Operating Experience Smart Sample (OpESS) Program
The OpESS program is designed to provide NRC inspection staff a detailed synopsis of selected operating experience which the agency considers to have generic safety implication. The OpESS is designed as an additional tool to be used by agency staff in ROP baseline inspection preparation. The information and trends identified from OpESS inspections may provide further indication that a specific issue warrants additional agency action.
Operating Experience Smart Samples
Each OpESS has a unique and sequential identifier. The designator FY is "Fiscal Year," which will support tracking by the NRR Operating Experience Branch for determining OpESS utilization and effectiveness.
2000s: FY2023 | FY2020 | FY2019 | FY2018 | FY2012 | FY2009 | FY2008 | FY2007
OpESS |
Title |
Applicable to Inspection Procedure(s) |
Issue Date |
Reference Doc |
CN Number |
Word |
FY2007/01 |
PWR Containment Sump Recirculation Pipe Foreign Material Blockage |
IP 71111.15
IP 71111.17
IP 71111.20
IP 71111.21
IP 71152 |
11/20/06 |
R |
|
|
FY2007/02
Rev 3 |
Analysis of Flooding Vulnerabilities |
IP 71111.01
IP 71111.06
IP 71111.19 |
09/11/18 |
|
18-031 |
|
FY2007/03
Rev 3 |
Crane And Heavy Lift Inspection, Supplemental Guidance to IP 71111.20 and IP 71111.13 |
IP 71111.13
IP 71111.20 |
09/11/18 |
|
18-031 |
|
FY2007/04 |
BWR Core Power / Flow Map – supplemental inspection guidance for MC 2515D |
IP 71111.15
IP 71152 |
08/27/07 |
R |
|
|
FY2008/01 |
Negative Trend and Recurring Events Involving Emergency Diesel Generators |
IP 71111.04
IP 71111.15
IP 71111.19
IP 71111.22
IP 71152 |
11/29/07 |
R |
|
|
FY2009/01 |
Inspection of Electrical Connections for Motor Control Center, Circuit Breakers, and Interfaces |
IP 71111.12
IP 71111.19
IP 71111.21
IP 71111.22
IP 71152 |
10/29/08 |
R |
|
|
FY2009/02 |
Negative Trend and Recurring Events Involving Feedwater Systems |
IP 71111.04
IP 71111.15
IP 71111.19
IP 71111.22
IP 71152 |
12/23/08 |
R |
|
|
FY2012/02
Rev 1 |
Technical Specification Interpretation and Operability Determination |
IP 71111.15 |
05/17/12 |
R |
|
.docx |
FY2018/01 |
Evaluation of Licensee Actions Taken in Response to 10 CFR Part 21 Notification of the Potential Existence of Defects Related to Control Rod Drive Mechanism (CRDM) Thermal Sleeves |
IP 71152 |
11/19/18 |
R |
18-040 |
.docx |
FY2019/01 |
Commercial Grade Dedication, Procurement, and Design Control |
IP 71111.12
IP 71111.18
IP 71111.21M
IP 71111.21N |
07/30/19 |
R |
19-025 |
.docx |
FY2020/01 |
Flex Equipment Design Control, Maintenance, and Testing |
IP 71111.12
IP 71111.13
IP 71111.18
IP 71111.19
IP 71111.21M
IP 71111.22
IP 71152 |
10/21/20 |
|
20-053 |
|
FY2023/01 |
Digital Instrumentation and Controls |
IP 71111.18
IP 71111.21M
IP 71111.21N.03
IP 71111.21N.04
IP 71111.24
IP 71130.10
IP 71152 |
02/12/24 |
|
24-007 |
.docx |
FY2023/02 |
Probabilistic Risk Assessment Configuration Control |
IP 37060
IP 71111.06
IP 71111.13
IP 71111.18
IP 71111.21M
IP 71111.21N.05
IP 71111.24
IP 71151
IP 71152 |
01/09/24 |
|
24-002 |
.docx |