eNRC F OHM 366U.S. NUCLEAR REGULATORY COMMISSION'(7 77).,ILICENSEE EVENT REPORT|-.CONTROL BLOCK: | | | | | ||h(PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION)1 6l o l i l l o i n I n i n is l i l@l0 10 l- 10 10 10 is 10 l- le 10 l@l4 11 11 11 11 l@lIl@7 8 9 LICENSEE CODE14 15 L...
Allen, WilliamFrom:Sent:To:Subject:Attachments:Ireland, JoAnnFriday, July 20, 2012 3:46 PMAllen, WilliamCroft 3979A containment RAIs and draft SERCroft 3979A containment RAIs.docx; Croft 3979A containment draft SER.docxChris,Attached are my Croft 3979A containment RAIs and dra...
Progress Energy FEB 1 9 2003 United States Nuclear Regulatory Commission SERIAL: HNP-03-015 ATTENTION: Document Contro 'Desk Washington, DC 20555 SHEARON HARRIS NUCLEAR POWER PLANT DOCKET NO. 50-400/LICENSE NO. NPF-63 TECHNICAL SPECIFICATION BASES CHANGE - CONTAINMENT ISOLATIO...
.O O---Vepcos/ y>wac.ima e.scrme.o,o#cosacoser. ,Surry Power Station ,P.O. nox 315Surry Virginia 23883necember 31, 1974-,.Director of Regulatory Operations230 PeachtreeSuite 818Atlanta, Georgia 30303This is to inform you by telecopy within twenty-four (24) hours ofan Abnorma! ...
+.CONTAINMENT SYSTEMS'CONTAINMENT VENTILATION SYSTEMLIMITING CONDITION FOR OPERATION3.6.1.7 The 48-inch containment purge supply and exhaust isolation-valves (CBV-HV-3198A, 3198D, 3196, 3197) shall be decctivated andsecured in their closed position. The 8-inch containment vent...
-.iNUREG/CR-5957IS-5083 !!l|'System 80Containment --Struc~ ural Design Review,!!:,sI|Prepared byL Greimann, F. Fanous, R. Challa, D. IlluhmAmes Laboratory|Iowa State UniversityPrepared for'U.S. Nuclear Regulatory Commission,Irt9306010330 930531PDR ADOCK 05200002A PDR':V:p%.fIi...
REQUEST FOR ADDITIONAL INFORMATION NO. 126-1558 REVISION 0 112/16/2008 US-APWR Design Certification Mitsubishi Heavy Industries Docket No. 52-021 SRP Section: 06.02.01 - Containment Functional Design Application Section: 6.2.1 QUESTIONS for Containment and Ventilation ...
_- _ _ _.t.-.|. . ,|,.,i,-|!tExhibit B {::-,Monticello Nuclear Generating Plantji!'Revision 1 to License Amendment Reauest dated June 8.1994:tProposed Changes Marked Up on Existing ;Technical Specification Pages'!Exhibit B consists of the existing Technical Specification pages...
September 23, 2016 RA-16-082 U.S. Nuclear Regulatory Commission One White Flint North · Attn: Document Control Desk or 0-881 11555 Rockville Pike Rockville, MD 20852 Technical Specification 4.5.G Oyster Creek Nuclear Generating Station Renewed Facility Operating License No. DP...
T-c ,:|a*', .D.'Containment Integrity *Containment integrity is defined to exist when:1) Penetrations required to be isolated during accident conditions are either:Capable of being closed by an operable automatic containment isolation valve,a.1OR!lb.Closed by an operable conta...
Attachment A Technical Specification Page RevisionsConsolidated Edison Company of New York, Inc. Indian Point Unit No. 2 Docket No. 50-247 8766- -20275e706'-7 --June, 1987 ADP 0500247 PDRe. One channel of heat tracing may be out of service for 48 hours. f. One refueling wate...
April 25, 2000Mr.CharlesM.DuggerVice President OperationsEntergy Operations, Inc.17265 River RoadKillona, LA 70066SUBJECT: WATERFORD STEAM ELECTRIC STATION, UNIT 3 - REQUEST FORINFORMATION RELATED TO TECHNICAL SPECIFICATION CHANGEREGARDING CONTAINMENT BUILDING PENETRATIONS DUR...
