repair residual 09/03/1999 9909080248
1999-39-0 Foxboro Company isolator card relay repair residual 09/03/1999 Event Notification 36122
1999-38-1 Inovision (Victoreen) cable connector seismic qualification 08/27/1999 9908310292
1999-38-0 Inovision (Victoreen) cable connector seismic qualification 08/27/1999 Event Notification 36082
1999-37-1 C&D Technologies battery positive plate growth Cooper Unit 1 08/25/1999 9908270106
1999-37-0 C&D Technologies battery positive plate growth Cooper Unit 1 08/25/1999 Event Notification 36073
1999-36-0 Enertech ITT pressure switch set screw 07/14/1999 9907220113
1999-35-2 Foxboro tin whiskers on relay contact support arms 07/15/1999 9907290189
1999-35-1 Foxboro tin whiskers on relay contact support arms 07/09/1999 9907150121
1999-35-0 Foxboro tin whiskers on relay contact support arms 07/09/1999 Event Notification 35906
1999-34-1 ABB-CE oscillation power range monitors 06/29/1999 9907070151
1999-34-0 ABB-CE oscillation power range monitors 06/29/1999 Event Notification 35879
1999-33-3 ABB-CE-Westinghouse 1200A 4kV vacuum circuit breaker fails to stay closed, Calvert Cliffs 07/20/2000 ml003734578
1999-33-2 ABB-CE 1200A 4kV vacuum circuit breaker fails to stay closed, Calvert Cliffs 06/30/1999 9907080312
1999-33-1 ABB-CE 1200A 4kV vacuum circuit breaker fails to stay closed, Calvert Cliffs 06/25/1999 9907010149
1999-33-0 ABB-CE 1200A 4kV vacuum circuit breaker fails to stay closed, Calvert Cliffs 06/25/1999 Event Notification 35862
1999-32-4 Boeing GTSTRUDL displacement loads 12/14/1999 ml993550180
1999-32-3 Boeing GTSTRUDL maximum joint 12/10/1999 ml993550308
1999-32-2 Boeing GTSTRUDL previous reports 08/26/1999 9909220136
1999-32-1 Boeing GTSTRUDL deletion of rigid body 07/07/1999 9907140159
1999-32-0 Boeing GTSTRUDL curved elements scurv and pcurv 06/15/1999 9906220144
1999-31-1 Rosemount model 510DU trip capacitor 06/18/1999 9906230324
1999-31-0 Rosemount model 510DU trip capacitor 06/18/1999 Event Notification 35844
1999-30-3 Nuclear Logistics direct current power supply 08/06/1999 9908180069
1999-30-2 Nuclear Logistics direct current power supply 06/30/1999 9907080108
1999-30-1 Nuclear Logistics direct current power supply 06/01/1999 9906070115
1999-30-0 Nuclear Logistics direct current power supply 06/01/1999 Event Notification 35782
1999-29-3 R. E. Ginna Westinghouse W2 control switch 11/01/1999 ml993160022
1999-29-2 R. E. Ginna Westinghouse W2 control switch 10/05/1999 9210070274
1999-29-1 R. E. Ginna Westinghouse W2 control switch 10/05/1999 Event Notification 36261
1999-29-0 R. E. Ginna Westinghouse W2 control switch 05/27/1999 9906040202
1999-28-0 Whiting Crane potential overstress 04/27/1999 9905120290
1999-27-2 R. E. Ginna Eaton control relay coil wiring 06/16/1999 9906220033
1999-27-1 R. E. Ginna Eaton control relay coil wiring 05/17/1999 9905280047
1999-27-0 R. E. Ginna Eaton control relay coil wiring 05/18/1999 Event Notification 35731
1999-26-1 San Onofre Potter and Brumfield relay contact pad weld 05/05/1999 9905110120
1999-26-0 San Onofre Potter and Brumfield relay contact pad weld 05/06/1999 Event Notification 35685
1999-25-0 R. E. Ginna power supply did not work in -25 VDC slot as expected but did work in +25 VDC slot as expected 04/23/1999 9904300200
1999-24-3 Virgil C. Summer General Electric Magne-Blast circuit breaker failed surveillance test LER 99-06 05/17/1999 9905240114
1999-24-2 Virgil C. Summer General Electric Magne-Blast circuit breaker failed surveillance test 05/05/1999 9905110154
1999-24-1 Virgil C. Summer General Electric Magne-Blast circuit breaker failed surveillance test 05/05/1999 Event Notification 35677
1999-24-0 Virgil C. Summer General Electric Magne-Blast circuit breaker failed surveillance test 04/15/1999 9904210170
1999-23-1 Cooper Energy Enterprise DSRV-16-4 diesel generator connecting rod assembly prestressed fasteners of suspected incorrect length 04/12/1999 9904160099
1999-23-0 Cooper Energy Enterprise DSRV-16-4 diesel generator connecting rod assembly prestressed fasteners of suspected incorrect length 04/12/1999 Event Notification 35580
1999-22-2 R. E. Ginna Coltec Model 730 turbocharger 05/14/1999 9805140213
1999-22-1 R. E. Ginna Coltec Model 730 turbocharger 04/09/1999 9905240075
1999-22-0 R. E. Ginna Reported a Part 21 Defect on a Replacement Turbocharger Supplied by Coltec Industries 04/09/1999 Event Notification 35567
1999-21-2 R. E. Ginna Westinghouse main steam line break model LER 99-01-1 06/21/1999 9906290303
1999-21-1 R. E. Ginna Westinghouse main steam line break model LER 99-01 03/24/1999 9903310302
