Log No |
Notifier |
Description |
Report Date |
Event No. / Accession No. |
2013-68-03 |
C&D Technologies, Inc. |
Final Report - Inability to Complete 10CFR Part 21 Evaluation Regarding Cracking in KCR-13 Standby Battery Jars |
07/18/2014 |
ML14212A401 |
2013-68-02 |
C&D Technologies, Inc. |
Updated Interim Report - Inability to Complete 10CFR Part 21 Evaluation Regarding Cracking in KCR-13 Standby Battery Jars |
05/09/2014 |
ML14134A122 |
2013-68-01 |
C&D Technologies, Inc. |
Updated Interim Report - Inability to Complete 10CFR Part 21 Evaluation Regarding Cracking in KCR-13 Standby Battery Jars |
02/24/2014 |
ML14063A434 |
2013-68-00 |
C&D Technologies, Inc. |
Interim Report - Inability to Complete 10CFR Part 21 Evaluation Regarding Cracking in KCR-13 Standby Battery Jars |
12/20/2013 |
ML13358A306 |
2013-67-00 |
Fisher Controls International LLC |
Fisher Type 377 Trip Valves Not Processed as Required |
12/19/2013 |
EN 49664 |
2013-66-01 |
TriVis Inc. |
Non-Destructive Weld Testing Failed to Meet Procedural Requirements |
01/29/2014 |
EN 49628 |
2013-66-00 |
TriVis Inc. |
Non-Destructive Weld Testing Failed to Meet Procedural Requirements |
12/13/2013 |
ML13358A046 |
2013-65-01 |
Flanders Filters |
Follow Up and Closure of Possible Deviation or Defect in Nuclear Qualified High Efficiency Particulate Air (HEPA) Filters |
01/07/2014 |
ML14010A086 |
2013-65-00 |
Flanders Filters |
Possible Deviation or Defect in Nuclear Qualified High Efficiency Particulate Air (HEPA) Filters |
12/09/2013 |
EN 49620 |
2013-64-00 |
GE Hitachi Nuclear Energy |
Failure of Relay Logic Card Modules in 2 Out of 4 Voters |
12/05/2013 |
ML13340A382 |
2013-63-00 |
Vogtle Units 3 & 4 |
10CFR50.55(e) Report - Deficiency Identified in Quality Assurance Program |
12/02/2013 |
EN 49595 |
2013-62-01 |
SCE&G (V. C. Summer 2 & 3) |
10 CFR 50.55(e) Report - Root Cause Analysis Identifies Significant Breakdowns in the CB&l-Lake Charles Quality Assurance Program |
12/19/2013 |
ML13358A317 |
2013-62-00 |
V. C. Summer Units 2 & 3 |
10CFR50.55(e) Report - Deficiency Identified in Quality Assurance Program |
11/26/2013 |
EN 49582 |
2013-61-00 |
Fisher Controls International |
Improper Dedication of Actuator Parts |
11/26/2013 |
EN 49581 |
2013-60-00 |
ABB, Inc. |
Deficiency Related to the Primary Close Latch in K-Line Circuit Breakers |
11/25/2013 |
ML13339A770 |
2013-59-00 |
Columbiana Hi Tech, LLC |
Identified Discrepancy with Individual NDT Level II Certification |
11/24/2013 |
EN 49569 |
2013-58-00 |
Engine Systems, Inc. |
Diode CR7 Wiring Reversed on Emergency Diesel Generator Automatic Voltage Regulator Panel |
11/13/2013 |
ML13324A490 |
2013-57-00 |
Flowserve |
Potential Defect in SMB Geared Limit Switch |
11/08/2013 |
ML13324A391 |
2013-56-01 |
CB&I Nuclear |
Closure of Interim Report Regarding Deviations of Supplied Materials for Wall Module Assembly |
12/18/2013 |
ML13361A096 |
2013-56-00 |
CB&I Nuclear |
Interim Report Regarding Deviations of Supplied Materials for Wall Module Assembly |
10/15/2013 |
ML13308A418 |
2013-55-02 |
CB&I (Chicago Bridge & Iron) |
Closure of Interim Report Regarding Commercial-Grade Dedication Nonconformance |
06/14/2014 |
ML14178A115 |
2013-55-01 |
