Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Part 21 Reports - 2010

This page includes links to files in non-HTML format. See Plugins, Viewers, and Other Tools for more information.

Log No Notifier Description Report Date Event No. / Accession No.
2010-44-00 H.B. Robinson, Unit 2 Manual Reactor Trip Due to Failure of 'A' Steam Generator Level Module (a 10 CFR 50.73 Report) 01/05/2010 ML100110218
2010-43-00 Three Mile Island Nuclear Station, Unit 1 Multiple Main Steam Safety Valve Test Failures (a 10 CFR 50.73 Report) 10/07/2010 ML102860132
2010-42-00 Dresden Nuclear Power Station, Units 2 and 3 Reactor Protection System Nonconformance to a Design Standard (a 10 CFR 50.73 Report) 01/22/2010 ML100330292
2010-41-00 Phi-Delta, Inc. Error in PD STRUDL Software (Pipe Stress Module) 12/07/2010 ML110060129
2010-40-00 Hirschfeld Industries Structural Steel Beam Faults 12/14/2010 ML103500404
2010-39-00 Ultra Electronics Functional issue with Weed Instrument N7000 Series RTD Temperature Transmitters 12/07/2010 ML103420505
2010-38-00 Rosemount Nuclear Anomaly Discovered on certain Rosemount Model 1152 Differential Pressure Transmitters with Output Code "L" 10-50 mA Electronics 12/02/2010 ML103400155
2010-37-00 GE-Hitachi Nuclear Energy Reverse Polarity on HPCI Turbine EG-R Hydraulic Actuators 11/18/2010 ML103230317
2010-36-00 Curtiss Wright Flow Control Company / QualTech NP UPS Motherboard Failed Pre-Service Inspection 11/08/2010 ML103130423
2010-35-00 VELAN Inc. Defective Limitorque Type SMB-00 and Type SMB-2-06 Limit Switches 11/08/2010 ML103160299
2010-34-01 Control Components Inc. Susquehanna identifies potentially susceptible Drag® valves previously reported by Control Components Inc. 03/08/2011 ML110770043
2010-34-00 Control Components Inc. Potential for the Disk Stack to separate within certain Drag® valves. 10/29/2010 ML103060102
2010-33-02 Oconee Nuclear Station Defect observed in Mackson Tube Steel that could be used in various Safety-Related Structural Applications 10/13/2011 ML11287A139
2010-33-01 Oconee Nuclear Station Defect observed in Mackson Tube Steel that could be used in various Safety Related Structural Applications 11/22/2010 ML103350168
2010-33-00 Oconee Nuclear Station Defect observed in Mackson Tube Steel that could be used in various Safety Related Structural Applications 10/29/2010 ML103060087
2010-32-02 GE-Hitachi Nuclear Energy Design Life of D and S Lattice Marathon Control Blades 02/15/2011 ML110460487
2010-32-01 GE-Hitachi Nuclear Energy Crack Indications in Marathon Control Rod Blades 12/01/2010 ML103360004
2010-32-00 GE-Hitachi Nuclear Energy Crack Indications in Marathon Control Rod Blades 10/20/2010 ML102930505
2010-31-01 ASCO Valve Inc. External Leakage in NP8320 Solenoid Valve 11/11/2010 ML103190730
2010-31-00 ASCO Valve Inc. External Leakage in NP8320 Solenoid Valve 10/18/2010 ML102940033
2010-30-00 ABB Inc. Failure of Certain Solid State Relays to Comply 09/30/2010 ML102770418
2010-29-00 Dresser Masoneilan Potential Issues with certain Model 77N-40 Air Regulators 09/29/2010 ML102770105
2010-28-00 H. B. Robinson, Unit 2 Emergency Diesel Generator Inoperable in Excess of Technical Specifications Completion Time due to Output Breaker Failure (a 10 CFR 50.73 Report) 06/01/2010 ML101590222
2010-27-01 GE-Hitachi Nuclear Energy U.S. ABWR Turbine Building Design Requirements 10/11/2010 ML102850242
2010-27-00 Fluor Enterprises, Inc. U.S. ABWR Design Certification - Design Input Requirements for Main Steam Line Seismic Analysis 08/30/2010 ML102530168
2010-26-00 Rotork Controls, Inc. Defective Sintered Gear used in NA1E type Valve Actuator optional "Add On Pack" Sub-assemblies. 09/08/2010 ML102530446
2010-25-06 GE-Hitachi Nuclear Energy Failure to Include Seismic Input in Channel-Control Blade Interference Customer Guidance 02/07/2012 ML12040A283
2010-25-05 GE-Hitachi Nuclear Energy Failure to Include Seismic Input in Channel-Control Blade Interference Customer Guidance 12/19/2011 ML113530512
2010-25-04 GE-Hitachi Nuclear Energy Failure to Include Seismic Input in Channel-Control Blade Interference Customer Guidance 09/26/2011 ML112700066
2010-25-03 GE-Hitachi Nuclear Energy Failure to Include Seismic Input in Channel-Control Blade Interference Customer Guidance 08/11/2011 ML112240142
2010-25-02 GE-Hitachi Nuclear Energy Failure to Include Seismic Input in Channel-Control Blade Interference Customer Guidance 12/15/2010 ML103500174
2010-25-01 GE-Hitachi Nuclear Energy Failure to Include Seismic Input in Channel-Control Blade Interference Customer Guidance 09/27/2010 ML102700614
