INFORMATION REPORT
November 5, 2009 SECY-09-0164
For: The Commissioners
From: Nader L. Mamish
Assistant for Operations
Office of the Executive Director for Operations
Subject: WEEKLY INFORMATION REPORT - WEEK ENDING
OCTOBER 30, 2009
Conte...
INFORMATION REPORT
August 12, 2008 SECY-08-0116
For: The Commissioners
From: Vonna L. Ordaz, Assistant for Operations, Office of the EDO
Subject: WEEKLY INFORMATION REPORT - WEEK ENDING
AUGUST 1, 2008
Contents Enclosure
Nuclear Reactor Regulat...
March 4, 2003
Mr. Fred Dacimo
Vice President - Indian Point Nuclear Generating Station
Entergy Nuclear Operations, Inc.
295 Broadway, Suite 1
Post Office Box 249
Buchanan, NY 10511-0249
SUBJECT: ANNUAL ASSESSMENT LETTER - INDIAN POINT NUCLEAR
GENERATING UNIT 2 (REPORT 50-2...
Farley 1
Initiating Events
Significance: N/A Jun 30, 2001
Identified By: NRC
Item Type: FIN Finding
No Performance Monitoring criteria established for Maintenance Rule function C22A, Control of Steam Generator Level
No Color. The inspectors identified that the license...
McGuire 1
Initiating Events
Significance: Mar 23, 2002
Identified By: Self Disclosing
Item Type: NCV NonCited Violation
Failure to Follow Power Ranger Test Procedure
Licensee Identified Violation of Technical Specification 5.4.1.a, which requires that written procedu...
Arkansas Nuclear 2
1Q/2008 Plant Inspection Findings
Initiating Events
Significance: Nov 09, 2007
Identified By: Self-Revealing
Item Type: NCV NonCited Violation
INADEQUATE MAINTENANCE PROCEDURE FOR MOTOR CONTROL CENTER BREAKERS
A self-revealing noncited violation o...
Arkansas Nuclear 1
2Q/2008 Plant Inspection Findings
Initiating Events
Significance: Dec 31, 2007
Identified By: NRC
Item Type: NCV NonCited Violation
Failure to Control Combustible Material Brought Into the Auxiliary Building
Green. The inspectors identified a Gree...
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
05/30/2003 - 06/02/2003
** EVENT NUMBERS **
39883 ...
U.S. Nuclear Regulatory CommissionOperations Center Event Reports For11/07/2013 - 11/08/2013 ** EVENT NUMBERS ** 494074948449485494884951149512495144951549516 !!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!! Power ReactorEvent Number: 49407 Facility:...
INFORMATION REPORT
July 11, 2008 SECY-08-0102
For: The Commissioners
From: Vonna L. Ordaz, Assistant for Operations, Office of the EDO
Subject: WEEKLY INFORMATION REPORT - WEEK ENDING
JULY 4, 2008
Contents Enclosure
Nuclear Reactor Regulation ...
Oyster Creek
3Q/2003 Plant Inspection Findings
Initiating Events
Significance: Dec 28, 2002
Identified By: Self Disclosing
Item Type: FIN Finding
Inadequate procedures and personnel error cause (NOUE) offgas ignition
An inadequate maintenance procedure resulted in t...
Farley 1
Initiating Events
Significance: N/A Nov 17, 2000
Identified By: NRC
Item Type: FIN Finding
WHITE PERFORMANCE INDICATOR (PI) FOR UNPLANNED POWER REDUCTIONS
SUPPLEMENTAL INSPECTION: this inspection, performed in accordance with NRC Inspection Procedure 95001, w...
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
06/11/2003 - 06/12/2003
** EVENT NUMBERS **
39917 ...
Turkey Point 4
1Q/2010 Plant Inspection Findings
Initiating Events
Significance: Jun 30, 2009
Identified By: Self-Revealing
Item Type: NCV NonCited Violation
Failure to Implement Procedures for Conducting A Valve Alignment Causes Spill of Reactor Coolant And
Contami...
INFORMATION REPORT
December 31, 2007 SECY-07-0223
For: The Commissioners
From: Vonna L. Ordaz, Assistant for Operations, Office of the EDO
Subject: WEEKLY INFORMATION REPORT - WEEK ENDING
DECEMBER 21, 2007
Contents Enclosure
Nuclear Reactor Regu...
| January | February | March | Apil | May | June | July | August | September | October | November |This page includes links to files in non-HTML format. See Plugins, Viewers, and Other Tools for more information.DecemberPNO-III-03-04512/24/2003Southwest General Health Center/I...
U.S. Nuclear Regulatory CommissionOperations Center Event Reports For01/15/2015 - 01/16/2015 ** EVENT NUMBERS ** 5035150717507215072350724507375073950740Power ReactorEvent Number: 50351 Facility: HATCH Region: 2 State: GA Unit: [1] [ ] [ ] RX Type: [1] GE-4,[...
Arkansas Nuclear 1
3Q/2008 Plant Inspection Findings
Initiating Events
Significance: Jun 23, 2008
Identified By: NRC
Item Type: FIN Finding
Loss of 500 kV power line due to switchyard maintenance
The inspectors documented a self-revealing finding for emergent work p...
Supplemental (S) Questions and Answers Regarding
Implementation of the Order Imposing Fingerprinting and Criminal
History Check Requirements For Unescorted Access to Certain
Radioactive Material (EA-07-305)
Version: 12/10/10
Table of Contents
Questions ...
Farley 1
Initiating Events
Significance: N/A Nov 17, 2000
Identified By: NRC
Item Type: FIN Finding
WHITE PERFORMANCE INDICATOR (PI) FOR UNPLANNED POWER REDUCTIONS
SUPPLEMENTAL INSPECTION: this inspection, performed in accordance with NRC Inspection Procedure 95001, w...
INFORMATION REPORT
February 8, 2007 SECY-07-0029
For: The Commissioners
From: Michael R. Johnson, Assistant for Operations, Office of the EDO
Subject: WEEKLY INFORMATION REPORT - WEEK ENDING
FEBRUARY 2, 2007
Contents Enclosure
Nuclear Reactor Regulation A
New Reactors B...
U.S. Nuclear Regulatory CommissionOperations Center Event Reports For02/03/2012 - 02/06/2012 ** EVENT NUMBERS ** 4762747632476344763547636476374763847639Agreement StateEvent Number: 47627 Rep Org: CALIFORNIA RADIATION CONTROL PRGM Licensee: CONSTRUCTION TESTING & ENGINE...
June 30, 2006
MEMORANDUM TO: Luis A. Reyes
Executive Director for Operations
Karen D. Cyr
General Counsel
FROM: Annette L. Vietti-Cook, Secretary /RA/
SUBJECT: STAFF REQUIREMENTS - SECY-06-0126 - PROPOSED
RULEMAKING - POWER REACTOR SECURITY
REQUIREMENTS (RIN 3150-AG63)
...
Farley 2
Initiating Events
Significance: Aug 25, 2001
Identified By: NRC
Item Type: NCV NonCited Violation
Failure to Properly Establish the Initial Conditions for the Unit 2 Feedwater Level Control System Switches
The failure to properly establish the initial condit...
Fort Calhoun
4Q/2007 Plant Inspection Findings
Initiating Events
Significance: Sep 30, 2007
Identified By: NRC
Item Type: FIN Finding
Ineffective Corrective Actions for Hydrazine Spills
A Green self-revealing finding was identified for inadequate corrective actions,...