Home > NRC Library > ADAMS Public Documents
Response to Requests for Additional Information Concerning Davis-Besse Nuclear Power Station Third Ten-Year Interval Inservice Inspection Program.
Accession Number: ML013600132
Date Released: Monday, January 7, 2002
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML013480471 - Response to Requests for Additional Information Concerning Davis-Besse Nuclear Power Station Third Ten-Year Interval Inservice Inspection Program. (93 page(s), 11/27/2001)
- ML013480444 - Revision 5 to Drawing ISID2-001, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Diagram, Inservice Inspection Boundary Diagram Index/Legend Sheet." (1 page(s), 8/21/2000)
- ML013480453 - Revision 5 to Drawing ISID2-003A, Davis-Besse Nuclear Power Station, Unit 1 Inservice Inspection Diagram, Main Steam & Reheat System Sheet 1." (1 page(s), 6/12/2000)
- ML013480455 - Revision 7 to Drawing ISID2-003C, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Diagram Main Steam & Reheat System Sheet 3." (1 page(s), 5/31/1996)
- ML013480462 - Revision 5 to Drawing ISID2-006D, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Diagram Auxiliary Feedwater System." (1 page(s), 11/7/1995)
- ML013480467 - Revision 5 to Drawing ISID2-007A, "Davis-Besse Nuclear Power Station, Units 1, Inservice Inspection Diagram, Steam Generator Secondary System." (1 page(s), 6/12/2000)
- ML013480475 - Revision 4 to Drawing ISID2-007B, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Diagram, Steam Generator Secondary System." (1 page(s), 5/31/1996)
- ML013480482 - Revision 3 to Drawing ISID2-010C, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Diagram, Make-Up Water Treatment System." (1 page(s), 8/21/2000)
- ML013480492 - Revision 3 to Drawing ISID2-015A, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Diagram Instrument Air System." (1 page(s), 8/21/2000)
- ML013480494 - Revision 3 to Drawing ISID2-015D, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Diagram, Station Air System." (1 page(s), 8/21/2000)
- ML013480501 - Revision 3 to Drawing ISID2-017A, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Diagram, Diesel Generators." (1 page(s), 6/12/2000)
- ML013480514 - Revision 8 to Drawing ISID2-017B, "Davise-Besse Nuclear Power Station, Unit 1, Inservice Inspection Diagram, Diesel Generators Air Start." (1 page(s), 8/21/2000)
- ML013480517 - Revision 5 to Drawing ISID2-019, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Diagram, Nitrogen Supply System." (1 page(s), 8/21/2000)
- ML013480528 - Revision 8 to Drawing ISID2-029B, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Diagram, Auxiliary Building Radwaste, Fuel Handling & Access Control Areas, Sheet 2." (1 page(s), 8/21/2000)
- ML013480537 - Revision 3 to Drawing ISID2-029C, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Diagram, Containment & Penetration Rooms Sheet 2." (1 page(s), 8/5/1998)
- ML013480546 - Revision 3 to Drawing ISID2-029D, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Diagram, Containment & Penetration Rooms Sheet 3." (1 page(s), 2/16/1994)
- ML013480551 - Revision 6 to Drawing ISID2-029E, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Diagram, Containment & Penetration Rooms Sheet 4." (1 page(s), 8/21/2000)
- ML013480555 - Revision 9 to Drawing ISID2-030A, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Diagram, Reactor Coolant System." (1 page(s), 3/2/2001)
- ML013480556 - Revision 3 to Drawing ISID2-031A, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Diagram, Make-Up & Purification System." (1 page(s), 7/14/1997)
- ML013480579 - Revision 3 to Drawing ISID2-031B, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Diagram, Make-Up & Purification System." (1 page(s), 8/13/1996)
- ML013480585 - Revision 6 to Drawing ISID2-031C, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Diagram, Make Up & Purification System." (1 page(s), 6/12/2000)
