Skip to main content

Part 21 Report - 1999-019

ACCESSION #: 9906220141


BOEING

Shared Services Group
P.O. Box 3707
Seattle, WA 98124-2207

June 15, 1999

G-1151-SJA-98-265

Document Control Desk
United States Nuclear Regulatory Commission
Washington, D.C. 20555

Reference: a) Boeing Letter G-1151-RSO-92-365 dated August 31, 1992; R. S. Orr to the NRC Operations Center
b) NRC Letter Docket No. 99901227 dated August 12, 1992; L. J. Norrholm to R. S. Orr; Subject: Response to 10 CFR 21Inquiry

Dear Sir or Madam:

In accordance with the reference correspondence and 10 CFR 21, Boeing is sending the NRC the attached error notice(s) received from our former software suppliers. Because of unknown current addresses, the following former customers were not notified:

Reactor Controls, Inc.
Echo Energy Consultants, Inc.
Nuclear Applications and Systems Analysis Company (Japan)
Nuclear Power Services

Error notices have been sent to our other former customers.

Very truly yours,

Sandra J. Andrews
Nuclear Administrator
Phone: (425) 865-6248
FAX: (425) 865-4851
Mail Stop: 7A-33, or
e-mail: Sandra.J.Andrews@Boeing.com

Enclosure(s): GTSTRUDL Program Report Form 99.12

Georgia Institute of Technology GT STRUDL "Registered Trademark"

June 1, 1999

JUN 09 1999

Attention: Nuclear Administrator
Boeing Information & Support Services
P.O. Box 24346, M/S 7A-33
Seattle, Washington 98124-0346

RE: GT STRUDL

Dear Sir or Madam:

Enclosed please find copies of GTSTRUDL PROGRAM REPORT FORM 99.12, and a GTSTRUDL QA CUSTOMER ACKNOWLEDGEMENT FORM. Please sign and return the GTSTRUDL QA CUSTOMER ACKNOWLEDGEMENT FORM to acknowledge receipt of the GTSTRUDL Program Report.

Thank you for reviewing the Program Report and for returning the Acknowledgement Form.

Best regards,

CASE Center

David C. Key
Configuration Control Manager

Enclosures

Computer Aided Structural Engineering Center Phone: (404) 894-2260
School of Civil & Environmental Engineering Fax: (404) 894-8014
Atlanta, Georgia 30332-0355 USA casec@ce.gatech.edu

A Unit of the University System of Georgia


GTSTRUDL Program Report Form

GPRF No.: 99.12
DATE:
FROM: Computer-Aided Structural Engineering Center
Georgia Institute of Technology
Atlanta, Georgia 30332-0355
 
SEVERITY LEVEL:
 x  URGENT Problem results in incorrect answers which may not be apparent or job aborts and cannot be recovered within the session or job.
    SERIOUS Problem results in incorrect answers which are obvious or problem prevents completion of a particular user's task.
    MINOR Problem can be worked around or problem poses high frustration factor.
    INFORMATIVE Documentation error, program usage tip, user inconveniences.
 
Date Problem Confirmed May 25, 1999
Date Notification Sent
Computers All
Operating System All
Versions: 97.01 and 98.01
Target Release for Correction: 99.01
 
Mgr. ASD
Signature Title
 
R & D Division
 
Michael H. Swanger
Typed or Printed Name Date of Signature
 
Signature Title
 
Professional Services Division
 
Typed or Printed Name Date of Signature

Rev. 2.2


GTSTRUDL Program Report Form
(Continued)

GPRF No.: 99.12
DATE:

DESCRIPTION:

The PRINT STRUCTURAL DATA and PRINT MEMBER/ELEMENT INCIDENCES commands will abort if rigid bodies having more than 30 incidences are present in the model. There is no workaround for this problem.

Applicable Reference Manual Sections

1. Problem Description Data Output -
The PRINT Command Section 2.1.14.2, Volume 1, GTSTRUDL Reference Manual
2. Joint Constraints - Joint Ties and Rigid Bodies Section 2.6.4, Volume 3, GTSTRUDL Reference Manual

Rev. 2.2


*** END OF DOCUMENT ***