CB&I (Chicago Bridge & Iron) |
Revised Interim Report Regarding Commercial-Grade Dedication Nonconformance |
10/18/2013 (Revised 10/25/2013) |
ML13304A512 |
2013-55-00 |
CB&I (Chicago Bridge & Iron) |
Interim Report Regarding Commercial-Grade Dedication Nonconformance |
10/18/2013 |
ML13296A027 |
2013-54-01 |
Catawba Nuclear Station |
Incomplete Brazing of Contacts on Diesel Generator Control Relay |
11/08/2013 |
ML13316B560 |
2013-54-00 |
Catawba Nuclear Station |
Incomplete Brazing of Contacts on Diesel Generator Control Relay |
10/10/2013 |
EN 49426 |
2013-53-00 |
Shaw AREVA MOX Services |
Nonconforming Welds that resulted in Cracks in HVAC Filter Housing Repair Welds |
09/30/2013 |
EN 49397 |
2013-52-01 |
Tennessee Valley Authority |
Closure of Interim Report: Browns Ferry 1, 2, and 3 - Emergency Diesel Generator Relay Contact Failed to Operate as Expected |
12/02/2013 |
ML13343A143 |
2013-52-00 |
Tennessee Valley Authority |
Browns Ferry 1, 2, and 3 - Emergency Diesel Generator Relay Contact Failed to Operate as Expected |
09/24/2013 |
ML13273A014 |
2013-51-00 |
ABB Inc. |
ABB Solid State Circuit Shield and Power Shield Relays Shipped with Incorrect Certificates of Conformance |
09/20/2013 |
EN 49372 |
2013-50-00 |
Rosemount Nuclear |
Rosemount Model 710DU Trip Units May Not Meet Established Post-Exposure Radiation Performance Criteria |
09/20/2013 |
EN 49370 |
2013-49-01 |
Tennessee Valley Authority |
Browns Ferry 3 - Closure of 10 CFR Part 21 Interim Report - General Electric (GE) Hitachi Nuclear Energy - SBM Type Manual Switch |
12/18/2013 |
ML13357A267 |
2013-49-00 |
Tennessee Valley Authority |
Browns Ferry 3 - General Electric Hitachi Nuclear Energy SBM Type Manual Switch Failed to Operate as Expected (Interim Report) |
09/12/2013 |
ML13260A077 |
2013-48-00 |
Emerson Process Management |
Improper Dedication of Fisher Controls Actuator Parts |
09/10/2013 |
ML13261A151 |
2013-47-01 |
South Carolina Electric and Gas |
Closure of 10CFR 50.55(e) Report - Incorrectly Labeled Containment Filtration System (VFS) Equipment for V. C. Summer Units 2 & 3 |
08/22/2013 |
ML13239A051 |
2013-47-00 |
South Carolina Electric and Gas |
Interim 10CFR 50.55(e) Report - Incorrectly Labeled Containment Filtration System (VFS) Equipment for V. C. Summer Units 2 & 3 |
06/17/2013 |
ML13170A468 |
2013-46-01 |
Westinghouse Electric Co. |
Closure of Interim Report - AP1000 Time Response for the Safety Analysis Cannot be Directly Measured |
11/22/2013 |
ML13331A082 |
2013-46-00 |
Westinghouse Electric Co. |
Interim Report - AP1000 Time Response for the Safety Analysis Cannot be Directly Measured |
08/23/2013 |
ML13239A055 |
2013-45-01 |
Baldor Electric Co. |
Motors May Have a Point of Entry for Foreign Material |
10/03/2013 |
ML13284A084 |
2013-45-00 |
Baldor Electric Co. |
Motors May Have a Point of Entry for Foreign Material |
08/23/2013 |
ML13246A087 |
2013-44-02 |
Mirion Technologies (Conax Nuclear) |
Report Closure - Unqualified Material Used in Electrical Penetration Assemblies |
02/05/2014 |
ML14042A202 |
2013-44-01 |
Mirion Technologies (Conax Nuclear) |
Interim Report Update - Unqualified Material Used in Electrical Penetration Assemblies |
09/23/2013 |