- ML013480587 - Revision 8 to Drawing ISID2-033A, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Diagram, high Pressure Injection." (1 page(s), 3/2/2001)
- ML013480589 - Revision 9 to Drawing ISID2-033B, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Diagram, Decay Heat Train 1." (1 page(s), 8/21/2000)
- ML013480593 - Revision 7 to Drawing ISID2-033C, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Diagram, Decay Heat Train 2." (1 page(s), 8/21/2000)
- ML013480595 - Revision 7 to Drawing ISID2-034, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Diagram Emergency, Core Cooling System CTMT Spray & Core Flooding Systems." (1 page(s), 8/21/2000)
- ML013510004 - Revision 3 to Drawing ISID2-035, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Diagram, Spent Fuel Pool Cooling System." (1 page(s), 8/21/2000)
- ML013510007 - Revision 7 to Drawing ISID2-036A, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Diagram, Component Cooling Water System." (1 page(s), 4/24/1998)
- ML013510010 - Revision 8 to Drawing ISID2-036B, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Diagram, Component Cooling Water System." (1 page(s), 8/21/2000)
- ML013510017 - Revision 10 to Drawing ISID2-036C, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Diagram, Component Cooling Water System." (1 page(s), 6/12/2000)
- ML013510022 - Revision 6 to Drawing ISID2-040A, "Davis-Besse Nuclear Power Station, Unit 1, Reactor Coolant System Details." (1 page(s), 8/21/2000)
- ML013510025 - Drawing ISID2 040D, Revision 3, "INSERVICE INSPECTION DIAGRAM, REACTOR COOLANT PUMP & MOTOR." (1 page(s), 8/20/1997)
- ML013510053 - Drawing ISID2 041A, Revision 3, "INSERVICE INSPECTION DIAGRAM, SERVICE WATER PUMPS AND SECONDARY SERVICE WATER SYSTEM. (1 page(s), 2/23/1996)
- ML013510060 - Drawing ISID2 041B, Revision 14, "INSERVICE INSPECTION DIAGRAM, PRIMARY SERVICE WATER SYSTEM." (1 page(s), 6/12/2000)
- ML013510065 - Drawing ISID2 041C, Revision 10, "INSERVICE INSPECTION DIAGRAM, SERVICE WATER SYSTEM FOR CONTAINMENT AIR COOLERS." (1 page(s), 4/24/1998)
- ML013510070 - Drawing ISID2 046, Revision 4, "INSERVICE INSPECTION DIAGRAM, STATION DRAINAGE SYSTEMS." (1 page(s), 7/10/1998)
- ML013510075 - Drawing ISID2 023, Revision 3, "INSERVICE INSPECTION DIAGRAM, CONTAINMENT LEAK-RATE TEST DIAGRAM." (1 page(s), 7/10/1998)
- ML013510080 - Drawing ISIM2 200, Revision 2, "INSERVICE INSPECTION ISOMETRIC DRAWING INDEX LEGEND SHEET." (1 page(s), 3/2/2001)
- ML013510084 - Drawing ISIM2 203A, Revision 2, "INSERVICE INSPECTION ISOMETRIC, MAIN STEAM SYSTEM CONTAINMENT BUILDING STEAM GENERATOR 1 - 1." (1 page(s), 9/22/1992)
- ML013510089 - Drawing ISIM2 203B, Revision 1, "INSERVICE INSPECTION ISOMETRIC MAIN STEAM SYSTEM CONTAINMENT BUILDING STEAM GENERATOR 1 2." (1 page(s), 11/27/2001)
- ML013510094 - Drawing ISIM2 203F, Revision 3, "INSERVICE INSPECTION ISOMETRIC, MAIN STEAM SYSTEM SUPPLY TO AUX FEED PUMP TURBINE NO. 1 1." (1 page(s), 5/17/1993)
- ML013510097 - Drawing ISIM2 203H, Revision 4, "INSERVICE INSPECTION ISOMETRIC, MAIN STEAM SYSTEM, SUPPLY TO AUX FEED PUMP TURBINE NO. 1 2 EXHAUST." (1 page(s), 2/23/1996)
- ML013510542 - Drawing ISIM2 203J, Rev 3, "INSERVICE INSPECTION ISOMETRIC MAIN STEAM SYSTEM, MAIN STEAM CROSSOVERS," Sheet 1. (1 page(s), 6/12/2000)
- ML013510550 - Drawing ISIM2 203J, Rev 2, "INSERVICE INSPECTION ISOMETRIC, MAIN STEAM SYSTEM, MAIN STEAM CROSSOVERS," Sheet 2. (1 page(s), 5/9/1993)
- ML013510554 - Drawing ISIM2 203K, Rev 1, "INSERVICE INSPECTION ISOMETRIC, MAIN STEAM SYSTEM, AUX FEED PUMP TURBINE EXHAUST." (1 page(s), 1/3/1992)
- ML013510558 - Drawing ISIM2 206F, Rev 1, "INSERVICE INSPECTION ISOMETRIC, AUXILIARY FEEDWATER SYSTEM, AUX FEED PUMP DISCH TO STEAM GENERATOR," Sheet 1. (1 page(s), 12/10/1991)
- ML013510562 - Drawing ISIM2 206F, Rev 1 "INSERVICE INSPECTION ISOMETRIC, AUXILIARY FEEDWATER SYSTEM, AUX FEED PUMP DISCH TO STEAM GENERATORS," Sheet 2. (1 page(s), 12/10/1991)
