Circulating Water System 4.9-1/2STP 3 & 4 Tier 14.9 Circulating Water SystemThe information in this section of the reference ABWR DCD is incorporated by reference with no departures or supplements.Rev. 06
Table of Contents TOC-1/2STP 3 & 4 Departures ReportTable of Contents1.0 Introduction .................................................................................................................. 1.1-11.1 Purpose...............................................................
Rev. 12 STP 3 & 4 Technical Specifications TOC-1/2 Table of Contents 1.0 Use and Application 2.0 Safety Limits (SLs) with Bases 3.0 Limiting Condition for Operation (LCO) Applicability and Surveillance Require-ment (SR) Applicability with Bases 4.0 Design Features 5....
Design Goals and Design Bases 18.2-1/2STP 3 & 4 Final Safety Analysis Report18.2 Design Goals and Design BasesThe information in this section of the reference ABWR DCD is incorporated by reference with no departures or supplements.Rev. 12
Basic Geologic and Seismic Information 2.5S.1-125STP 3 & 4 Final Safety Analysis Report Tier 2Figure 2.5S.1-37 Structure Contour Map of Stratum C (Silty Sand)Rev. 13 2.5S.1-126 Basic Geologic and Seismic InformationSTP 3 & 4 Final Safety Analysis Report Tier 2Figure 2.5S.1-38...
Decrease in Reactor Coolant System Flow Rate 15.3-1/2STP 3 & 4 Final Safety Analysis Report Tier 215.3 Decrease in Reactor Coolant System Flow RateThe information in this section of the reference ABWR DCD, including all subsections, tables, and figures, is incorporated by ref...
Piping Design 3.3-1/2STP 3 & 4 Tier 13.3 Piping DesignThe information in this section of the reference ABWR DCD, including all tables, is incorporated by reference with no departures or supplements.Rev. 12
Circulating Water System 4.9-1/2STP 3 & 4 Tier 14.9 Circulating Water SystemThe information in this section of the reference ABWR DCD is incorporated by reference with no departures or supplements.Rev. 12
Habitability Systems 6.4-1/2STP 3 & 4 Final Safety Analysis Report 6.4 Habitability SystemsThe information in this section of the reference ABWR DCD, including all subsections, tables, and figures, is incorporated by reference with the following departure and supplement.STD D...
Fire Protection Probabilistic Risk Assessment 19M-1STP 3 & 4 Final Safety Analysis Report19M Fire Protection Probabilistic Risk AssessmentThe information in this appendix of the reference ABWR DCD, including all subsections, tables, and figures is incorporated by reference wi...
Tunnels 3.12-1/2STP 3 & 4 Final Safety Analysis Report3.12 TunnelsThe information in this section of the reference ABWR DCD, including all subsections, is incorporated by reference with no departures or supplements.Rev. 12
Onsite Power Systems 8.3-1STP 3 & 4 Final Safety Analysis Report8.3 Onsite Power SystemsThe information in this section of the reference ABWR DCD including all subsections, tables, and figures is incorporated by reference with the following departures and supplements.STD DEP ...
Systems Required for Safe Shutdown 7.4-1STP 3 & 4 Final Safety Analysis Report7.4 Systems Required for Safe ShutdownThe information in this section of the reference ABWR DCD, including all subsections, tables and figures, is incorporated by reference with the following depart...
Verification Programs 14.0S-1/2STP 3 & 4 Final Safety Analysis Report14.0S Verification ProgramsSection 14.1S identifies specific information to be addressed for the Initial Test Program.Section 14.2 describes the initial test program, including pre-operational testing, initi...
Guidelines for LBB Application 3E-1/2STP 3 & 4 Final Safety Analysis Report3E Guidelines for LBB ApplicationThe information in this appendix of the reference ABWR DCD, including all subsections, tables and figures, is incorporated by reference with the following departure and...
Corium Shield 19ED-1/2STP 3 & 4 Final Safety Analysis Report19ED Corium ShieldThe information in this appendix of the reference ABWR DCD, including all subsections, tables, and figures, is incorporated by reference with no departures or supplements.Rev. 12
Spent Fuel Pool Geometry and Dose Rate Calculation 12B-1STP 3 & 4 Final Safety Analysis Report12B Spent Fuel Pool Geometry and Dose Rate CalculationThis Appendix provides site-specific information regarding the Spent Fuel Pool (SFP) geometry and methodology used to generate S...
Radioactive Waste System 2.9-1/2STP 3 & 4 Tier 12.9 Radioactive Waste SystemThe information in this section of the reference ABWR DCD, including all tables and figures, is incorporated by reference with no departures or supplements.Rev. 12
Control Room Standard Design Features 18.4-1STP 3 & 4 Final Safety Analysis Report18.4 Control Room Standard Design FeaturesThe information in this section of the reference ABWR DCD, including all subsections, is incorporated by reference with the following departures.STD DEP...
Basic Geologic and Seismic Information 2.5S.1-129STP 3 & 4 Final Safety Analysis ReportFigure 2.5S.1-41 Structure Contour Map of Stratum H (Silty Sand)Rev. 12 2.5S.1-130 Basic Geologic and Seismic InformationSTP 3 & 4 Final Safety Analysis ReportFigure 2.5S.1-42 Site Vicinit...
Summary Description 10.1-1STP 3 & 4 Final Safety Analysis Report10.0 Steam and Power Conversion SystemThe information in this section of the reference ABWR DCD, including all subsections, tables and figures, is incorporated by reference with the following departures and suppl...
Transportation Accidents 7.4-1STP 3 & 4 Environmental Report7.4 Transportation AccidentsA description of the methodology used to analyze the environmental impacts associated with the transportation of radioactive materials, including accidents, is provided in Subsection 5.11....
Yard Structures and Equipment 2.16-1/2STP 3 & 4 Tier 12.16 Yard Structures and EquipmentThe information in this section of the reference ABWR DCD, including all subsections, tables, and figures, is incorporated by reference with no departures or supplements.Rev. 10
Requirements for Determination of ABWR Site Acceptability 2.2-1/2STP 3 & 4 Final Safety Analysis Report2.2 Requirements for Determination of ABWR Site AcceptabilityThe information in this section of the reference ABWR DCD, including all subsections and tables, is incorporated...
Technical Specifications 1.1-1Definitions1.11.0 USE AND APPLICATIONThe information in this section of the reference ABWR DCD, including all subsections, is incorporated by reference with the following departures.STD DEP T1 3.4-1STD DEP 16.3-1001.1 DefinitionsCHANNEL FUNCTION...