UNITED STATES NUCLEAR REGULATORY COMMISSION REGION I 2100 RENAISSANCE BLVD., SUITE 100 KING OF PRUSSIA, PA 19406-2713 April 20, 2020 Ms. Pamela B. Cowan Senior Vice President & Chief Operating Officer Holtec Decommissioning International, LLC Krishna P. Singh Technol...
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 April 2, 2015 Ms. Kimberly Manzione, P.E. Holtec International Holtec Center One Holtec Drive Marlton, NJ 08053 SUBJECT: CERTIFICATE OF COMPLIANCE NO. 1040 FOR THE HI-STORM UMAX CASK STORAGE SYS...
HI-STORE Consolidated Interim Storage Facility Holtec International Docket No. 72-1051 STATE OF NEW JERSEY ss: COUNTY OF CAMDEN Kimberly Manzione, being duly sworn, deposes and says: That she has read the attached application and the matters stated therein are true and correct...
SEuM.HOLTECINTERNATIONALHoltec Center, 555 Lincoln Drive West, Marlton, NJ 08053Telephone (856) 797-0900Fax (856) 797-0909January 10, 2007U.S. Nuclear Regulatory CommissionATTN: Document Control DeskWashington, DC 20555-0001Reference:Subject:Dear Sir:1. USNRC Docket No. 71-932...
1, it IU mHoltec Center, 555 Lincoln Drive West, Marlton, NJ 08053H O LT E C Telephone (856) 797-0900IN T ER.N-AT IO N A L Fax (856) 797-0909Mr. John Goshenc/o Document Control DeskU. S. Nuclear Regulatory CommissionWashington, DC 20555-0001May 23, 2012Subject: Submittal of Re...
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 August 8, 2017 PUBLIC MEETING NOTICE Organization: Holtec International, Inc. Date: August 21, 2017, 2:00 p.m. - 4:00 p.m. Location: U.S. Nuclear Regulatory Commission (NRC) Two White Flint...
July 14, 2003Mr. Brian GuthermanLicensing ManagerHoltec InternationalHoltec Center, 555 Lincoln Drive WestMarlton, NJ 08053SUBJECT: PUBLIC DISCLOSURE DETERMINATION (TAC NO. L23399)Dear Mr. Gutherman:By letter dated June 4, 2002, Pacific Gas and Electric Company (PG&E) submitt...
NON-PROPRIETARY VERSION SAFETY ANALYSIS REPORT on THE HI-STAR 100 CASK SYSTEM (Holtec International Storage, Transport, And Repository Cask System) (Revision 18) by Holtec International Krishna P. Singh Technology Campus 1 Holtec Blvd Camden, NJ 08104 (holtecinternatio...
January 20, 2010 Ms. Tammy S. Morin, Manager Licensing Manager Holtec International 555 Lincoln Drive West Marlton, NJ 08053 SUBJECT: HOLTEC INTERNATIONAL (HOLTEC), REQUEST FOR WITHHOLDING INFORMATION FROM PUBLIC DISCLOSURE (TAC NO. L24321) Dear Ms. Morin: By letter...
Attachment 1 to Holtec Letter 5018050 Amendment Request 1032-5, REVISION 0 SUMMARY OF PROPOSED CHANGES Page 1 of 3 All changes to the CoC are marked in the subsequent attachments. Changes that have occurred as part of prior applications are not marked as changes. Propose...
U.S. Nuclear Regulatory C01mnission ATTN: Document Control Desk Document ID 2767002-NRC Non-Proprietary Enclosure 11 AFFIDAVIT PURSUANT TO 10 CFR 2.390 I, Kimberly Manzione, being duly sworn, depose and state as follows: (1) I have reviewed the information described in paragra...
NON-PROPRIETARY VERSION SAFETY ANALYSIS REPORT on THE HI-STAR 100 CASK SYSTEM (Holtec International Storage, Transport, And Repository Cask System) (Revision 16.A) by Holtec International Holtec Center One Holtec Drive Marlton, NJ 08053 (holtecinternational.com) USN...