- ML013510573 - Drawing ISIM2 206F, Rev 1, "INSERVICE INSPECTION ISOMETRIC AUXILIARY FEEDWATER SYSTEM, AUX FEED PUMP DISCH TO STEAM GENERATORS," Sheet 3. (1 page(s), 2/4/1992)
- ML013510574 - Drawing ISIM2 206F, Rev 1 "INSERVICE INSPECTION ISOMETRIC AUXILIARY FEEDWATER SYSTEM AUX FEED PUMP DISCH TO STEAM GENERATORS," Sheet 4. (1 page(s), 12/10/1991)
- ML013510578 - Drawing ISIM2 206F, Rev 1, "INSERVICE INSPECTION ISOMETRIC AUXILIARY FEEDWATER SYSTEM AUX FEED PUMP DISCH TO STEAM GENERATORS," Sheet 5. (1 page(s), 3/2/2001)
- ML013510582 - Drawing ISIM2 206G, Rev 3, "INSERVICE INSPECTION ISOMETRIC CONDENSATE & SERVICE WATER SYSTEMS AUX & START UP FEED PUMPS SUCTION & RECIRC." (1 page(s), 3/2/2001)
- ML013510588 - Drawing ISIM2 206N, Rev 1 " INSERVICE INSPECTION ISOMETRIC AUXILIARY FEEDWATER SYSTEM CONTAINMENT." (1 page(s), 12/12/1991)
- ML013510593 - Drawing ISIM2 206Q, Rev 1 "INSERVICE INSPECTION ISOMETRIC CONDENSATE SYSTEM MOTOR DRIVEN FEED PUMP P 241 DISCHARGE." (1 page(s), 1/8/1992)
- ML013510603 - Drawing ISIM2 207A, Rev 1 "INSERVICE INSPECTION ISOMETRIC STEAM GENERATOR DRAIN SYSTEM CONTAINMENT BUILDING.' (1 page(s), 12/10/1991)
- ML013510608 - Drawing ISIM2 207C, Rev 2 "INSERVICE INSPECTION ISOMETRIC MAIN FEEDWATER SYSTEM AUXILIARY AND CONTAINMENT BUILDINGS," Sheet 1. (1 page(s), 7/7/1993)
- ML013510623 - Drawing ISIM2 207C, Rev 2 "INSERVICE INSPECTION ISOMETRIC MAIN FEEDWATER SYSTEM AUXILIARY AND CONTAINMENT BUILDING," Sheet 2. (1 page(s), 6/11/1993)
- ML013510627 - Drawing ISIM2 207E, Rev 1 "INSERVICE INSPECTION ISOMETRIC STEAM GENERATOR NO 1 1 DRAIN BLOWDOWN SYSTEM CONTAINMENT BUILDING." (1 page(s), 1/13/1992)
- ML013520014 - Drawing ISIM2 207F, Rev 1 "INSERVICE INSPECTION ISOMETRIC STEAM GENERATOR NO. 1 1 DRAIN BLOWDOWN SYSTEM AUXILIARY AND TURBINE BUILDING." (1 page(s), 4/9/1992)
- ML013520016 - Drawing ISIM2 207G, Rev 1, "INSERVICE INSPECTION ISOMETRIC STEAM GENERATOR NO. 1 2 DRAIN BLOWDOWN SYSTEM AUXILIARY AND TURBINE BUILDING." (1 page(s), 12/10/1991)
- ML013520020 - Drawing ISIM2 210E, Rev 1 "INSERVICE INSPECTION ISOMETRIC MAKE-UP WATER TREATMENT SYSTEM AUXILIARY BUILDING." (1 page(s), 12/12/1991)
- ML013520022 - Drawing ISIM2 210H, Rev 2 "INSERVICE INSPECTION ISOMETRIC MAKE UP WATER TREATMENT SYSTEM CONTAINMENT BUILDING." (1 page(s), 3/23/1993)
- ML013520023 - Revision 2 to Drawing ISIM2-217A, Sheet 1, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Emergency diesel Generators Fuel Oil System." (1 page(s), 2/4/1992)
- ML013520028 - Revision 1 to Drawing ISIM2-217A, Sheet 2, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Emergency Diesel Generators Fuel Oil System." (1 page(s), 2/5/1992)
- ML013520046 - Revision 3 to Drawing ISIM2-229, Sheet 1, "Davis-Besse Nuclear Power Station, Unit 1 Inservice Inspection Isometric Hydrogen Dilution System & Miscellaneous Containment Penetrations Auxiliary & Containment Buildings." (1 page(s), 8/5/1998)
- ML013520048 - Revision 3 to Drawing ISIM2-229, Sheet 2, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Hydrogen Dilution System & Miscellaneous Containment Penetrations Auxiliary & Containment Buildings." (1 page(s), 6/27/1994)
- ML013520051 - Revision 2 to Drawing ISIM2-229, Sheet 3, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Integrated Leak Rate Test Line Auxiliary & Containment Buildings." (1 page(s), 6/27/1994)
- ML013520053 - Revision 2 to Drawing ISIM2-230A, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Pressurizer Relief System Containment Building." (1 page(s), 11/11/1999)
- ML013520058 - Revision 3 to Drawing ISIM2-230B, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Reactor Coolant System." (1 page(s), 3/8/2001)
- ML013520061 - Revision 5 to Drawing ISIM2-230C, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Pressurizer Spray & Surge Lines Containment Building." (1 page(s), 3/8/2001)
- ML013520065 - Revision 2 to Drawing ISIM2-230D, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric R. V. Head to Hot Leg Vent Line Containment Building." (1 page(s), 6/17/1993)
