Location: Avila Beach, CA (12 miles WSW of San Luis Obispo, CA); Region IV; Type: Westinghouse Four-Loop; Licensed MWt: 3304
Location: Avila Beach, CA (12 miles WSW of San Luis Obispo, CA); Region IV; Type: Westinghouse Four-Loop; Licensed MWt: 3468
January 3, 2013 Mr. Edward D. Halpin Senior Vice President and Chief Nuclear Officer Pacific Gas and Electric Company Diablo Canyon Power Plant P.O. Box 56, Mail Code 104/6 Avila Beach, CA 93424 SUBJECT: DIABLO CANYON POWER PLANT, UNITS 1 AND 2 - NRC EXAMINATION REPORT 0...
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 November 15, 2019 MEMORANDUM TO: Bruce A. Watson, CHP, Chief Reactor Decommissioning Branch Division of Decommissioning, Uranium Recovery and Waste Programs Office of Nuclear Material Safety...
N~%fNRC FGRM 196U.S. NUCLEAR REGULATORV COMMISSIONNRC DISTRISUTION FOR PART 50 DOCKET MATERIALOOCKET NUMBERF LE NUMBEg-o~ COABETTER~ORIGINAIOCOPVQNOTORIZEOTO:Mr, John Fi Stolz'ROM;PG&ESan Francisco, Ca, 9/I106:Philip A, CraneINPUT FORMOATE OF OOCUMENT2-22-78OATP RPSEI')(8ONUMB...
UNITED STATES NUCLEAR REGULATORY COMMISSION REGION IV 1600 E. LAMAR BLVD. ARLINGTON, TX 76011-4511 August 2, 2016 Mr. Edward D. Halpin Senior Vice President, Generation and Chief Nuclear Officer Pacific Gas and Electric Company Diablo Canyon Power Plant P.O. Box 56, Mail Co...
'. .',f .', =...S.IMMARY AND EVALUATION REPORT',Report Title:Diablo Canyon Unit 1 Independent Design VerificationProgram, HVAC Components'.Report No.ITR-31, P 105-4-839-031, Revision 0.,'Report Date1/14/83AuthorRobert L. Cloud AssociatesEdward Denison Project Manager8310180624...
GE Hitachi Nuclear Energy AmericasDiablo Canyon Power PlantHead Loss and Chemical Effects Testing Program2August 23,2007Overview• Chemical effects testing conducted for Diablo Canyon Power Plant (DCPP)• Plenum style strainer with ~3300 ft² of perforated area allows open area f...
August 26, 2016 Mr. Edward D. Halpin, Senior Vice President, Generation and Chief Nuclear Officer Pacific Gas and Electric Company Diablo Canyon Power Plant P.O. Box 56, Mail Code 104/6 Avila Beach, CA 93424 SUBJECT: DIABLO CANYON POWER PLANT – NRC PROBLEM IDENTIF...
Pacific Gas and Electric Company® May 18, 2017 PG&E Letter DCL-17-049 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Docket No. 50-323, OL-DPR-82 Diablo Canyon Unit 2 James M. Welsch Vice President, Nuclear Generation Flaw Evaluation o...
/~or em et ec~ 3n c.CON SLILTING ENGINEERSELM GROVE, WISCONSINPAR: PQP-124Page 1 of 9ll Total Pages,with AttachmentPARAMETER, Inc.»Ioject Quality Plan (PQP)fori::o';ii::;..-.,'..;:.:c',".c Services o~-Su oru I!RC/TE 'Recipe V personne]in. Gl (3c:sil. Uct ve Examinations and Re...
UNITED STATESNUCLEAR REGULATORY COMMISSIONgoN~r ~qqgacgg76~9g~ye /p@ocnATOMIC SAFETY AND LICENSING APPEAL-BOARDRichard S. Salzman, ChairmanDr..Lawrence R. QuarlesDr. N.'.ReedJohnson)In the Matter of))PACXFIC GAS AND ELECTRIC COMPANY))(Diablo Canyon Nuclear Power Plant,...
5&%CIVIC Cr&S AND ELECTRIC CO1VCPAM Z77 BEALE STREET ~SAN FRANCISCO, CALIFORNIA 94106 ~(415) 781.4211JOHN C ~ MORRISSSYYIoc oocCIocNT ANo acocoAL covN55LMAI COLM H ~ PURSUSHA55OCIACC OCNCCAL COVN5CI.CHARLCC T VAN OCVOCMMALCOLM A ~ M ~ OKILLOPPHII IP A ~ CRAN C, %IR ~HCNRY J, L...
April 30, 2018 Mr. James M. Welsch Vice President, Nuclear Generation and Chief Nuclear Officer Pacific Gas and Electric Company Diablo Canyon Power Plant P.O. Box 56, Mail Code 104/6 Avila Beach, CA 93424 SUBJECT: DIABLO CANYON POWER PLANT, UNITS 1 AND 2 - NOTIF...