2010-25-00 GE-Hitachi Nuclear Energy Failure to Include Seismic Input in Channel-Control Blade Interference Customer Guidance 09/02/2010 ML102460537
2010-24-01 Cooper Nuclear Station GE-Hitachi 4160 VAC Control and Transfer Breaker Switch Defect 09/02/2010 ML102510125
2010-24-00 Cooper Nuclear Station GE-Hitachi 4160 VAC Control and Transfer Breaker Switch Defect 08/10/2010 ML102280174
2010-23-00 Rosemount Nuclear Instruments, Inc. Reliability Concern Related to Certain Model 3051N Pressure Transmitters 07/12/2010 ML101940309
2010-22-00 Trentec Failure of Ronken Oil-Filled 70 Microfarad Capacitor (Date Code 06-06) 07/06/2010 ML101890066
2010-21-00 Tyco Electronics Notification of Limited E7000 Relay Recall 06/16/2010 ML101720486
2010-20-00 C&D Technologies, Inc. Post Corrosion on DCU Batteries 05/28/2010 ML101530108
2010-19-00 GE Hitachi Nuclear Energy Bent Fuel Spacer Flow Wing – GNF2 Fuel 05/14/2010 ML101370065
2010-18-01 Dresser-Rand Soldering Defect on a Digital Control System Output Filter Printed Circuit Board 06/04/2010 ML101600189
2010-18-00 Dresser-Rand Soldering Defect on a Digital Control System Output Filter Printed Circuit Board 05/11/2010 ML101380397
2010-17-01 Oconee Nuclear Station Failed Backseat Gasket on 1-inch Flowserve Socket Welded Globe Valve with a Threaded Backseat 12/13/2010 ML103510024
2010-17-00 Oconee Nuclear Station Failed Backseat Gasket on 1-inch Flowserve Socket Welded Globe Valve with a Threaded Backseat 04/21/2010 ML101160034
2010-16-01 Engine Systems, Inc. EMD Diesel Jacket Water Pump with Incorrect Impeller Orientation 04/01/2011 ML110970152
2010-16-00 Engine Systems, Inc. EMD Diesel Jacket Water Pump with Incorrect Impeller Orientation 04/26/2010 ML101180062
2010-15-01 Waterford Unit 3 High Failure Rate of Normally Energized Tyco Electro-Pneumatic Time Delay Relays 04/29/2010 ML101230323
2010-15-00 Waterford Unit 3 High Failure Rate of Normally Energized Tyco Electro-Pneumatic Time Delay Relays 04/21/2010 EN 45862
2010-14-00 United Controls International Faulty Modulation Index Control (MIC) circuit boards for a Cyberex kVA Model AC Power Supply 04/14/2010 ML101100638
2010-13-01 Tyco Flow Control Failure of a Solenoid Valve Supplied with Crosby Dual Function Main Steam Safety Valves 04/29/2010 ML101270027
2010-13-00 Tyco Flow Control Failure of a Solenoid Valve Supplied with Crosby Dual Function Main Steam Safety Valves 04/02/2010 ML100960449
2010-12-00 Palisades Nuclear Plant Potential Loss of Safety Function Due to a Service Water Pump Shaft Coupling Failure 03/19/2010 ML100810408
2010-11-01 Crane Nuclear, Inc. Notification of a Potential Weld Defect 04/10/2013 ML13102A303
2010-11-00 Crane Nuclear, Inc. Notification of a Potential Weld Defect 03/25/2010 ML100920093
2010-10-01 GE-Hitachi Nuclear Energy Failure of HPCI Turbine Overspeed Reset Control Valve Diaphragm 07/01/2010 ML101820160
2010-10-00 GE-Hitachi Nuclear Energy Interim Report: Failure of HPCI Turbine Overspeed Reset Control Valve Diaphragm 03/22/2010 ML100820059
2010-09-00 Westinghouse Electric Co. Failure of Cutler-Hammer Type ARD 660UR DC Relays to Release When De-Energized 03/19/2010 ML100820434
2010-08-00 Oyster Creek Failure of Tyco/Agastat EGPI004 Relay due to Manufacturing Defect 02/08/2010 ML100541598
2010-07-00 United Controls International Faulty Logic Board for Cyberex 20 KVA Inverter Model AC 02/24/2010 ML100610675
2010-06-01 Oconee Nuclear Station Defect Associated with Welded Stud Attachment to Concrete Embed Plates 03/24/2010 ML100880321
2010-06-00 Oconee Nuclear Station Defect Associated with Welded Stud Attachment to Concrete Embed Plates 02/24/2010 ML100610346
2010-05-01 Westinghouse Electric Company Closure of Interim Report Concerning an Issue in Sump Blockage Generic Tests 03/30/2010 ML100900472
2010-05-00 Westinghouse Electric Company Interim Report Concerning an Issue in Sump Blockage Generic Tests 02/12/2010 ML100480138
2010-04-00 United Controls International Installation of Incorrect Transformer on a Control Board for a Battery Charger 02/12/2010 ML100512907
2010-03-01 ABB Inc. Potential Failure of a Breaker Closing Coil Component to Comply with Design Specifications 03/08/2010 ML101060223
2010-03-00 ABB Inc. Potential Failure of a Breaker Closing Coil Component to Comply with Design Specifications 02/08/2010 ML100512906
2010-02-01 Sulzer Pumps Defect in Pump Shaft Journal Coating 02/01/2010 ML100470023
2010-02-00 Sulzer Pumps Defect in Pump Shaft Journal Coating 01/27/2010 ML100290368
2010-01-01 ABB Inc. Circuit Breaker Charging Motor Crank Does Not Meet Hardness Specifications 02/05/2010 ML100512905
2010-01-00 ABB Circuit Breaker Charging Motor Crank Does Not Meet Hardness Specifications 01/23/2010 ML100251422