- ML013520068 - Revision 1 to Drawing ISIM2-231A, "Davis-Besse Nuclear Power Station, Unit 1 Inservice Inspection Isometric Purification R. C. Letdown System Containment Building." (1 page(s), 5/22/1992)
- ML013520072 - Revision 2 to Drawing ISIM2-231B, Sheet 1, "Davis-Besse Nuclear Power Station, Unit 1 Inservice Inspection Isometric Make-Up & Purification System Auxiliary Building." (1 page(s), 8/24/1993)
- ML013520082 - Revision 1 to Drawing ISIM2-231B, Sheet 2, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Make-Up & Purification System Auxiliary Building." (1 page(s), 4/13/1992)
- ML013520085 - Revision 1 to Drawing ISIM2-231B, Sheet 3, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Make-Up & Purification System Auxiliary Building." (1 page(s), 5/22/1992)
- ML013520093 - Revision 1 to Drawing ISIM2-231C, Sheet 4, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Make-Up & Purification System Auxiliary Building." (1 page(s), 1/8/1992)
- ML013520097 - Revision 1 to Drawing ISIM-231D, Sheet 1 "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Make-Up & Purification System Auxiliary Building ." (1 page(s), 4/22/1992)
- ML013520102 - Revision 1 to Drawing ISIM2-231D, Sheet 2, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Make-Up & Purification System Auxiliary Building." (1 page(s), 2/5/1992)
- ML013520107 - Revision 2 to Drawing ISIM2-231D, Sheet 3, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Make-Up & Purification System Auxiliary building ." (1 page(s), 9/25/1992)
- ML013520110 - Revision 1 to Drawing ISIM2-231E, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Make-Up & Purification System Auxiliary." (1 page(s), 4/13/1992)
- ML013520121 - Revision 2 to Drawing ISIM2-233A, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Emergency Core Cooling System Borated Water Supply." (1 page(s), 9/25/1992)
- ML013520134 - Revision 4 to Drawing ISIM2-233B, Sheet 1, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Emergency Core Cooling Systems Pump Suction Pipiing." (1 page(s), 3/8/2001)
- ML013520140 - Revision 3 to Drawing ISIM2-233B, Sheet 2, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Emergency Core Cooling Systems Pump Suction Piping." (1 page(s), 3/8/2001)
- ML013540004 - Revision 2 to Drawing ISIM2-233C, Sheet 1, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Decay Heat Removal System CTMT Auxiliary Building Normal Cooldown." (1 page(s), 7/11/2000)
- ML013540005 - Revision 2 to Drawing ISIM2-233C, Sheet 2, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Decay Heat Removal System CTMT Auxiliary Building Normal Cooldown." (1 page(s), 9/27/1992)
- ML013540006 - Revision 5 to Drawing ISIM2-233D, Sheet 1, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric H. P. Injection System Auxiliary Building." (1 page(s), 8/21/2000)
- ML013540009 - Revision 1 to Drawing ISIM2-233D, Sheet 2, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric H. P. Injection System Auxiliary Building." (1 page(s), 12/10/1991)
- ML013540010 - Revision 6 to Drawing ISIM2-233D, Sheet 3, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric H. P. Injection System Auxiliary Building." (1 page(s), 7/31/2001)
- ML013540032 - Revision 1 to Drawing ISIM2-233D, Sheet 4, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric H. P. Injection System Auxiliary Building." (1 page(s), 7/11/2000)
- ML013540034 - Revision 1 to Drawing ISIM2-233E, Sheet 1, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric H. P. Injection System CTMT Building." (1 page(s), 12/12/1991)
- ML013540038 - Revision 1 to Drawing ISIM2-233E, Sheet 2, "Davis-Besse Power Station, Unit 1, Inservice Inspection Isometric H. P. Injection System CTMT Buildging." (1 page(s), 9/17/1990)
- ML013540040 - Revision 4 to Drawing ISIM2-233F, Sheet 1, "Davis-Besse Nuclear Power Plant Station, Unit 1, Inservice Inspection Isometric Low Pressure Injection System Auxiliary Building." (1 page(s), 8/21/2000)