January 12, 2010 Ms. Tammy Morin, Licensing Manager Holtec International Holtec Center 555 Lincoln Drive West Marlton, NJ 08053 SUBJECT: ACCEPTANCE REVIEW OF LICENSE AMENDMENT REQUEST NO. 8 TO HOLTEC INTERNATIONAL HI-STORM 100 CERTIFCATE OF COMPLIANCE NO. 1014 (TAC N...
HOLTEC INTERNATIONAL June 25, 2018 Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Mr. Jose Cuadrado, Project Manager Division of Spent Fuel Management Office ofNuclear Material Safety and Safeguards Docket Numbe...
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 August 6, 2018 MEETING NOTICE Organization: Holtec International, Inc. (Holtec) Date: August 24, 2018 9:00 a.m. – 11:00 a.m. Location: U.S. Nuclear Regulatory Commission (NRC) One White ...
Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 HDI-OC-20-076 10 CFR 50.54(w) September 15, 2020 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555 Oyster...
a generation ahead by design HI-SMUR 140 Presentation to NRC July 21, 2011 1 By Dr. Stefan Anton, Vice President of Engineering Holtec International 555 Lincoln Drive West Marlton, NJ 08053 Telephone: 856-797-0900 . a generation ahead by design • Introduction / Go...
July 29, 2014 Dr. Stefan Anton Licensing Manager Holtec International Holtec Center One Holtec Drive Marlton, NJ 08053 SUBJECT: HOLTEC INTERNATIONAL HI-STORM UMAX CANISTER STORAGE SYSTEM, CERTIFCATE OF COMPLIANCE NO. 1040, AMENDMENT NO. 1 - ACCEPTED FOR REVIEW (TAC NO....
U.S. Nuclear Regulatory Commission Document ID 5026004 Non-Proprietary Enclosure 12 AFFIDAVIT PURSUANT TO 10 CFR 2.390 I, Kimberly Manzione, being duly sworn, depose and state as follows: ( 1) I have reviewed the information described in paragraph (2) which is sought to be wit...
U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Document ID 2404014-NRC Non-Proprietary Enclosure 4 AFFIDAVIT PURSUANT TO 10 CFR 2.390 I, Kimberly Manzione, being duly sworn, depose and state as follows: (1) I have reviewed the information described in paragraph...
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 September 22, 2020 Ms. Kimberly Manzione, Licensing Manager Holtec International Holtec Technology Campus One Holtec Boulevard Camden, NJ 08104 SUBJECT: HOLTEC INTERNATIONAL’S APPLICATION FOR SPECIFIC INDE...
August 17, 2011 Ms. Tammy S. Morin Licensing Manager Holtec International 555 Lincoln Drive West Marlton, NJ 08053 SUBJECT: HOLTEC INTERNATIONAL REQUEST FOR WITHHOLDING INFORMATION FROM PUBLIC DISCLOSURE (TAC NO. L24515) Dear Ms. Morin: By letter dated July 28, 2011,...
K. UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 March 21, 2016 Ms. Kimberly Manzione, P.E. Holtec International Holtec Center One Holtec Drive Marlton, NJ 08053 SUBJECT: CERTIFICATE OF COMPLIANCE NO. 1014, AMENDMENT NO. 9, REVISION NO. ...
Attachment 1 to Holtec Letter 5025054 Holtec Responses to NRC Clarification Questions on Emergency Plan RAI EP-3-S: Justify the inclusion of additional Emergency Action Levels (EALs) into the ISFSI EAL scheme for the HI-STORE CISF Emergency Response Plan (ERP) In its response...
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 February 6, 2015 Dr. Stefan Anton Licensing Manager Holtec International 555 Lincoln Drive West Marlton, NJ 08053 SUBJECT: HOLTEC INTERNATIONAL REQUEST FOR WITHHOLDING INFORMATION FROM PUBLIC...