RTS Instrumentation3.3.1ACTIONS (continued)CONDITION REQUIRED ACTION COMPLETION TIMEE. One channel inoperable. NOTEThe inoperable channel, or oneadditional channel for functions 6,7, and 8.b may be bypassed forup to 4 hours for surveillancetesting of other channels. Forfunctio...
I ,*** ISSUED FOR USE BY: DATE: EXPIRES:DIABLO CANYON POWER PLANT 1 &2 ENV.SW1ENVIRONMENTAL ENGINEERING PROCEDURE U Rev. 0Page 1 of 19Storm Water Management10/21/08Effective DateQUALITY RELATEDREFERENCE USETable of Contents1. S C O P E ............................................
QC)PA.C 1 P I C C'rA.SANDlP(R.~K~77 OEALE. STREET~SKLKC TR.IC COlVEHA.MZAN FRANCISCO, CALIFORNIA 94106~(415) 781~4211JOHN C. MOAAISSSVVICC FCCSIOCNT AND OCNCDAL COUNSELIYIALCOIM H. F UR GUSHASSOCIAIC SCNCEAL COSNSCLVVILLIAM 0, KUOCRCHAR LCS 7 VAN CSC U 8C NMALCOLMA. MDOKILI.OP...
5-15 INSTALLATION AND STRUCTURAL EVALUATION5.1 Conduct of ReviewThis chapter of the Safety Evaluation Report contains reviews of the information presented inthe Diablo Canyon ISFSI Safety Analysis Report Chapter 4, “ISFSI Design.” The objective ofthe installation design revi...
NRC NEWS U. S. NUCLEAR REGULATORY COMMISSION Office of Public Affairs Region IV 611 Ryan Plaza Drive - Suite 400 Arlington, TX 76011-4005No. IV-03-035 August 8, 2003Contact:...
-1- May 15, 2000PRELIMINARY NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE PNO-IV-00-011This preliminary notification constitutes EARLY notice of events of POSSIBLEsafety or public interest significance. The information is as initiallyreceived without verification or evaluation, ...
Docket Ho. 55-275Pacific Gas 5. E1ectric CompanyATTN: t'tr. R. D. Pamsay,Plant SuperintendentDiablo Canyon Power PlantP.O. Box 56Avilia Beach, California 9N24Gentlenen:This letter concerns the individuals who have applied for operator andsenior operator licenses for the Diablo...
OFFICIAL USE ONLY – SECURITY-RELATED INFORMATION “Enclosure transmitted herewith contains SUNSI. When separated from enclosure, this transmittal document is decontrolled.” OFFICIAL USE ONLY – SECURITY-RELATED INFORMATION February 17, 2012 John T. Conway Senior Vice ...
__ Pacific Gas and ~ :~ Electric Company® December 13, 2012 PG&E Letter DCL-12-126 U.S. Nuclear Regulatory Commission ATTN:- Document Control Desk Washington, DC 20555-001 Docket No. 50-275, OL-DPR-80 Docket No. 50-323, OL-DPR-82 Diablo Canyon Units 1 and 2 Barry S. Allen Site...
CATEGORY 1REGULAT Y INFORMATION DISTRIBUTIO SYSTEM (RIDS)ACCESSION NBR:9805050118 DOC.DATE: 97/12/31 NOTARIZED: NOFACIL:,50'75 Diablo Canyon Nuclear Power Plant, Unit 1, Pacific Ga%J-329; Diablo Canyon Nuclear Power Plant, Unit 2, Pacific GaAUTH.NP~CE"AUTHOR AFFILIATIONRUEGER,...
0 oUNITED STATES NUCLEAR REGULATORY COMMISSION X ,WASHINGTON, D. C. 20555 January 22, 1992 Docket Nos. 50-275 and 50-323 Mr. Gregory M. Rueger Senior Vice President and General Manager Nuclear Power Generation Business Unit Pacific Gas and Electric Company 77 Beale Street, Roo...
E 11Pacific Gas andElectric Company'James B. Becker Diablo Canyon Power PlantVice President P. 0. Box 56Diablo Canyon Operations and Avila Beach, CA 93424Station Director805.545.3462July 29, 2005 Fax: 805.545.4234PG&E Letter DCL-05-080U.S. Nuclear Regulatory CommissionATTN: Do...
NRC ANNOUNCES OPPORTUNITY FOR HEARING ON APPLICATION TO RENEW OPERATING LICENSES FOR DIABLO CANYON NUCLEAR POWER PLANT The Nuclear Regulatory Commission has announced the opportunity to request a hearing on an application to renew the operating licenses for Diablo Canyon Nu...