Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Information Notices - 1991

This page includes links to files in non-HTML format. See Plugins, Viewers, and Other Tools for more information.

Document Number Title Revision Publish Date Reviewed Date
IN-91-87 Hydrogen Embrittlement of Raychem Cryofit Couplings -- 12/27/1991 --
IN-91-86 New Reporting Requirements for Contamination Events at Medical Facilities (10 CFR 30.50) -- 12/27/1991 --
IN-91-85 Potential Failures of Thermostatic Control Valves for Diesel Generator Jacket Cooling Water 1 02/27/1997 --
-- 12/26/1991 --
IN-91-84 Problems with Criticality Alarm Components/Systems -- 12/26/1991 --
IN-91-83 Solenoid-Operated Valve Failures Resulted in Turbine Overspeed -- 12/20/1991 --
IN-91-82 Problems with Diaphragms in Safety-Related Tanks -- 12/18/1991 --
IN-91-81 Switchyard Problems that Contribute to Loss of Offsite Power S1 05/19/1994 --
-- 12/16/1991 --
IN-91-80 Failure of Anchor Head Threads on Post-Tensioning System During Surveillance Inspection -- 12/11/1991 --
IN-91-79 Deficiencies in the Procedures for Installing Thermo-Lag Fire Barrier Materials S1 08/04/1994 --
-- 12/06/1991 --
IN-91-78 Status Indication of Control Power for Circuit Breakers Used in Safety-Related Applications -- 11/28/1991 --
IN-91-77 Shift Staffing at Nuclear Power Plants -- 11/26/1991 --
IN-91-76 10 CFR Parts 21 and 50.55(e) Final Rules -- 11/26/1991 --
IN-91-75 Static Head Corrections Mistakenly Not Included in Pressure Transmitter Calibration Procedures -- 11/25/1991 --
IN-91-74 Changes in Pressurizer Safety Valve Setpoints Before Installation -- 11/25/1991 --
IN-91-73 Loss of Shutdown Cooling During Disassembly of High Pressure Safety Injection System Check Valve -- 11/21/1991 --
IN-91-72 Issuance of a Revision to the EPA Manual of Protective Action Guides and Protective Actions for Nuclear Incidents -- 11/19/1991 --
IN-91-71 Training and Supervision of Individuals Supervised by an Authorized User -- 11/12/1991 --
IN-91-70 Improper Installation of Instrumentation Modules -- 11/04/1991 --
IN-91-69 Errors in Main Steam Line Break Analyses for Determining Containment Parameters -- 11/01/1991 --
IN-91-68 Careful Planning Significantly Reduces the Potential Adverse Impacts of Loss of Offsite Power Events During Shutdown -- 10/28/1991 --
IN-91-67 Problems with the Reliable Detection of Intergranular Attack (IGA) of Steam Generator Tubing -- 10/21/1991 --
IN-91-66 (1) Erroneous Data in ... NUREG/CR-0095 and (2) Thermal Scattering Data Limitation ... KENO and SCALE Codes -- 10/18/1991 --
IN-91-65 Emergency Access to Low-Level Radioactive Waste Disposal Facilities -- 10/16/1991 --
IN-91-64 Site Area Emergency Resulting from a Loss of Non-Class 1E Uninterruptable Power Supplies S1 10/07/1992 --
-- 10/09/1991 --
IN-91-63 Natural Gas Hazards at Fort St. Vrain Nuclear Generating Station -- 10/03/1991 --
IN-91-62 Diesel Engine Damage Caused by Hydraulic Lockup Resulting from Fluid Leakage into Cylinders -- 09/30/1991 --
IN-91-61 Preliminary Results of Validation Testing of Motor-Operated Valve Diagnostic Equipment -- 09/30/1991 --
IN-91-60 False Alarms of Alarm Ratemeters Because of Radiofrequency Interference -- 09/24/1991 --
IN-91-59 Problems with Access Authorization Programs -- 09/23/1991 --
IN-91-58 Dependency of Offset Disc Butterfly Valve's Operation on Orientation with Respect to Flow -- 09/20/1991 --
IN-91-57 Operational Experience on Bus Transfers -- 09/19/1991 --
IN-91-56 Potential Radioactive Leakage to Tank Vented to Atmosphere -- 09/19/1991 --
IN-91-55 Failures Caused by an Improperly Adjusted Test Link in 4.16 KV General Electric Switchgear -- 09/16/1991 --
IN-91-54 Foreign Experience Regarding Boron Dilution -- 09/06/1991 --
IN-91-53 Failure of Remote Shutdown System Instrumentation Because of Incorrectly Installed Components -- 09/04/1991 --
IN-91-52 Nonconservative Errors in Overtemperature Delta-Temperature (OTdT) Setpoint Caused by Improper Gain Setting S1 07/16/1992 --
-- 08/29/1991 --
IN-91-51 Inadequate Fuse Control Programs -- 08/20/1991 --
IN-91-50 A Review of Water Hammer Events After 1985 S1 07/17/1997 --
-- 08/20/1991 --
IN-91-49 Enforcement of Safety Requirements for Radiographers -- 08/15/1991 --
IN-91-48 False Certificates of Conformance Provided by Westinghouse Electric Supply Company for Commercial-Grade Circuit Breakers -- 08/09/1991 --
IN-91-47 Failure of Thermo-Lag Fire Barrier Material to Pass Fire Endurance Test -- 08/06/1991 --
IN-91-46 Degradation of Emergency Diesel Generator Fuel Oil Delivery Systems -- 07/18/1991 --
IN-91-45 Possible Malfunction of Westinghouse ARD, BFD, and NBFD Relays, and A200 DC and DPC 250 Magnetic Contactors S1 07/29/1994 --
