January 21, 2010 Ms. Tammy S. Morin, Manager Licensing Manager Holtec International 555 Lincoln Drive West Marlton, NJ 08053 SUBJECT: HOLTEC INTERNATIONAL (HOLTEC), REQUEST FOR WITHHOLDING INFORMATION FROM PUBLIC DISCLOSURE (TAC NO. L24398) Dear Ms. Morin: By letter...
Enclosure 6PG&E Letter DCL-04-149Holtec Licensing Report HI-2043162 Rev. I (Non-proprietary)SPENT FUEL STORAGE EXPANSIONatDIABLO CANYON POWER PLANTforPACIFIC GAS AND ELECTRIC CO.HOLTEC PROJECT NO. 1368HOLTEC REPORT HI-2043162REPORT CATEGORY: AREPORT CLASS: SAFETY RELATEDCOMPAN...
HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL REPORT HI-2114830 Proposed Rev. 6.G 9-50 7. Place HI-TRAC VW in the spent fuel pool as follows: If necessary for plant weight limitations, drain the water from the neutron shield jacket. For HI-TRAC VW Version V2, unbolt the HI-T...
September 14, 2006Mr. Evan RosenbaumProject ManagerHoltec International555 Lincoln Drive WestMarlton, NJ 08053SUBJECT: NRC DETERMINATION OF HOLTEC INTERNATIONAL’S REQUEST FORWITHHOLDING INFORMATION FROM PUBLIC DISCLOSURE (TAC NO.L23850)Dear Mr. Rosenbaum:By your letter dated J...
HI-STAR 190 SAR Proposed Revision 0.A Report HI-2146214 1.2-8 1.2.1.5 Neutron and Gamma Shielding Features The HI-STAR 190 Cask Containment is circumscribed by the Gamma Capture Space (GCS) and the Neutron Capture Space (NCS), described in the foregoing, that respectivel...
L ••••• HOLTEC Holtec Technology Campus, 1 Holtec Blvd, Camden, NJ 08104 INTERNATIONAL June 8, 2017 Pierre Saverot, Project Manager Spent Fuel Licensing Branch Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards A TIN: Document Control Desk U.S. ...
• HOLTEC Holtec Center, One Holtec Drive, Marlton, NJ 08053 INTERNATIONAL August 30, 2016 Mr. Mark Lombard Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-000...
September 18, 2013 Dr. Stefan Anton Acting Licensing Manager Holtec International 555 Lincoln Drive West Marlton, NJ 08053 SUBJECT: HOLTEC INTERNATIONAL REQUEST FOR WITHHOLDING INFORMATION FROM PUBLIC DISCLOSURE (TAC NO. L60542) Dear Dr. Anton: By letter dat...
Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 HOLTEC INTERNATIONAL May 29, 2019 Pierre Saverot, Project Manager - Spent Fuel Licensing Branch Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards ATTN: Document Control Desk U...
November 22, 2010 Ms. Tammy S. Morin, Manager Licensing Manager Holtec International 555 Lincoln Drive West Marlton, NJ 08053 SUBJECT: HOLTEC INTERNATIONAL (HOLTEC), REQUEST FOR WITHHOLDING INFORMATION FROM PUBLIC DISCLOSURE (TAC NO. L60542) Dear Ms. Morin: By lette...
April 22, 2010 Ms. Tammy S. Morin Licensing Manager Holtec International 555 Lincoln Drive West Marlton, NJ 08053 SUBJECT: HOLTEC INTERNATIONAL (HOLTEC), REQUEST FOR WITHHOLDING INFORMATION FROM PUBLIC DISCLOSURE (TAC NO. L24321) Dear Ms. Morin: By letter dated April...
June 12, 2009 Ms. Tammy Morin Acting Licensing Manager Holtec International 555 Lincoln Drive West Marlton, NJ 08053 SUBJECT: PRELIMINARY CERTIFICATE OF COMPLIANCE AND SAFETY EVALUATION REPORT FOR AMENDMENT NO. 7 TO CERTIFICATE OF COMPLIANCE 72-1014 FOR THE HI-...