- ML013540047 - Revision 3 to Drawing ISIM2-233F, Sheet 2, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Low Pressure Injection System Auxiliary Building." (1 page(s), 11/3/1993)
- ML013540053 - Revision 1 to Drawing ISIM2-233F, Sheet 3, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Injection Isometric Low Pressure Injection System Auxiliary Building." (1 page(s), 5/22/1992)
- ML013540062 - Revision 1 to Drawing ISIM2-233G, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Refueling Canal & In-Core Tank Fill & Drain System Containment Building." (1 page(s), 2/4/1992)
- ML013540064 - Revision 2 to Drawing ISIM2-233H, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Make-Up & Purification System Auxiliary Building - Sheet 9." (1 page(s), 9/25/1992)
- ML013540067 - Revision 2 to Drawing ISIM2-234A, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric L. P. Injection Isometric L. P. Injection-Core Flooding System CTMT Building." (1 page(s), 9/25/1992)
- ML013540076 - Revision 1 to Drawing ISIM2-234B, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Containment Spray System Containment Building, Sheet 1." (1 page(s), 5/22/1992)
- ML013540078 - Revision 1 to Drawing ISIM2-234B, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Containment Spray System Containment Building, Sheet 2." (1 page(s), 3/6/1992)
- ML013540082 - Revision 2 to Drawing ISIM2-234B, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Containment Spray System Containment Building, Sheet 3." (1 page(s), 7/25/1997)
- ML013540090 - Revision 2 to Drawing ISIM2-234C, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Containment Spray System Auxiliary building Pump 1- 1 Discharge." (1 page(s), 8/24/1998)
- ML013540093 - Revision 0 to Drawing ISIM2-234D, Sheet 1 of 2, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Containment Spray System & Spent Fuel Pool Cooling System Auxiliary Building Pump 1 - 2 Discharge." (1 page(s), 9/17/1990)
- ML013540095 - Revision 1 to Drawing ISIM2-234D, Sheet 2, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Containment Spray System & Spent Fuel Pool Cooling System Auxiliary Building Pump 1 - 2 Discharge." (1 page(s), 5/22/1992)
- ML013540100 - Revision 1 to Drawing ISIM2-235A, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Spent Fuel Pool Cooling System Auxiliary Building - Area 7, Sheet 1." (1 page(s), 9/17/1990)
- ML013540104 - Revision 1 to Drawing ISIM2-235A, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Spent Fuel Pool Cooling System Auxiliary Building - Area 7, Sheet 2." (1 page(s), 3/10/1992)
- ML013540110 - Revision 1 to Drawing ISIM2-235A, "Davis-Besse Nuclear Power Station, Unit 1 Inservice Inspection Isometric Spent Fuel Pool Cooling System Auxiliary Building - Area 7, Sheet 3." (1 page(s), 1/22/1992)
- ML013540122 - Revision 1 to Drawing ISIM2-235A, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Spent Fuel Pool Cooling System Auxiliary Building - Area 7, Sheet 4." (1 page(s), 3/16/1992)
- ML013540128 - Revision 5 to Drawing ISIM2-235B, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Spent Fuel Pool Cooling System Auxiliary Building Area 8, Sheet 1." (1 page(s), 7/31/2001)
- ML013540131 - Revision 2 to Drawing ISIM2-235B, Sheet 2, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Spent Fuel Pool Cooling System Auxiliary Building Area 8, Sheet 2." (1 page(s), 11/10/1992)
- ML013540140 - Revision 1 to Drawing ISIM2-236A "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Component Cooling Water System Auxiliary Building, Sheet 1." (1 page(s), 5/22/1992)
- ML013540147 - Revision 1 to Drawing ISIM2-236A, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Component Cooling Water System Auxiliary Building, Sheet 2." (1 page(s), 3/2/1992)
- ML013540152 - Revision 4 to Drawing ISIM2-236B, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Component Cooling System Auxiliary Building EL, Sheet 1." (1 page(s), 6/27/1994)
