Reactor Servicing Equipment 2.5-1STP 3 & 4 Tier 12.5 Reactor Servicing EquipmentThe information in this section of the reference ABWR DCD, including all subsections, tables, and figures, is incorporated by reference with the following departure.STP DEP T1 2.5-12.5.6 Fuel Sto...
Nuclear Steam Supply Systems 2.1-1/2STP 3 & 4 Tier 12.1 Nuclear Steam Supply SystemsThe information in this section of the reference ABWR DCD, including all subsections, tables, and figures, is incorporated by reference with the following departure.STD DEP T1 2.1-22.1.1 Reac...
Potable and Sanitary Water System 4.4-1/2STP 3 & 4 Tier 14.4 Potable and Sanitary Water SystemThe information in this section of the reference ABWR DCD is incorporated by reference with no departures or supplements.Rev. 10
Appendix 12A Calculation of Airborne Radionuclides 12A-1/2STP 3 & 4 Final Safety Analysis Report12A Appendix 12A Calculation of Airborne Radionuclides12A.1 Calculation of Airborne RadionuclidesThe information in this appendix of the reference ABWR DCD, including all subsecti...
HPCF Analysis Outlines 6D-1/2STP 3 & 4 Final Safety Analysis Report 6D HPCF Analysis OutlinesThe information in this appendix of the reference ABWR DCD, including all subsections and figures, is incorporated by reference with one departure which corrects an editorial error.6D...
Onsite Power Systems 8.3-1STP 3 & 4 Final Safety Analysis Report8.3 Onsite Power SystemsThe information in this section of the reference ABWR DCD including all subsections, tables, and figures is incorporated by reference with the following departures and supplements.STD DEP ...
Emergency Core Cooling Systems 6.3-1STP 3 & 4 Final Safety Analysis Report 6.3 Emergency Core Cooling SystemsThe information in this section of the reference ABWR DCD, including all subsections, tables, and figures, is incorporated by reference with the following departures a...
Initial Test Program 3.5-1/2STP 3 & 4 Tier 13.5 Initial Test ProgramThe information in this section of the reference ABWR DCD is incorporated by reference with no departures or supplements.Rev. 11
Differences Between BWROG EPG Revision 4 and ABWR EPG 18B-1STP 3 & 4 Final Safety Analysis Report18B Differences Between BWROG EPG Revision 4 and ABWR EPGThe information in this appendix of the reference ABWR DCD, including all subsections and tables, is incorporated by refer...
Turbine Service Water System 4.6-1/2STP 3 & 4 Tier 14.6 Turbine Service Water SystemThe information in this section of the reference ABWR DCD is incorporated by reference with no departures or supplements.Rev. 11
Emergency Procedures Guidelines—Input Data and Calculation Results 18D-1/2STP 3 & 4 Final Safety Analysis Report18D Emergency Procedures Guidelines—Input Data and Calculation ResultsThe information in this appendix of the reference ABWR DCD, including all subsections and tabl...
Transient and Accident Classification 15.1S-1/2STP 3 & 4 Final Safety Analysis Report15.1S Transient and Accident ClassificationAs specified by Regulatory Guide 1.206 the design differences from the certified design that could impact the STP 3 & 4 transient and safety analysi...
Severe Accident Mitigation Alternatives 7.3-1STP 3 & 4 Environmental Report7.3 Severe Accident Mitigation Alternatives As described in ER Section 7.2, GE performed a generic severe accident analysis for the ABWR as part of the design certification process (Reference 7.3-1). ...
SLs 2.0 STP 3 & 4 2.0-1 Rev. 11 2.0 SAFETY LIMITS (SLs) 2.1 SLs 2.1.1 Reactor Core SLs 2.1.1.1 With the reactor steam dome pressure < 5.41 MPaG or core flow < 10% rated core flow: THERMAL POWER shall be ≤ 25% RTP. 2.1.1.2 With the reactor steam dome pressure ≥ ...
Seismic Capacity Analysis 19H-1STP 3 & 4 Final Safety Analysis Report19H Seismic Capacity AnalysisThe information in this appendix of the reference ABWR DCD, including all subsections, tables and figures, is incorporated by reference with the following departures.STD DEP T1 2...
Other Features of Steam and Power Conversion 10.4-1STP 3 & 4 Final Safety Analysis Report10.4 Other Features of Steam and Power ConversionThe information in this section of the reference ABWR DCD, including all subsections, tables, and figures is incorporated by reference wit...
Power Transmission 2.13-1/2STP 3 & 4 Tier 12.13 Power TransmissionThe information in this section of the reference ABWR DCD is incorporated by reference with no departures or supplements.Rev. 12
Core Cooling Systems 2.4-1STP 3 & 4 Tier 12.4 Core Cooling SystemsThe information in this section of the reference ABWR DCD, including all subsections, tables, and figures, is incorporated by reference with the following departures.STD DEP T1 2.4-1 (Figure 2.4.1a, Table 2.4.1...
Increase in Reactor Pressure 15.2-1STP 3 & 4 Final Safety Analysis Report15.2 Increase in Reactor PressureThe information in this section of the reference ABWR DCD, including all subsections, tables, and figures, is incorporated by reference with the following departures and ...
Nuclear Steam Supply Systems 2.1-1/2STP 3 & 4 Tier 12.1 Nuclear Steam Supply SystemsThe information in this section of the reference ABWR DCD, including all subsections, tables, and figures, is incorporated by reference with the following departure.STD DEP T1 2.1-22.1.1 Reac...
Planning, Development, and Design 18.3-1/2STP 3 & 4 Final Safety Analysis Report18.3 Planning, Development, and DesignThe information in this section of the reference ABWR DCD, including all subsections, is incorporated by reference with no departures or supplements.Rev. 12
Not Used 3F-1/2STP 3 & 4 Final Safety Analysis Report3F Not UsedThe information in this appendix of the reference ABWR DCD is incorporated by reference with no departures or supplements.Rev. 12
Basic Geologic and Seismic Information 2.5S.1-125STP 3 & 4 Final Safety Analysis ReportFigure 2.5S.1-37 Structure Contour Map of Stratum C (Silty Sand)Rev. 12 2.5S.1-126 Basic Geologic and Seismic InformationSTP 3 & 4 Final Safety Analysis ReportFigure 2.5S.1-38 Structure Co...
Direct Containment Heating 19EA-1/2STP 3 & 4 Final Safety Analysis Report19EA Direct Containment HeatingThe information in this appendix of the reference ABWR DCD, including all subsections, tables, and figures, is incorporated by reference with no departures or supplements.R...
Remote Shutdown System 18.5-1/2STP 3 & 4 Final Safety Analysis Report18.5 Remote Shutdown SystemThe information in this section of the reference ABWR DCD is incorporated by reference with no departures or supplements.Rev. 12