ML13277A010 |
2013-44-00 |
Mirion Technologies (Conax Nuclear) |
Interim Report - Unqualified Material Used in Electrical Penetration Assemblies |
08/23/2013 |
ML13246A084 |
2013-43-01 |
Watts Bar 1 |
Auxiliary Feedwater Level Control Valve Stem / Plug Assembly Out of Tolerance |
09/13/2013 |
ML13256A139 |
2013-43-00 |
Watts Bar 1 |
Auxiliary Feedwater Level Control Valve Stem / Plug Assembly Out of Tolerance |
08/16/2013 |
EN 49288 |
2013-42-01 |
AMEC Environment and Analysis, Inc. |
Final Report Regarding Laboratory Test Data on Safety Class C Concrete and Grout |
08/26/2013 |
EN 49234 |
2013-42-00 |
AMEC Environment and Infrastructure, Inc. |
Interim Report Regarding Laboratory Test Data on Safety Class C Concrete and Grout |
08/03/2013 |
ML13221A582 |
2013-41-00 |
Westinghouse Electric Co. |
Inconsistency Between the Intended Design Functionality of the SHIELD Passive Thermal Shutdown Seal (SDS) and that Observed During Post-Service Testing |
07/26/2013 |
ML13211A168 |
2013-40-01 |
ABB Inc. |
Deviation on HK Medium Voltage Circuit Breaker Close Latch Springs (Updated) |
04/08/2015 |
ML15103A244 |
2013-40-00 |
ABB Inc. |
Deviation on HK Medium Voltage Circuit Breaker Close Latch Springs |
07/31/2013 |
EN 49230 |
2013-39-01 |
Watts Bar 2 |
Construction Deficiency Final Report - Failure to Implement Plant Changes (a 10 CFR 50.55(e) Report)
|
08/21/2013 |
ML13240A006 |
2013-39-00 |
Watts Bar 2 |
Potential Programmatic Breakdown of the Quality Assurance Program (a 10 CFR 50.55(e) Report) |
07/22/2013 |
EN 49209 |
2013-38-01 |
National Technical Systems |
Updated Part 21 Report - Firmware Notice for Users of Yokogawa DX1000N and DX2000 Model Recorder |
01/20/2015 |
ML15022A650 |
2013-37-02 |
Ultra Electronics |
Final Report - Linear Indications / Cracks in Pressure Transmitter Flange Forging |
10/08/2013 |
ML13346A027 |
2013-37-01 |
Ultra Electronics |
Second Interim Report - Linear Indications / Cracks in Pressure Transmitter Flange Forging |
08/28/2013 |
ML13254A160 |
2013-37-00 |
Ultra Electronics |
Interim Report - Linear Indications / Cracks in Pressure Transmitter Flange Forging |
06/28/2013 |
ML13191A571 |
2013-36-01 |
Parker Hannifin Corporation |
Tubing Fittings Machined from 304L Stainless Steel instead of 316 Stainless Steel |
08/06/2013 |
ML13233A285 |
2013-36-00 |
Parker Hannifin Corporation |
Tubing Fittings Machined from 304L Stainless Steel instead of 316 Stainless Steel |
06/18/2013 |
EN 49132 |
2013-35-01 |
Westinghouse Electric Co. |
Final Report - AP 1000 Plant Pressurizer Support Columns And Embedment Load Inconsistency |
07/24/2013 |
ML13211A170 |
2013-35-00 |
Westinghouse Electric Co. |
Interim Report - AP 1000 Plant Pressurizer Support Columns and Embedment Load Inconsistency |
05/31/2013 |
ML13161A341 |
2013-34-01 |
Shaw AREVA MOX Services |
Closure of 60-Day Interim Report Notification: Weld Wire Samples for Commercial Grade Dedication |
07/19/2013 |
ML13200A344 |
2013-34-00 |
Shaw AREVA MOX Services |
60-Day Interim Report Notification: Weld Wire Samples for Commercial Grade Dedication |
05/28/2013 |
ML13149A290 |
2013-33-00 |
Crane Nuclear, Inc. |
Potential Valve Body Leakage - 2" Valve Assembly |
05/17/2013 |
ML13165A022 |
