Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Part 21 Reports - 2007

This page includes links to files in non-HTML format. See Plugins, Viewers, and Other Tools for more information.

Log No Notifier Description Report Date Event No. / Accession No.
2007-37-00 Phi-Delta Steel Channel Shear Center Eccentricity Misstored in PD STRUDL Program 12/24/2007 ML080070361
2007-36-01 Invensys Testing Deficiency in Commercial Dedication Process 04/04/2008 ML080990634
2007-36-00 Invensys Testing Deficiency in Commercial Dedication Process 12/19/2007 ML073550112
2007-35-00 Fisher Controls Potentially Insufficient Thread Engagement For Certain Rosemount Pressure Transmitters 12/06/2007 ML073440211
2007-34-00 Fisher Controls Missing Qualification Documentation for ASME Weld Repair 11/21/2007 ML073310381
2007-33-00 Farley Areva 4160V Breaker C-Clip 11/14/2007 ML073200131
2007-32-00 CONVAL, Inc. Conval Valve Weld Qualifications 11/09/2007 ML073200086
2007-31-00 Cooper Nuclear Station High Pressure Coolant Injection Inverter Circuit Failure 05/23/2007 ML071500103
2007-30-00 Enertech Affected Response Time for Cartridge Solenoid Valve, Part No. C9113S 10/25/2007 EN 43748
ML073030464
2007-29-00 Areva Nonconservative Calculation of Minimum Critical Power Ratio 10/08/2007 EN 43701
ML072830334
2007-28-00 Beaver Valley MSIV Pilot Poppet Nut and Stem Vibration-Induced Wear 10/01/2007 ML072760115
2007-27-04 Transnuclear Inadequate Welding Records for Dry Fuel Storage Cask 03/03/2008 ML080650194
2007-27-03 Transnuclear Inadequate Welding Records for Dry Fuel Storage Cask 01/04/2008 ML080080060
2007-27-02 Transnuclear Inadequate Welding Records for Dry Fuel Storage Cask 12/20/2007 EN 43666
2007-27-01 Transnuclear Inadequate Welding Records for Dry Fuel Storage Cask 11/05/2007 ML073110519
2007-27-00 Transnuclear Inadequate Welding Records for Dry Fuel Storage Cask 09/26/2007 ML072750342
2007-26-00 ABB Electroswitch Corp. Assembly Missing a Spacer Bushing 09/25/2007 ML072690416
2007-25-00 MPR Associates Analog Electronic Circuit Card in Basler EDG Voltage Regulators 09/21/2007 ML072750470
2007-24-00 Rosemount Calibration of Certain Model 1154 Pressure Transmitters 08/14/2007 ML072330475
2007-23-01 Oconee Incorrect Alignment of Contacts in Magnecraft Struthers-Dunn Relay (Part Number 219ABAP-115/125D) 09/06/2007 ML072630547
2007-23-00 Oconee Incorrect Assembly of Contacts in Magnecraft Struthers-Dunn Relay (Part Number 219ABAP-1 15/125D) 08/09/2007 EN 43558
2007-22-00 Westinghouse Material Hardness of Closing Solenoid Moving Core Relay Release Arm on DB-25 Circuit Breaker 08/02/2007 ML072180044
2007-21-00 North Anna High Internal Resistance Readings of EDG Battery Cells 07/27/2007 EN 43527
ML072120325
2007-20-01 General Electric

Nonconservatism in GE STRM Thermal-Mechanical Methodology

(Enclosure 1 is proprietary and not publicly available.)
01/04/2008 ML080100670
2007-20-02 General Electric

Nonconservatism in GE STRM Thermal-Mechanical Methodology--Extension to GNF2 Fuel Design

(Enclosure 1 is proprietary and not publicly available.)
08/28/2008 ML082420310
2007-20-00 General Electric

Nonconservatism in GE STRM Thermal-Mechanical Methodology

(Enclosure 1 is proprietary and not publicly available.)
01/21/2007 ML072290203
2007-19-00 Westinghouse Transfer of Information: NSAL-07-2, "Revised Seismic Level for Type A200 Size 1 and Size 2 Motor Starters and Contactors" (Non-proprietary) 07/25/2007 ML072080118
2007-18-00 Calvert Cliffs EDG Short-Time Overcurrent Amptector Setpoint Too Low 12/26/2006 ML070030501
2007-17-00 Fisher Controls International Regulator Screw (Fisher Part No. T13526T0012) Fractures in Certain Instrument Air Regulators 07/03/2007 EN 43472
2007-16-00 Engine Systems Cracking in Camfil-Farr Air Intake Filter Housing, P/N: ES150801 -1, for Emergency Diesel Engines 06/26/2007 ML071840176
2007-15-00 Carboline Coatings Test Standard 06/05/2007 EN 43412
2007-14-00 Flowserve Borg Warner Swing Check Valve Disc Assemblies 05/17/2007 ML071430262
2007-13-00 Varflex Electrical Insulating Sleeving 05/17/2007 EN 43370
2007-12-01 Velan Incorrect Piston Check Valve Flow Coefficient (Cv) Information 11/16/2007 ML073532221
2007-12-00 Velan Incorrect Piston Check Valve Flow Coefficient (Cv) Information 03/07/2007 ML071370309
2007-11-01 Dresser, Inc. Potential Defect Involving Power Actuated Pressure Relief Valves Supplied to Calvert Cliffs, Ft. Calhoun, and Oconee Plants 07/13/2007 ML071990539
2007-11-00 Dresser, Inc. Potential Defect Involving Power Actuated Pressure Relief Valves Supplied to Calvert Cliffs, Ft. Calhoun, and Oconee Plants 04/27/2007 ML071230090
2007-10-00 Fairbanks Morse Engine Diesel Cam Roller Bushing Failures 04/09/2007 EN 43294
ML071010125
2007-09-00 Rosemount Nuclear Instruments, Inc. Certain Model 1152 Pressure Transmitters May Exhibit Leakage if Subjected to Pressures Greater than 2000 psi 04/06/2007 ML071000229
2007-08-00 Rosemount Nuclear Instruments, Inc. Rosemount Pressure Transmitter May Not Be Seismically Qualified 03/30/2007 ML070930381
2007-07-00 Nuclear Management Co. Replacement Battery Post Seal Corrosion Issues 03/28/2007 ML070871089
2007-06-00 Fairbanks Morse Defect in Woodward Governor Pivot Pin 03/14/2007 EN 43235
ML070740695
2007-05-00 Tyco Electronics Potential Defect in E7000 Relays 03/07/2007 EN 43218
ML070680288
2007-04-00 Carrier Co. Chiller Copper Sleeve Cracks Leading to Slow Refrigerant Discharge 02/27/2007 EN 43190
ML070640253
2007-03-00 CONVAL, Inc. Material Verifications on High Pressure and Temperature Steam and Water Globe Valves 02/14/2007 EN 43166
2007-02-00 United States Enrichment Corporation Defect in a Continental Brake Model No. 95400 Crane 01/05/2007 EN 43080
ML070090491
2007-01-00 Duane Arnold Nuclear Power Plant Potential Degradation of Hydraulic Snubber Fluid 01/03/2007 EN 43071
ML070180491
ML070300154