Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Information Notices – 1980

This page includes links to files in non-HTML format. See Plugins, Viewers, and Other Tools for more information.

Document Number Title Revision Publish Date Reviewed Date
IN-80-45 Potential Failure of BWR Backup Manual Scram Capability -- 12/17/1980 --
IN-80-44 Actuation of ECCS in the Recirculation Mode while in Hot Shutdown -- 12/16/1980 --
IN-80-43 Failures of the Continuous Water Level Monitor for the Scram Discharge Volume at Dresden Unit No. 2 -- 12/05/1980 --
IN-80-42 Effect of Radiation on Hydraulic Snubber Fluid -- 11/24/1980 --
IN-80-41 Failure of Swing Check Valve in the Decay Heat Removal System at Davis-Besse Unit No. 1 -- 11/10/1980 --
IN-80-40 Excessive Nitrogen Supply Pressure Actuates Safety-Relief Valve Operation to Cause Reactor Depressurization -- 11/07/1980 --
IN-80-39 Malfunctions of Solenoid Valves Manufactured by Valcor Engineering Corporation -- 10/31/1980 --
IN-80-38 Cracking in Charging Pump Casing Cladding -- 10/31/1980 --
IN-80-37 Containment Cooler Leaks and Reactor Cavity Flooding at Indian Point Unit 2 -- 10/24/1980 --
IN-80-36 Failure of Steam Generator Support Bolting -- 10/10/1980 --
IN-80-35 Leaking and Dislodged Iodine-125 Implant Seeds S1 10/06/1982 --
-- 10/10/1980 --
IN-80-34 Boron Dilution of Reactor Coolant During Steam Generator Decontamination -- 09/26/1980 --
IN-80-33 Determination of Teletherapy Timer Accuracy -- 09/15/1980 --
IN-80-32 Clarification of Certain Requirements for Exclusive-Use Shipments of Radioactive Materials 1 02/12/1982 --
-- 08/29/1980 --
IN-80-31 Maloperation of Gould-Brown Boveri 480 Volt Type K-600S and K-DON 600S Circuit Breakers -- 08/27/1980 --
IN-80-30 Potential for Unacceptable Interaction between Control Rod Drive Scram...and Non-Essential Control Air at GE BWRs -- 08/19/1980 --
IN-80-29 Broken Studs on Terry Turbine Steam Inlet Flange S1 11/26/1980 --
-- 08/07/1980 --
IN-80-28 Prompt Reporting of Information in Accordance with 10 CFR 50.55(e) -- 06/11/1980 --
IN-80-27 Degradation of Reactor Coolant Pump Studs -- 06/11/1980 --
IN-80-26 Evaluation of Contractor QA Programs -- 06/10/1980 --
IN-80-25 Transportation of Pyrophoric Uranium -- 05/30/1980 --
IN-80-24 Low-Level Radioactive Waste Burial Criteria -- 05/30/1980 --
IN-80-23 Loss of Suction to Emergency Feedwater Pumps -- 05/29/1980 --
IN-80-22 Breakdowns in Contamination Control Programs -- 05/28/1980 --
IN-80-21 Anchorage and Support of Safety-Related Electrical Equipment -- 05/16/1980 --
IN-80-20 Loss of Decay Heat Removal Capability at Davis-Besse Unit 1 while in a Refueling Mode -- 05/08/1980 --
IN-80-19 NIOSH Recall of Recirculating-Mode (Closed-Circuit) Self-Contained Breathing Apparatus (Rebreathers) -- 05/06/1980 --
IN-80-18 Possible Weapons Smuggling Pouch -- 05/05/1980 --
IN-80-17 Potential Hazards Associated with Interchangeable Parts on Radiographic Equipment -- 05/05/1980 --
IN-80-16 Shaft Seal Packing Causes Binding in Main Steam Swing Disc Check and Isolation Valves -- 04/29/1980 --
IN-80-15 Axial (Longitudinal) Oriented Cracking in Piping -- 04/21/1980 --
IN-80-14 Safety Suggestions from Employees -- 04/02/1980 --
IN-80-13 General Electric Type SBM Control Switches - Defective Cam Followers -- 04/02/1980 --
IN-80-12 Instrument Failure Causes Opening of PORV and Block Valve -- 03/31/1980 --
IN-80-11 Generic Problems with ASCO Valves in Nuclear Applications Including Fire Protection Systems -- 03/14/1980 --
IN-80-10 Partial Loss of Non-Nuclear Instrument System Power Supply During Operation -- 03/07/1980 --
IN-80-09 Possible Occupational Health Hazard Associated with Closed Cooling Systems for Operating Power Plants -- 03/07/1980 --
IN-80-08 The States Company Sliding Link Electrical Terminal Block -- 03/07/1980 --
IN-80-07 Pump Shaft Fatigue Cracking -- 02/29/1980 --
IN-80-06 Notification of Significant Events S1 07/29/1980 --
-- 02/27/1980 --
IN-80-05 Chloride Contamination of Safety Related Piping and Components -- 02/08/1980 --
IN-80-04 BWR Fuel Exposure in Excess of Limits -- 02/04/1980 --
IN-80-03 Main Turbine Electro-Hydraulic Control System -- 01/31/1980 --
IN-80-02 8X8R Water Rod Lower End Plug Wear -- 01/25/1980 --
IN-80-01 Fuel Handling Events -- 01/04/1980 --