1999-21-0 R. E. Ginna Westinghouse main steam line break model 02/22/1999 Event Notification 35392
1999-20-0 San Onofre Unit 2 circuit breaker shutter roller pin 03/03/1999 9903110295
1999-19-1 Clinton deficiency in commercial grade dedication process used by circuit breaker refurbishment supplier Trentec 04/30/1999 9905050003
1999-19-0 Illinois Power deficiency in commercial grade dedication process used by circuit breaker refurbishment supplier Trentec 03/12/1999 9903260199
1999-18-0 Vermont Yankee undersized actuators for scram discharge volume drain valves 02/10/1999 9902230163
1999-17-1 Foxboro Company Our notification to you, Event Number 35473, at 4:11 PM March15,1999 03/15/1999 9903170271
1999-17-0 Foxboro Company can not provide detail documentation 03/15/1999 Event Notification 35473
1999-16-1 Coltec Fairmorse Banks wrong hardening process used for valve cam rollers Indian Point Unit 2 03/08/1999 9903120178
1999-16-0 Coltec Fairmorse Banks wrong hardening process used for valve cam rollers Indian Point Unit 2 03/08/1999 Event Notification 35448
1999-15-1 Beaver Valley Unit 1 nonconservative inputs in reactor coolant system iodine concentration calculation 03/03/1999 9903110156
1999-15-0 Beaver Valley Unit 1 nonconservative inputs in reactor coolant system iodine concentration calculation 02/19/1999 Event Notification 35359
1999-14-1 ASCO hydramotor actuator failure 03/01/1999 9903090253
1999-14-0 ASCO hydramotor actuator failure 03/03/1999 Event Notification 35436
1999-13-2 PYCO resistance temperature detector winding 07/28/2000 ml003737242
1999-13-1 PYCO resistance temperature detector winding 02/25/1999 9903030171
1999-13-0 PYCO resistance temperature detector winding 02/25/1999 Event Notification 35406
1999-12-0 Thomas & Betts inappropriate low signal application of Agastat E7000 series timing relay 01/26/1999 9902020300
1999-11-2 Coltec incorrect resistor in Synchrostart speed switch in EMD diesel generator control circuitry 02/17/1999 9902190197
1999-11-1 Coltec incorrect resistor in Synchrostart speed switch in EMD diesel generator control circuitry 02/15/1999 Event Notification 35369
1999-11-0 Engine Systems incorrect resistor in Synchrostart speed switch in EMD diesel generator control circuitry 01/26/1999 9902040139
1999-10-2 Swagelok material defect in pipe fitting tee 03/03/1999 9903160153
1999-10-1 Swagelok material defect in pipe fitting tee 01/29/1999 9902030192
1999-10-0 Swagelok material defect in pipe fitting tee 01/29/1999 Event Notification 35329
1999-09-1 Integrated Resources premature failure of square root converters 02/26/1999 9903110112
1999-09-0 Integrated Resources premature failure of square root converters 01/22/1999 Event Notification 35304
1999-08-1 ABB Combustion Engineering potential nonconservative critical power ratio in SVEA-96 BWR fuel 01/15/1999 9901220118
1999-08-0 ABB Combustion Engineering potential nonconservative critical power ratio in SVEA-96 BWR fuel 01/15/1999 Event Notification 35273
1999-07-1 ABB Combustion Engineering modeling defect in BISON fast transient analysis code 01/15/1999 9901220123
1999-07-0 ABB Combustion Engineering modeling defect in BISON fast transient analysis code 01/15/1999 Event Notification 35271
1999-06-0 ABB Combustion Engineering potential manufacturing deviation in fuel assembly guide tube wear sleeves 12/01/1998 9901060170
1999-05-1 Rosemount model 1153 pressure transmitter reference document errors 01//11/1999 9901200378
1999-05-0 Rosemount model 1153 pressure transmitter reference document errors 01/12/1999 Event Notification 35243
1999-04-0 General Electric terminal block phenolic cracking 12/22/1998 9812300181
1999-03-1 Westinghouse logic error in LOCBART computer code 06/29/1999 9907120103
1999-03-0 Westinghouse logic error in LOCBART computer code 12/22/1998 9812300224
1999-02-0 Sulzer Bingham Pumps potential stress corrosion cracking in service water pump 12/14/1998 9812210318
1999-01-9 Boeing GTSTRUDL print structural data 06/15/1999 9906220141
1999-01-8 Boeing GTSTRUDL buckling analysis 04/28/1999 9905050152
1999-01-7 Boeing GTSTRUDL nonlinear analysis 04/19/1999 9905060080
1999-01-6 Boeing GTSTRUDL compute fatigue 03/31/1999 9904060386
1999-01-5 Boeing GTSTRUDL print fatigue member data 03/19/1999 9903190115
1999-01-4 Boeing GTSTRUDL fatigue analysis 03/15/1999 9903260150
1999-01-3 Boeing GTSTRUDL superstructure 03/08/1999 9903180200
1999-01-2 Boeing GTSTRUDL stiffness analysis 02/08/1999 9902190238
1999-01-1 Boeing ANSYS integration scheme 01/25/1999 9902050085
1999-01-0 Boeing GTSTRUDL girder 12/02/1998 9812100007

Page Last Reviewed/Updated Thursday, March 19, 2020