- ML013540161 - Revision 1 to Drawing ISIM2-236B, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Component Cooling Water System Auxiliary Building EL, Sheet 2." (1 page(s), 3/16/1992)
- ML013540169 - Revision 3 to Drawing ISIM2-236C, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Component Cooling System Heat Exchangers Inlets EL, Sheet 1." (1 page(s), 2/12/1996)
- ML013600002 - Revision 2 to Drawing ISIM2-236C, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Component Cooling System Heat Exchangers Inlets EL, Sheet 2." (1 page(s), 8/21/2000)
- ML013600003 - Revision 1 to Drawing ISIM2-236C, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Component Cooling System Heat Exchangers Inlets EL, Sheet 3." (1 page(s), 1/21/1992)
- ML013600005 - Revision 3 to Drawing ISIM2-236D, "Davis-Besse Nuclear Power Station, Unit 1 Inservice Inspection Isometric Component Cooling System C. C. Heat Exchangers Outlet Piping EL, Sheet 1." (1 page(s), 10/1/1993)
- ML013600006 - Revision 3 to Drawing ISIM2-236D, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Component Cooling System C. C. Heat Exchangers Outlet Piping EL, Sheet 2." (1 page(s), 7/11/2000)
- ML013600007 - Revision 1 to Drawing ISIM2-236D, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Component Cooling System C. C. Heat Exchangers Outlet Piping EL, Sheet 3." (1 page(s), 2/6/1992)
- ML013600008 - Revision 4 to Drawing ISIM2-233E, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Component Cooling Water System CTMT Building, Sheet 1." (1 page(s), 7/11/2000)
- ML013600010 - Revision 2 to Drawing ISIM2-236E, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric, Component Cooling Water System CTMT Building, Sheet 2." (1 page(s), 7/25/1997)
- ML013600013 - Revision 2 to Drawing ISIM2-236F, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric, Component Cooling Water System Containment Building (P36-4), Sheet 1." (1 page(s), 8/6/1993)
- ML013600016 - Drawing ISIM2-236F, Revision 3, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Component Cooling Water System Containment Building (P36-3)." Sheet 2. (1 page(s), 7/19/1993)
- ML013600018 - Drawing ISIM2-236F, Revision 3, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Component Cooling Water System Containment Building (P36-2)." Sheet 3. (1 page(s), 6/12/2000)
- ML013600025 - Drawing ISIM2-236F, Revision 2 "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Component Cooling Water System Containment Building (P36-1)." Sheet 4. (1 page(s), 7/19/1993)
- ML013600028 - Drawing ISIM2-236H, Revision 1, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Component Cooling System Supply & Return Emergency Diesel Generators." Sheet 1. (1 page(s), 3/16/1992)
- ML013600030 - Drawing ISIM2-236H, Revision 2, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Component Cooling System Supply & Return Emergency Diesel Generators." Sheet 2. (1 page(s), 7/16/1998)
- ML013600034 - Drawing ISIM2-236H, Revision 1, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Component Cooling System Supply & Return Emergency Diesel Generators." Sheet 3. (1 page(s), 3/16/1992)
- ML013600036 - Drawing ISIM2-236H, Revision 1, "Davis-Besse Nuclear Power Station, Unit 1 Inservice Inspection Isometric Component Cooling System Supply & Return Emergency Diesel Generators." Sheet 4. (1 page(s), 9/17/1990)
- ML013600037 - Drawing ISIM2-236J, Revision 1, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Component Cooling System Embedded Piping-Control Room Floor El. 623 feet 0 inches." (1 page(s), 3/16/1992)
- ML013600039 - Drawing ISIM2-240A, Revision 1, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Reactor Coolant Drain System Containment Building." (1 page(s), 4/9/1992)
- ML013600042 - Drawing ISIM2-240B, Revision 2, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Quench Tank Drain System Containment - Auxiliary Building." (1 page(s), 7/10/1998)