2013-32-00 |
Nine Mile Point Unit 2
|
Failure of High Pressure Core Spray System Pressure Pump due to Motor Winding Failure (a 10 CFR 50.73 Report) |
04/25/2013 |
ML13122A227 |
2013-31-00 |
Engine Systems, Inc. |
Fuel Injectors Failed Pressure Test (See related Part 21 report number 2013-16-00) |
05/03/2013 |
ML13127A014 |
2013-30-02 |
Curtiss Wright Electro-Mechanical Corp / Wollaston Alloys, Inc. |
Insufficient Process Control on Pump Impeller (Final Report from Wollaston Alloys, Inc.) |
06/17/2013 |
ML13205A059 |
2013-30-01 |
Curtiss Wright Electro-Mechanical Corp / Wollaston Alloys, Inc. |
Insufficient Process Control on Pump Impeller (Interim Report from Wollaston Alloys, Inc.) |
05/17/2013 |
EN 48998 |
2013-30-00 |
Curtiss-Wright Electro-Mechanical Corp. |
Insufficient Process Control on Pump Impeller |
05/03/2013 |
ML13127A013 |
2013-29-00 |
Curtiss-Wright Flow Control Co. |
Interim Report of a Potential Defect in a Relief Valve Bellows |
05/03/2013 |
ML13127A012 |
2013-28-00 |
Shaw AREVA MOX Services |
Defect identified in some Type 304L and 316L Stainless Steel pipe |
04/29/2013 |
ML13120A277 |
2013-27-02 |
ITT Engineered Valves, LLC |
Type M1 Diaphragms May Not Be Qualified for Specific Radiation Design Conditions |
06/25/2013 |
ML13177A413 |
2013-27-01 |
ITT Engineered Valves, LLC |
Type M1 Diaphragms May Not Be Qualified for Specific Radiation Design Conditions |
05/24/2013 |
ML13155A385 |
2013-27-00 |
ITT Engineered Valves, LLC |
Type M1 Diaphragms May Not Be Qualified for Specific Radiation Design Conditions |
04/26/2013 |
ML13120A112 |
2013-26-00 |
Engine Systems Inc. |
Refurbished Emergency Diesel Generator Cylinder Heads May Have Missing Valve Keeper Seals |
04/23/2013 |
ML13116A303 |
2013-25-00 |
Summer Units 2 & 3 |
Failure to Comply with Conditions of Construction Permit (a 50.55(e) Report) |
04/10/2013 |
EN 48910 |
2013-24-00 |
Vogtle Units 3 & 4 |
Failure to Comply with Conditions of Construction Permit (a 50.55(e) Report) |
04/10/2013 |
EN 48906 |
2013-23-00 |
Flowserve |
Limitorque Valves with Incorrect Motor Nameplates Installed |
04/05/2013 |
ML13099A093 |
2013-22-00 |
ABB Inc. |
Issue Concerning the Zero Point Acceleration (ZPA) Rating for 3 Phase Relay Type SSC-T |
04/01/2013 |
ML13093A155 |
2013-21-01 |
Watts Bar 2 |
Instrumentation Lines Not Inspected Completely for Proper Slope (an Interim 10 CFR 50.55(e) Report) |
04/29/2013 |
ML13121A427 |
2013-21-00 |
Watts Bar 2 |
Instrumentation Lines Not Inspected Completely for Proper Slope (a 10 CFR 50.55(e) Report) |
04/01/2013 |
EN 48871 |
2013-20-03 |
Integrated Resources Inc. |
Foxboro Power Supply Potential Failures due to Defective Tie Wraps and Holders (Final Recommendation) |
08/21/2013 |
EN 48863 |
2013-20-02 |
Integrated Resources Inc. |
Foxboro Power Supply Potential Failures due to Defective Tie Wraps and Holders (Final Report and Recommendation) |
07/05/2013 |
ML13238A253 |
2013-20-01 |
Integrated Resources Inc. |
Foxboro Power Supply Potential Failures due to Defective Tie Wraps and Holders (Update) |
04/01/2013 |
ML13093A153 |
2013-20-00 |
Integrated Resources Inc. |
Foxboro Power Supply Potential Failures due to Defective Tie Wraps and Holders |
03/28/2013 |
ML13091A387 |