-- 07/05/1991 --
IN-91-44 Improper Control of Chemicals in Nuclear Fuel Fabrication -- 07/08/1991 --
IN-91-43 Recent Incidents Involving Rapid Increases in Primary-to-Secondary Leak Rate -- 07/05/1991 --
IN-91-42 Plant Outage Events Involving Poor Coordination Between Operations and Maintenance Personnel During Valve Testing and Manipulations -- 06/27/1991 --
IN-91-41 Potential Problems with the Use of Freeze Seals -- 06/27/1991 --
IN-91-40 Contamination of Nonradioactive System and Resulting Possibility for Unmonitored, Uncontrolled Release to Environment -- 06/19/1991 --
IN-91-39 Compliance with 10 CFR Part 21, "Reporting of Defects and Noncompliance" -- 06/17/1991 --
IN-91-38 Thermal Stratification in Feedwater System Piping -- 06/13/1991 --
IN-91-37 Compressed Gas Cylinder Missile Hazards -- 06/10/1991 --
IN-91-36 Nuclear Plant Staff Working Hours -- 06/10/1991 --
IN-91-35 Labeling Requirements for Transporting Multi-Hazard Radioactive Materials -- 06/07/1991 --
IN-91-34 Potential Problems in Identifying Causes of Emergency Diesel Generator Malfunctions -- 06/03/1991 --
IN-91-33 Reactor Safety Information for States During Exercises and Emergencies -- 05/31/1991 --
IN-91-32 Possible Flaws in Certain Piping Systems Fabricated by Associated Piping and Engineering -- 05/15/1991 --
IN-91-31 Nonconforming Magnaflux Magnetic Particle (14AM) Prepared Bath -- 05/09/1991 --
IN-91-30 Inadequate Calibration of TLDs Utilized to Monitor Extremity Dose at Uranium Processing and Fabrication Facilities -- 04/23/1991 --
IN-91-29 Deficiencies Identified During Electrical Distribution System Functional Inspections S3 11/22/1995 --
S2 12/22/1993 --
S1 09/14/1992 --
-- 04/15/1991 --
IN-91-28 Cracking in Feedwater System Piping -- 04/15/1991 --
IN-91-27 Incorrect Rotation of Positive Displacement Pump -- 04/10/1991 --
IN-91-26 Potential Nonconservative Errors ... Working Format Hansen-Roach Cross-Section Set Provided with the KENO and SCALE Codes -- 04/02/1991 --
IN-91-25 Commercial-Grade Structural Framing Components Supplied as Nuclear Safety-Related Equipment -- 04/01/1991 --
IN-91-24 Recent Operating Experience Involving Reactor Operation Without a Licensed RO or SRO Present in the Control Room -- 03/26/1991 --
IN-91-23 Accidental Radiation Overexposures to Personnel Due to Industrial Radiography Accessory Equipment Malfunctions -- 03/26/1991 --
IN-91-22 Four Plant Outage Events Involving Loss of AC Power or Coolant Spills -- 03/19/1991 --
IN-91-21 Inadequate Quality Assurance Program of Vendor Supplying Safety-Related Equipment S1 12/07/1993 --
-- 03/19/1991 --
IN-91-20 Electrical Wire Insulation Degradation Caused Failure in a Safety-Related Motor Control Center -- 03/19/1991 --
IN-91-19 Steam Generator Feedwater Distribution Piping Damage -- 03/12/1991 A 03/12/1991 B --
IN-91-18 High-Energy Piping Failures Caused by Wall Thinning S1 12/18/1991 --
-- 03/12/1991 --
IN-91-17 Fire Safety of Temporary Installations or Services -- 03/11/1991 --
IN-91-16 Unmonitored Release Pathways from Slightly Contaminated Recycle and Recirculation Water Systems at a Fuel Facility -- 03/06/1991 --
IN-91-15 Incorrect Configuration of Breaker Operating Springs in General Electric AK-Series Metal-Clad Circuit Breakers -- 03/06/1991 --
IN-91-14 Recent Safety-Related Incidents at Large Irradiators -- 03/05/1991 --
IN-91-13 Inadequate Testing of Emergency Diesel Generators (EDGs) -- 03/04/1991 --
IN-91-12 Potential Loss of Net Positive Suction Head (NPSH) of Standby Liquid Control System Pumps -- 02/15/1991 --
IN-91-11 Inadequate Physical Separation and Electrical Isolation of Non-Safety-Related Circuits From RPS Circuits -- 02/20/1991 --
IN-91-10 Summary of Semiannual Program Performance Reports on Fitness-for-Duty (FFD) in the Nuclear Industry -- 02/12/1991 --
IN-91-09 Counterfeiting of Crane Valves 1 09/25/2007 --
-- 02/05/1991 --
IN-91-08 Medical Examination for Licensed Operators -- 02/05/1991 --
IN-91-07 Maintenance Deficiency Associated with General Electric Horizontal Custom 8000 Induction Motors -- 02/04/1991 --
IN-91-06 Lock-Up of Emergency Diesel Generator and Load Sequencer Control Circuits Preventing Restart of Tripped EDG -- 01/31/1991 --
IN-91-05 Intergranular Stress Corrosion Cracking in Pressurized Water Reactor Safety Injection Accumulator Nozzles -- 01/30/1991 --
IN-91-04 Reactor Scram Following Control Rod Withdrawal Associated with Low Power Turbine Testing -- 01/28/1991 --
IN-91-03 Management of Wastes Contaminated with Radioactive Materials ("Red Bag" Waste and Ordinary Trash) -- 01/07/1991 --
IN-91-02 Brachytherapy Source Management -- 01/07/1991 --
IN-91-01 Supplier of Misrepresented Resistors -- 01/04/1991 --