Part 21 Report - 1999-019
ACCESSION #: 9906220141
BOEING
Shared Services Group
P.O. Box 3707
Seattle, WA 98124-2207
June 15, 1999
G-1151-SJA-98-265
Document Control Desk
United States Nuclear Regulatory Commission
Washington, D.C. 20555
Reference: | a) | Boeing Letter G-1151-RSO-92-365 dated August 31, 1992; R. S. Orr to the NRC Operations Center |
| b) | NRC Letter Docket No. 99901227 dated August 12, 1992; L. J. Norrholm to R. S. Orr; Subject: Response to 10 CFR 21Inquiry |
Dear Sir or Madam:
In accordance with the reference correspondence and 10 CFR 21, Boeing is sending the NRC the attached error notice(s) received from our former software suppliers. Because of unknown current addresses, the following former customers were not notified:
Reactor Controls, Inc.
Echo Energy Consultants, Inc.
Nuclear Applications and Systems Analysis Company (Japan)
Nuclear Power Services
Error notices have been sent to our other former customers.
| Very truly yours, Sandra J. Andrews Nuclear Administrator Phone: (425) 865-6248 FAX: (425) 865-4851 Mail Stop: 7A-33, or e-mail: Sandra.J.Andrews@Boeing.com |
Enclosure(s): GTSTRUDL Program Report Form 99.12
Georgia Institute of Technology | GT STRUDL "Registered Trademark" |
June 1, 1999
JUN 09 1999
Attention: Nuclear Administrator
Boeing Information & Support Services
P.O. Box 24346, M/S 7A-33
Seattle, Washington 98124-0346
RE: GT STRUDL
Dear Sir or Madam:
Enclosed please find copies of GTSTRUDL PROGRAM REPORT FORM 99.12, and a GTSTRUDL QA CUSTOMER ACKNOWLEDGEMENT FORM. Please sign and return the GTSTRUDL QA CUSTOMER ACKNOWLEDGEMENT FORM to acknowledge receipt of the GTSTRUDL Program Report.
Thank you for reviewing the Program Report and for returning the Acknowledgement Form.
| Best regards, CASE Center David C. Key Configuration Control Manager |
Enclosures
Computer Aided Structural Engineering Center | Phone: (404) 894-2260 |
School of Civil & Environmental Engineering | Fax: (404) 894-8014 |
Atlanta, Georgia 30332-0355 USA | casec@ce.gatech.edu |
A Unit of the University System of Georgia
GTSTRUDL Program Report Form
FROM: | Computer-Aided Structural Engineering Center Georgia Institute of Technology Atlanta, Georgia 30332-0355 |
| |
SEVERITY LEVEL: |
x | URGENT | Problem results in incorrect answers which may not be apparent or job aborts and cannot be recovered within the session or job. |
| SERIOUS | Problem results in incorrect answers which are obvious or problem prevents completion of a particular user's task. |
| MINOR | Problem can be worked around or problem poses high frustration factor. |
| INFORMATIVE | Documentation error, program usage tip, user inconveniences. |
| | |
Date Problem Confirmed | May 25, 1999 | |
Date Notification Sent | | |
Computers | All | |
Operating System | All | |
Versions: | 97.01 and 98.01 | |
Target Release for Correction: | 99.01 | |
| | |
| | Mgr. ASD |
Signature | | Title |
| | |
R & D Division | | |
| | |
Michael H. Swanger | | |
Typed or Printed Name | | Date of Signature |
| | |
Signature | | Title |
| | |
Professional Services Division | | |
| | |
Typed or Printed Name | | Date of Signature |
| | |
Rev. 2.2
GTSTRUDL Program Report Form
(Continued)
DESCRIPTION:
The PRINT STRUCTURAL DATA and PRINT MEMBER/ELEMENT INCIDENCES commands will abort if rigid bodies having more than 30 incidences are present in the model. There is no workaround for this problem.
Applicable Reference Manual Sections
1. | Problem Description Data Output - |
| The PRINT Command | Section 2.1.14.2, Volume 1, GTSTRUDL Reference Manual |
2. | Joint Constraints - Joint Ties and Rigid Bodies | Section 2.6.4, Volume 3, GTSTRUDL Reference Manual |
Rev. 2.2
*** END OF DOCUMENT ***