2013-19-01 |
ATC Nuclear |
Retracted Part 21 Interim Report Involving Review of Seismic Methodology |
06/05/2013 |
ML13161A342 |
2013-19-00 |
ATC Nuclear |
Interim Part 21 Report Involving Review of Seismic Methodology |
03/28/2013 |
ML13091A388 |
2013-18-00 |
Electroswitch |
Series 24 CSR Relays with Potentially Oversized Drive Cam Component |
03/26/2013 |
ML13099A238 |
2013-17-00 |
Fairbanks Morse Engine |
Foreign Material Found Inside Emergency Diesel Generator Air Start Piping Assembly |
03/25/2013 |
ML13086A255 |
2013-16-01 |
Tennessee Valley Authority |
Browns Ferry Emergency Diesel Generator Replacement Fuel Injectors Failed a Pressure Test |
05/29/2013 |
ML13151A022 |
2013-16-00 |
Tennessee Valley Authority |
Browns Ferry Emergency Diesel Generator Replacement Fuel Injectors Failed a Pressure Test |
03/22/2013 |
ML13085A339 |
2013-15-01 |
Emerson Process Management |
Final Report on Incorrect Assembly Instructions for TopWorx GO Switches |
04/30/2013 |
ML13190A024 |
2013-15-00 |
Emerson Process Management |
Incorrect Assembly Instructions for TopWorx GO Switches |
03/22/2013 |
ML13085A340 |
2013-14-03 |
AAF International |
Final Report - Possible Deviation or Defect in Nuclear Qualified High Efficiency Particulate Air (HEPA) Filters. |
06/13/2013 |
ML13165A325 |
2013-14-02 |
AAF International |
Updated Interim Report - Possible Deviation or Defect in Nuclear Qualified High Efficiency Particulate Air (HEPA) Filters. |
05/02/2013 |
ML13126A075 |
2013-14-01 |
AAF International |
Possible Deviation or Defect in Nuclear Qualified High Efficiency Particulate Air (HEPA) Filters |
04/11/2013 |
ML13105A111 |
2013-14-00 |
AAF International |
Possible Deviation or Defect in Nuclear Qualified High Efficiency Particulate Air (HEPA) Filters |
03/18/2013 |
ML13079A320 |
2013-13-00 |
ASCO Valve, Inc. |
Direct Acting Three Way Solenoid Valve will not Shift when De-energized |
03/20/2013 |
ML13084A054 |
2013-12-01 |
Limerick |
Flowserve Model 28KXL Pump Impeller Defect |
04/15/2013 |
ML13106A062 |
2013-12-00 |
Limerick |
Flowserve Model 28KXL Pump Impeller Defect |
03/15/2013 |
ML13077A334 |
2013-11-00 |
Emerson Process Management |
Loose Fisher Controls Proximity Switch Target Magnets (a 10 CFR 50.55(e) Report) |
03/12/2013 |
ML13073A108 |
2013-10-02 |
Curtiss-Wright Flow Control |
Update to Part 21 Report on Scientech Dual Alarm Modules and Single Alarm Moduless |
03/20/2015 |
ML15089A437 |
2013-10-01 |
Curtiss-Wright Flow Control |
Update to Part 21 Report for Scientech Dual Alarm Modules and Single Alarm Modules |
03/25/2013 |
ML13095A011 |
2013-10-00 |
Curtiss-Wright Flow Control |
Scientech Dual Alarm Modules and Single Alarm Modules |
03/01/2013 |
ML13063A443 |
2013-09-01 |
Flowserve |
Wedge Pin Failure in Anchor Darling Motor Operated Double Disc Gate Valve (Update) |
07/11/2017 |
ML17194A825 |
2013-09-00 |
Flowserve |
Wedge Pin Failure in Anchor Darling Motor Operated Double Disc Gate Valve (See related Part 21 Report No. 2013-02-00) |
02/25/2013 |
ML13064A012 |
2013-08-03 |
Dresser-Rand |
Defective Raw Material Used to Manufacture Valve Stems for Terry Type Emergency Feedwater Pump Drive Turbines |
04/01/2014 |
ML14094A445 |
2013-08-02 |
