Part 21 Reports - 2003
This page includes links to files in non-HTML format. See Plugins, Viewers, and Other Tools for more information.
| Log No | Notifier | Description | Report Date | Access No |
|---|---|---|---|---|
| 2003-001-00 | Ingersoll-Rand | Unstaked Capscrews Renders Residual Heat Removal Pump Inoperable | 12/20/2002 | ml023650495 |
| 2003-001-01 | Vogtle | Inadequately Staked Capscrews Render RHR Pumps Inoperable - UPDATE | 12/05/2003 | ml033430282 |
| 2003-002-00 | Whiting Corp | One or possibly two internal support bolts in #25 Hoist Unit (Gear Case) may be significantly over-stressed | 01/29/2003 | ml030430027 |
| 2003-002-01 | Whiting Corp | Follow-up notice related to the previously reported Part 21 from Whiting Corp. dated 1/29/2003 | 02/12/2003 | ml030520271 |
| 2003-003-00 | Rockbestos-Suprenant Corp. | Firewall III cables may include an alternate resin which was not part of the baseline qualification testing | 01/14/2003 | ml030240121 |
| 2003-003-01 | Rockbestos-Suprenant Corp. | Follow-up-Firewall III cables may include an alternate resin which was not part of the baseline qualification testing | 02/13/2003 | ml030570149 |
| 2003-004-00 | Scientech | Square Root Function (CMM900) modules have been found to be defective | 01/14/2003 | Event Notification 39516 |
| 2003-004-01 | Scientech | Follow-up - Square Root Function (CMM900) modules have been found to be defective | 02/15/2003 | ml030520269 |
| 2003-004-02 | Scientek | Update - Square Root Function (CMM900) modules have been found to be defective | 02/05/2009 | ML090400748 |
| 2003-005-00 | Nine Mile Point | LER - Main steam isolation valve (MSIV) disc separated from its stem allowing the disc/piston assembly to drop into the valve seat | 01/07/2003 | ml030230404 |
| 2003-006-00 | Boeing | Errors associated with the computer codes "ANSYS" and "GTSTRUDL" | 01/20/2003 | ml030280443 |
| 2003-006-01 | Boeing Co. | Transmittal of Error Notices Received from Former Software Suppliers (Followup) | 12/18/2003 | ml033650352 |
| 2003-007-00 | Carboline Company | Deficiencies in coating film affecting its a application and aesthetic properties | 02/17/2003 | ml030550248 |
| 2003-008-00 | Holtec International | Potential defect in Aalborg model GFM671S mass flow rate meters | 03/06/2003 | ml030690012 |
| 2003-009-00 | Electrak Corp | Errors associated with fire hazards module within the TRAK2000 Cable Management and Appendix R Analysis System software | 03/07/2003 | ml030940364 |
| 2003-010-00 | Westinghouse Electric Co | Failed circuit breakers manufactured by ABB and retrofitted by Westinghouse use for Class 1E applications | 03/14/2003 | ml030790432 |
| 2003-010-01 | ABB, Inc. | Clarification Regarding the Failure of Circuit Breakers Shipped to Calvert Cliffs Plant | 12/26/2003 | ml033650312 |
| 2003-011-00 | Engine Systems Inc. | Stability and amplifier gain potentiometers swap on EGM control | 04/21/2003 | ml031200116 |
| 2003-012-00 | General Electric | GE Nuclear reports a new phenomenon that causes fuel channel bowing | 03/03/2003 | ml031420086 |
| 2003-012-01 | General Electric | Interim surveillance program for fuel channel bowing | 04/28/2003 | ml031420346 |
| 2003-012-02 | General Electric | Interim surveillance program for fuel channel bowing - Plant exclusion | 04/30/2003 | ml031420339 |
| 2003-012-03 | General Electric | GE Nuclear reports a new phenomenon that causes fuel channel bowing - Update | 06/06/2003 | ml031700267 |
| 2003-012-04 | General Electric | Report involving impact of Fuels Channel Bowing - Follow-up | 07/18/2003 | Event Notification 40005 |
