Part 21 Report - 1999-100
| LICENSEE: | SWAGELOK COMPANY | ||
| SITE: | SWAGELOK COMPANY | EN NUMBER: | 35329 |
| DOCKET: | EVENT DATE: | 01-28-99 | |
| RX TYPE: | EVENT TIME: | ||
| VENDORS: | NOTIFY DATE: | 01-29-99 | |
| EMERGENCY CLASS: | N/A REGION: 3 STATE: OH | TIME: 16:04 | |
| OPS OFFICER: | CHAUNCEY GOULD | ||
| 10 CFR SECTION: | CCCC UNSPECIFIED PARAGRAPH | ||
THE SWAGELOK COMPANY IS SUBMITTING A POSSIBLE 10CFR PART 21 NOTIFICATION BECAUSE OF A POSSIBLE MATERIAL DEFECT IN A SWAGELOK PIPE FITTING TEE, PART # SS-6-T. THE DEFECT IS A CRACK IN THE CENTER OF THE FORGING. THEY ARE CONTINUING THEIR ANALYSIS OF THE PART.
THIS PART WAS SUPPLIED TO PUBLIC SERVICE ELECTRIC & GAS(20 PCS.) IN HANCOCKS BRIDGE N.J. AND SOUTH CAROLINA ELECTRIC & GAS CO., VC SUMMER STATION(3 PCS.) THE PRODUCT ID IS R27GE0123B.