Holtec Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Document ID 5025029 Page 1 of 2 June 27, 2018 Mr. Jose Cuadrado Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory...
December 3, 2018 UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION Before the Atomic Safety and Licensing Board In the Matter of ) ) Docket No. 72-1051 Holtec International ) ) (HI-STORE Consolidated Interim Storage ) Facility) ) Holtec International’s Answer...
M U UNE M Holtec Center, 555 Lincoln Drve West, Mariton, NJ 08053H O LT E C Telephone (856) 797-0900INTERNATIONAL Fax (856) 797-0909December 30, 2005U.S. Nuclear Regulatory CommissionATMN: Document Control Desk,Director, Spent Fuel Project Office,Office of Nuclear Material Saf...
4845-3026-2906.v1 November 8, 2018 UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION Before the Atomic Safety and Licensing Board In the Matter of ) ) Docket No. 72-1051 Holtec International ) ) HI-STORE Consolidated Interim Storage ) Facil...
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 December 26, 2019 MEETING NOTICE Organization: Holtec International, Inc. (Holtec) Date: January 15, 2020 1:00 p.m. – 3:00 p.m. (Eastern Standard Time) Location: U.S. Nuclear Regulatory Commi...
October 24, 2001Mr. Brian GuthermanLicensing ManagerHoltec International555 Lincoln Drive WestMarlton, NJ 08053SUBJECT: PUBLIC DISCLOSURE DETERMINATION Dear Mr. Gutherman:On June 14, 2001, Holtec International (Holtec) submitted information to the Nuclear RegulatoryCommission...
Summary of Proposed Changes (SOPC) for LAR 9373-1 Proposed Change #1 Revise loading Configuration 3 (Table 7.C.5) for MPC-37 to include the following options for fuel assembly class 16x16C: a) 2 Damaged Fuel Containers (DFCs) containing fuel debris (up to 37 rods per DFC), 10 ...
•• HOLTEC INTERNATIONAL April 13, 2020 Chris Jacobs Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Sa...
m m m m mHoltec Center, One Holtec Drive, Mariton, NJ 08053Telephone (856) 797-0900INTERNATI ONALDecember 18, 2015Mr. Mark LombardDivision of Spent Fuel ManagementOffice of Nuclear Material Safety and SafeguardsU.S. Nuclear Regulatory CommissionATTN: Document Control DeskWashi...
OFFICIAL USE ONLY – PROPRIETARY INFORMATION OFFICIAL USE ONLY – PROPRIETARY INFORMATION NOTICE: The Enclosure transmitted herewith contains Official Use Only - Proprietary Information. When separated from the Enclosure, this transmittal document is decontrolled. Novembe...
September 6, 2019 Pamela B. Cowan Senior Vice President and Chief Operating Officer Holtec Decommissioning International, LLC Krishna P. Singh Technology Campus 1 Holtec Blvd. Camden NJ 08104 SUBJECT: ELECTRICAL EQUIPMENT HARVESTING FROM OY...
May 18, 2005
Mr. Paul D. Hinnenkamp
Vice President - Operations
Entergy Operations, Inc.
River Bend Station
5485 US Highway 61N
St. Francisville, LA 70775
SUBJECT: INSPECTION REPORT 050-00458/05-009; 072-00049/05-001
Dear Mr. Hinnenkamp:
An NRC inspection was conducted ...
RAI Responses CHAPTER 1 GENERAL INFORMATION 1-1 Clarify the references in the application regarding the MPC Enclosure Vessel Drawing No. 3923. Drawing No. 3923 Notes 4 and 11 contain unclear references to the “SAR (Transportation)” and “FSAR (Storage)” regarding componen...
4813-8745-0795.v3 November 18, 2019 UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION Before the Commission In the Matter of ) ) Docket No. 72-1051 Holtec International ) ) (HI-STORE Consolidated Interim Storage ) Facility) ) HOLTEC INTERNATIONAL’S ANSWER OPPOSI...
HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL REPORT HI-2114830 Proposed Rev. 6.D 1-41 comparable to its counterpart in the HI-STORM 100 system. The material of construction of the pressure retaining components is also identical (options of stainless steels, denoted as Alloy X, ...
4828-2648-5378.v1 UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION Atomic Safety and Licensing Board In the Matter of ) ) Docket No. 72-1051 Holtec International ) ) ASLBP No. 18-958-01-ISFSI-BD01 (HI-STORE Consolidated Interim Storage ) Facility) ) Holtec Inte...
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 May 3, 2016 Ms. Kimberly Manzione, P.E. Licensing Manager Holtec International Holtec Center One Holtec Drive Marlton, NJ 08053 SUBJECT: ISSUANCE OF CORRECTED APPENDIX A, TABLE 3-1 FOR AMENDMENT NO....
September 14, 2006Dr. Stefan AntonLicensing ManagerHoltec International555 Lincoln Drive WestMarlton, NJ 08053SUBJECT: NRC REJECTION OF HOLTEC INTERNATIONAL’S REQUEST FORWITHHOLDING INFORMATION FROM PUBLIC DISCLOSURE FOR HOLTECREPORTS HI-2043317 REVISION 3 AND HI-2043168 REVIS...
••••• HOLTEC INTERNATIONAL March 14, 2019 Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Pierre Saverot, Project Manager- Spent Fuel Licensing Branch Division of Spent Fuel Management Office of Nuclear Material ...
MElEMHOLTECINTERNATIONALHoltec Center, 555 Lincoln Drive West, Marlton, NJ 08053Telephone (856) 797-0900Fax (856) 797-0909U. S. Nuclear Regulatory CommissionATTN: Document Control Desk, Director, Nuclear Material Safety and SafeguardsDocument ID 5014654June 23, 2008Subject: Fo...
May 22, 2020 Kimberly Manzione Licensing Manager 1 Holtec Boulevard Camden, NJ 08104 SUBJECT: ACCEPTANCE FOR REVIEW OF HOLTEC INTERNATIONAL THERMAL TOPICAL REPORT ON THE HI-STORM 100 AND HI-STORM FW SYSTEMS (EPID: L-2020-TOP-0018) Dear Ms. Manzione: By letter dated Ma...
No: 20-057 November 23, 2020
CONTACT: Scott Burnell, 301-415-8200
NRC Approves License Transfer for Indian Point Nuclear Power Plant
The Nuclear Regulatory Commission has approved the transfer of the Indian Point nuclear
power plant licenses from Entergy Nuclear Opera...
January 8, 2003 Mr. Brian GuthermanLicensing ManagerHoltec International555 Lincoln Drive WestMarlton, NJ 08053SUBJECT: REQUEST FOR ADDITIONAL INFORMATION - HOLTEC HI-STORM 100 ASME CODE ALTERNATIVEDear Mr. Gutherman:On October 22, 2002, and supplemented by letter dated Novemb...
M E lE M Holtec Center, 555 Lincoln Drive West, Marlton, NJ 08053H O LT E C Telephone (856) 797-0900INTERNATIONAL Fax (856) 797-0909April 18, 2013John Goshen, P.E., Project Manager - Licensing BranchDivision of Spent Fuel Storage and TransportationOffice of Nuclear Material Sa...
Holtec Center, One Holtec Drive, Marlton, NJ 08053 Telephone (856) 797-0900 Fax (856) 797-0909 Document ID 5014811 Page 1 of 2 June 14, 2016 Mr. Mark Lombard Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commis...