Dresser-Rand |
Defective Raw Material Used to Manufacture Valve Stems for Terry Type Emergency Feedwater Pump Drive Turbines |
02/28/2014 |
ML14069A468 |
2013-08-01 |
Dresser-Rand |
Defective Raw Material Used to Manufacture Valve Stems for Terry Type Emergency Feedwater Pump Drive Turbines |
03/11/2013 |
ML13073A107 |
2013-08-00 |
Dresser-Rand |
Defective Raw Material Used to Manufacture Valve Stems for Terry Type Emergency Feedwater Pump Drive Turbines |
02/12/2013 |
ML13045A893 |
2013-07-00 |
Nucletron |
Nucletron mHDR Afterloader Software Communication Error |
11/21/2012 |
EN 48531 |
2013-06-05 |
CB&I Lake City (LC) |
Final Report: Indeterminate Status of Rebar Spices Used for Modules Being Supplied to AP1000 Projects Vogtle Unit 3 and V. C. Summer Unit 2 |
12/04/2013 |
ML13346A597 |
2013-06-04 |
CB&I Lake City (LC) |
Indeterminate Status of Rebar Spices Used for Modules Being Supplied to AP1000 Projects Vogtle Unit 3 and V. C. Summer Unit 2 |
11/24/2013 |
ML13337A164 |
2013-06-03 |
CB&I Lake Charles |
Indeterminate Status of Rebar Spices Used for Modules Being Supplied to AP 1000 Projects Vogtle Unit 3 and V. C. Summer Unit 2 |
09/24/2013 |
ML13269A017 |
2013-06-02 |
CB&I Lake Charles |
Indeterminate Status of Rebar Spices Used for Modules Being Supplied to AP 1000 Projects Vogtle Unit 3 and V. C. Summer Unit 2 |
07/24/2013 |
ML13210A039 |
2013-06-01 |
CB&I Lake Charles |
Indeterminate Status of Rebar Spices Used for Modules Being Supplied to AP 1000 Projects Vogtle Unit 3 and V. C. Summer Unit 2 |
05/29/2013 |
ML13151A038 |
2013-06-00 |
Shaw Modular Solutions |
Indeterminate Status of Rebar Splices Used for Modules Being Supplied to AP 1000 Projects Vogtle Unit 3 and V. C. Summer Unit 2 |
02/08/2013 |
ML13044A360 |
2013-05-01 |
Emerson Process Management |
TopWorx M8 Switches Built and Shipped with Adhesive that was Beyond its Expiration Date (Final Report) |
03/13/2013 |
ML13093A251 |
2013-05-00 |
Emerson Process Management |
TopWorx M8 Switches Built and Shipped with Adhesive that was Beyond its Expiration Date |
02/11/2013 |
ML13044A074 |
2013-04-00 |
Emerson Process Management |
Notification of Potential Part 21 Report Involving Fisher Type 546 and 546NS Transducers |
01/11/2013 |
ML13015A306 |
2013-03-01 |
MPR Associates, Inc. |
Part 21 Report on a Replacement Basler EDG Excitation System Failure |
03/29/2013 |
ML13092A118 |
2013-03-00 |
MPR Associates, Inc. |
Interim Report on a Replacement Basler EDG Excitation System Failure |
01/09/2013 |
ML13010A518 |
2013-02-00 |
Browns Ferry Unit 1 |
Anti-Rotation Pin Failure in 10-inch Anchor Darling (Flowserve) Double Disc Gate Valve |
01/04/2013 |
ML13008A321 |
2013-01-03 |
Watts Bar Unit 2 |
10 CFR 50.55(e) Final Report – Commercial Grade Dedication Program Degraded |
07/18/2013 |
ML13204A381 |
2013-01-02 |
Watts Bar Unit 2 |
10 CFR 50.55(e) Second Interim Report – Commercial Grade Dedication Program Degraded |
05/06/2013 |
ML13129A176 |
2013-01-01 |
Watts Bar Unit 2 |
10 CFR 50.55(e) Report Update - Commercial Grade Dedication Program Degraded |
01/31/2013 |
ML13037A455 |
2013-01-00 |
Watts Bar Unit 2 |
10 CFR 50.55(e) Report - Commercial Grade Dedication Program Degraded |
01/03/2013 |
EN 48646 |