Masters, Anthony~42fI) ~From:Sent:To:Cc:Subject:Attachments:Categories:Lake, LouisTuesday, November 24, 2009 9:23 AMCarrion, Robert; Thomas, George; Masters, Anthony; Dan nausFranke, MarkFW: 2009 Nov 23 - Containment Unfolded GraphicsIR Mosaic.pptx2009 Nov 23 - Containment Unf...
Emergency Preparedness Program Frequently Asked Question (EPFAQ) EPFAQ Number: 2018-03 Originator: David Young Organization: NEI Relevant Guidance: This question concerns NEI 99-01, Development of Emergency Action Levels for Non-Passive Reactors, Revision 6. Applicable S...
.Ii!O !:ii|i| Nebraska Public Power District.!::; Cooper Nuclear Station..OPLANTUNIQUE ANALYSIS REPORTMark I Containment Program,i,!i41Revision 0OA p ril,19 8 2'8 2 0.5 0 4 0 3M. - . - - - - _ . _ - _ _ - _ . - _ _ _ - - _ - - .ABSTRACT'k Nebraska Public Power District(NPPD)ha...
- 4 -(2) Technical Specifications and Environmental Plan*The Technical Specifications contained in Appendices A and B,as revised through Amendment No. 260, are hereby incorporatedin the license. The licensee shall operate the facility inaccordance with the Technical Specificat...
March 9, 2000vf ruŽ #S 1T2 , (I'? Mr. Harold B. Ray Executive Vice President Southern California Edison Company San Onofre Nuclear Generating Station P.O. Box 128 San Clemente, CA 92674-0128SUBJECT: SAN ONOFRE NUCLEAR GENERATING STATION, UNITS 2 AND 3 ISSUANCE OF AMENDMENTS...
consumers Power company General Offices: 212 West Michigan Avenue, Jackson, Michigan 49201 • (517) 788-0550 January 8, 1981 Mr James G Keppler Office of Inspection and Enforcemept Region III U S Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137 DOCKET 50-25...
_TENNESSEE VALLEY AUTHORITY, -T 'CH ATTANOOGA, TENNESSEE 374ol400 Chestnut Street Tower II S)6oh~April 29, 1981l4hMr. Harold R. Denton, Directorh*,Office of Nuclear Reactor Regulation' 1 A. / - s'U.S. Nuclear Regulatory Commission% 3 gb'Y#NWashington, DC 20555Dear Mr. Denton:I...
-. . - .., , .,hrM North'suonoox srnnon umr 1i=imiiE== Aflanfic;Energy Service Corporationim;,Facility Operating' License NPF-86 ' Docket No. 50-443|License Amendment Request No'L93-05 .Containment l_ solation Design fore iPurge Supply and Exhaust _ Penetration - ,i.iiThis L...
. _ __NUREG/CR-2836LMSC D812950iVol.1, Part 2||Buckling of Steel Containment Shells.Task 1b: Buckling of Washington Public Power Supply Systems'Plant No. 2 Containment VesselPrepared by E. Meller, D. BushnellLockheed Palo Alto Research LaboratoryPrepared forU.S. Nuclear Regula...
(WOG-124, Rev. 1)TSTFr401(W G14 Rev 1)_TF.Industry/TSTF Standard Technical Specification Change TravelerRevise Incorrect Bases for Containment Air TemperatureClassification: 2) Bases Only ChangePriority: 4)Edit/BasesNUREGsAffected: E 1430 E 1431 V 1432 i 1433 W 1434Description...
DIABLO CANYON SITEUNIT NO. 2REPORT OF CONTAINMENT STRUCTURESTRUCTURAL INTEGRITY TESTPACIFIC GAS & ELECTRIC CO.77 BEALE STREETSAN FRANCISCO, CALIFORNIA 94106Bi073000i5Bi0722'DRADOCK05000275APDRCONTENTS~PaeGeneral SummaryDescription of the Containment StructurePredicted Response...
-- - - . . - _. ---NUREG-1037ContainmentPerformanceWorkingGroup ReportDraft Report for Comment' U.S. Nuclear RegulatoryCommissionOffics of Nuclear Reactor Regulationp*"%q'-.....|tg 61 g g 8505311037 R PDR.>,._b%%3NOTICEAvailability of Reference Materials Cited in NRC Publicati...
WASTE CONTAINMENT: STRATEGIES & PERFORMANCE C.H. Bensnn University of Wisconsin-Madison, Madison, Wisconsin USA ABSTRACT This paper reviews strategies for lining and covering waste containment systems, as well as systems used to remove leachate. Emphasis is placed on factors i...