7.0CHAPTER 7t: CONFINEMENTINTRODUCTIONConfinement of all radioactive materials in the HI-STORM 100 System is provided by the MPC.The design ofthe HI-STORM 100 confinement boundary assures that there are no credible designbasis events that would result in a radiological release...
MENEMHOLTECINTERNATIONALHoltec Center, 555 Lincoln Drive West, Marlton, NJ 08053Telephone (856) 797-0900Fax (856) 797-0909November 26, 2013John Goshen, P.E., Project Manager - Licensing BranchDivision of Spent Fuel Storage and TransportationOffice of Nuclear Material Safety an...
One Holtec Drive, Marlton, NJ 08053 HOL TEC INTERNATIONAL Telephone (856) 797-0900 Fax (856) 797-0909 August 19, 2016 Pierre Saverot, Project Manager Spent Fuel Licensing Branch Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards ATTN: Document C...
* 1 1 * * _*Holtec Center, 555 Lincoln Drive West, Mariton, NJ 08053Telephone (856) 797-0900H OLTE C Fax (856) 797-0909INTERNATIONALDecember 23, 2004U.S. Nuclear Regulatory CommissionATTN: Document Control DeskWashington, DC 20555-0001Subject: USNRC Docket No. 72-1008HI-STAR 1...
February 7, 2013 Mr. Terry Sensue Licensing Manager Holtec International 555 Lincoln Drive West Marlton, NJ 08053 SUBJECT: U.S. NUCLEAR REGULATORY COMMISSION APPROVAL OF HOLTEC INTERNATIONAL, REQUEST FOR WITHHOLDING INFORMATION FROM PUBLIC DISCLOSURE (TAC NO. L24715) De...
4840-5038-7342.v1 March 22, 2019 UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION Before the Atomic Safety and Licensing Board In the Matter of ) ) Docket No. 72-1051 Holtec International ) ) ASLBP No. 18-958-01-ISFSI-BD01 HI-STORE Consolidated Interim Storage ...
4817-1123-7751.v1 October 9, 2018 UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION Before the Commission In the Matter of ) ) Docket No. 72-1051 Holtec International ) ) (HI-STORE Consolidated Interim Storage ) Facility) ) Holtec International’s Answer Oppos...
Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900Fax (856) 797-0909 Document ID 5025044 Page 1 of 1 May 13, 2019 Jill Caverly, Senior Project Manager U.S. Nuclear Regulatory Commission Office of Nuclear Material Safety and Safe...
Definitions 1.1 Certificate of Compliance No. 1032 Amendment No. 54 Appendix A 1.1-3 1.1 Definitions Term Definition assemblies, instrument tube tie rods (ITTRs), vibration suppressor inserts, and components of these devices such as individual rods. OVERPACK OVERPA...
Approved Contents 2.0 Certificate of Compliance No.1032 Amendment No. 32 Appendix B 2-20 2.4 Burnup Credit Criticality control during loading of the MPC-37 is achieved through either meeting the soluble boron limits in LCO 3.3.1 OR verifying that the assemblies meet the mini...
Responses to HI‐STORM 100 Amendment 13 Requests for Additional Information RSI 5-1: Provide a summary of: a. all design and operational changes described in the licensing basis for the HI-STORM 100 casksystem from Amendment No. 2 forward, and b. the information to be include...
••••• HOLTEC INTERNATIONAL February 23, 2018 Mr. Michael Layton, Director Division of Spent Fuel Management Holtec Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797 -0900 Fax (856) 797-0909 Office of Nuclear Material Safety and Safeguards U.S. Nuclear Reg...
Enclosure 2 to Holtec Letter 5024006 Page 1 of 82 Response to Request for Additional Information Holtec International Docket No. 71-9373 HI-STAR 190 Transportation Package Chapter 1 – General Information Licensing Drawings NRC RAI 1-1 1-1 Revise licensing drawing No. 9...