- ML013600047 - Drawing ISIM2-240C, Revision 1, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Reactor Coolant Drain & Gaseous Radwaste System Auxiliary Building." (1 page(s), 6/10/1992)
- ML013600050 - Drawing ISIM2-240D, Revision 1, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Coolant System Details CTMT Building." (1 page(s), 5/21/1992)
- ML013600052 - Drawing ISIM2-241A, Revision 5, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Service Water System Coolers & Return Line." (1 page(s), 7/25/2001)
- ML013600053 - Drawing ISIM2-241B, Revision 3, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Service Water System Valve Rooms & Tunnel." Sheet 1. (1 page(s), 6/12/2000)
- ML013600055 - Drawing ISIM2-241B, Revision 2, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Service Water System Valve Rooms & Tunnel." Sheet 2. (1 page(s), 2/3/1995)
- ML013600059 - Drawing ISIM2-241C, Revision 1, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Service Water System Auxiliary Building-Supply Piping." Sheet 1. (1 page(s), 5/21/1992)
- ML013600068 - Drawing ISIM2-241C, Revision 3, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Service Water System Auxiliary Building-Supply Piping." Sheet 2. (1 page(s), 6/27/1994)
- ML013600072 - Drawing ISIM2-241D, Revision 3, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Service Water System Auxiliary Building - Return Piping." Sheet 3. (1 page(s), 6/27/1994)
- ML013600075 - Drawing ISIM2-241D, Revision 5, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Service Water System Auxiliary Building - Return Piping." (1 page(s), 6/12/2000)
- ML013600077 - Drawing ISIM2-241E, Revision 4, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Service Water System CTMT Air Cooler 1 - 1." (1 page(s), 6/27/1994)
- ML013600081 - Drawing ISIM2-241F, Revision 4, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Service Water System CTMT - Air Cooler 1 - 2." (1 page(s), 6/27/1994)
- ML013600086 - Drawing ISIM2-241G, Revision 4, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Service Water System CTMT Air Cooler 1 - 3." (1 page(s), 8/25/1994)
- ML013600088 - Drawing ISIM2-241H, Revision 6, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Service Water System ECCS Room Coolers Supply & Return." Sheet 1. (1 page(s), 6/12/2000)
- ML013600090 - Revision 3 to Drawing ISIM2-241H, Sheet 2, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Service Water system ECCS Room Coolers Supply & Return." (1 page(s), 6/12/2000)
- ML013600095 - Revision 6 to Drawing ISIM2-241H, Sheet 3, "Davis-Besse Nuclear Power Station, Unit 1 Inservice Inspection Isometric Service Water System ECCS Room Coolers Supply & Return." (1 page(s), 6/12/2000)
- ML013600104 - Revision 4 to Drawing ISIM2-241H, Sheet 4, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Service Water System ECCS Room Coolers Supply & Return." (1 page(s), 6/12/2000)
- ML013600107 - Revision 1 to Drawing ISIM2-241L, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Service Water System Auxiliary Building-Return Piping." (1 page(s), 5/21/1992)
- ML013600112 - Revision 1 to Drawing ISIM2-241M, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Service Water System Auxiliary Building-Supply to Motor Driven Feed Pump." (1 page(s), 5/21/1992)
- ML013600117 - Revision 2 to Drawing ISIM2-246A, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Liquid Radwaste System Normal Sump Pumps Discharge - CTMT B Auxiliary Buildings. (1 page(s), 9/10/1998)
- ML013600120 - Revision 1 to Drawing ISIM2-268D, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Isometric Emergency Diesel Generator Air Intake & Exhaust." (1 page(s), 5/13/1996)
- ML013600126 - Revision 0 to Drawing ISIM2-E371, "Davis-Besse Nuclear Power Station, Unit 1, Inservice Inspection Drawing Electrical Penetration Arrangement Containment Vessel." (1 page(s), 2/6/1997)