| 2003-012-05 | General Electric | Final Report involving impact of Fuels Channel Bowing | 11/18/2003 | ml033280519 |
| 2003-013-00 | ABB Inc. | Concerns relating to the Class 1E Type TD-5 Relay | 02/24/2003 | ml031830141 |
| 2003-013-01 | ABB Inc. | Concerns relating to the Class 1E Type TD-5 Relay - Evaluation/Followup | 05/16/2003 | ml031470289 |
| 2003-014-00 | ABB Inc. | Concerns relating to the Class 1E Type KLF/KLF-1 Relay | 02/24/2003 | ml031830141 |
| 2003-014-01 | ABB Inc. | Concerns relating to the Class 1E Type KLF/KLF-1 Relay - Evaluation/Followup | 05/16/2003 | ml031470313 |
| 2003-015-00 | ABB Inc. | Concerns relating to the Class 1E Type COV-8/COV-9 Relay | 02/24/2003 | ml031830141 |
| 2003-015-01 | ABB Inc. | Concerns relating to the Class 1E Type COV-8/COV-9 Relay - Evaluation/Followup | 05/16/2003 | ml031470326 |
| 2003-017-00 | Engine Systems Inc. | Condition reported with an EMD electric start motor at Oyster Creek Generating Station | 06/11/2003 | ml031690386 |
| 2003-018-00 | VC Summer | Failure of a Safety-Related K-Line circuit breaker | 06/11/2003 | ml031690399 |
| 2003-018-01 | VC Summer | Failure of a Safety-Related K-Line circuit breaker | 02/23/2004 | ml040570633 |
| 2003-019-00 | Thermo Electron Corp | Potential defect in Thermo Westronics Model 2100C Series Recorders | 07/21/2003 | ml032170035 |
| 2003-020-00 | Westinghouse Electric Co | Potential defect in Cuttler Hammer circuit breakers | 09/04/2003 | ml032510902 |
| 2003-021-00 | Ederer, LLC | Potential Safety hazard involving crane emergency drum brake | 09/10/2003 | ml032580450 |
| 2003-022-00 | Florida Power & Light | Issue at Seabrook regarding Spent Fuel Test Coupons | 09/15/2003 | ml032650709 |
| 2003-022-01 | Florida Power & Light | Issue at Seabrook regarding Spent Fuel Test Coupons - Followup | 10/06/2003 | ml032880525 |
| 2003-023-00 | Framatome | Report regarding failure of the Eaton Cutler - Hammer Freedom Series Heater Packs | 09/30/2003 | ml032750756 |
| 2003-024-00 | Framatome | Report regarding Eaton Cutler-Hammer Type W Vintage Unit plug in stabs | 10/09/2003 | ml032870422 |
| 2003-025-00 | General Electric | Stability Option III Period Based Detection Algorithm Allowable Settings | 10/04/2003 | ml032870429 |
| 2003-026-00 | Callaway | GE Magne-Blast Breaker Tube and Piston Assemblies | 10/29/2003 | Event Notification 40283 |
| 2003-027-00 | Callaway | GE Low Voltage Circuit Breakers | 11/20/2003 | Event Notification 40344 |
| 2003-028-00 | VC Summer | Defective Master Relay in solid state protective system | 12/01/2003 |
Event Notification 40364 |
| 2003-029-00 | Automatic Valve | Failure of Solenoid Operated Valve to Close at Elevated Air Pressure | 12/16/2003 | Event Notification 40393 |
| 2003-030-00 | Cardinal Health Radiation Management Services | Potential Failure of Model 877-1 High Range Containment Monitor Detectors | 11/18/2003 | ml033240134 |
| 2003-031-00 | Framatome ANP | Fuel Assembly Bow Analysis | 12/09/2003 | ml033460173 |
| 2003-032-00 | Operation Technology, Inc. | Deviation Assessment ETAP Library Data | 12/09/2003 10/31/2003 08/14/2003 06/23/2003 04/08/2003 03/07/2003 |
ml033490454 ml033080019 ml032310169 ml031750083 ml031040224 ml030660635 |
| 2003-033-00 | Cardinal Health Radiation Management Services | Potential Failure of Model 977-201 and 977-210 Wide Range Ion Chamber Area Monitors | 12/23/2003 | ml033630565 |
| 2003-033-01 | Cardinal Health Radiation Management Services | Potential Failure of Model 977-201 and 977-210 Wide Range Ion Chamber Area Monitors - Updated | 01/28/2004 | ml040300254 |