Increase in Reactor Coolant Inventory 15.5-1/2STP 3 & 4 Final Safety Analysis Report15.5 Increase in Reactor Coolant InventoryThe information in this section of the reference ABWR DCD, including all subsections, tables, and figures, is incorporated by reference with no depart...
Missile Protection 3.5-1STP 3 & 4 Final Safety Analysis Report3.5 Missile ProtectionThe information in this section of the reference ABWR DCD, including all subsections, tables, and figures, is incorporated by reference with following departure and supplements.STP DEP 3.5-1 (...
Verification Programs 14.0S-1/2STP 3 & 4 Final Safety Analysis Report14.0S Verification ProgramsSection 14.1S identifies specific information to be addressed for the Initial Test Program.Section 14.2 describes the initial test program, including pre-operational testing, initi...
Radioactive Waste Management - Additional Information 11A-1/2STP 3 & 4 Final Safety Analysis Report11A Radioactive Waste Management - Additional InformationAppendix 11A of the reference ABWR DCD referenced proprietary information. The information in this appendix and all subs...
Direct Containment Heating 19EA-1/2STP 3 & 4 Final Safety Analysis Report 19EA Direct Containment HeatingThe information in this appendix of the reference ABWR DCD, including all subsections, tables, and figures, is incorporated by reference with no departures or supplements....
Differences Between BWROG EPG Revision 4 and ABWR EPG 18B-1STP 3 & 4 Final Safety Analysis Report18B Differences Between BWROG EPG Revision 4 and ABWR EPGThe information in this appendix of the reference ABWR DCD, including all subsections and tables, is incorporated by refer...
Probabilistic Flooding Analysis 19R-1STP 3 & 4 Final Safety Analysis Report19R Probabilistic Flooding AnalysisThe information in this section of the reference ABWR DCD, including all subsections, tables, and figures, is incorporated by reference with the following departures ...
Inspections, Tests, Analyses and Acceptance Criteria (ITAAC) 14.3S-1/2STP 3 & 4 Final Safety Analysis Report14.3S Inspections, Tests, Analyses and Acceptance Criteria (ITAAC)The selection criteria and methodology provided in Section 14.3 of the reference ABWR DCD for the cert...
Interlock Systems Important to Safety 7.6S-1/2STP 3 & 4 Final Safety Analysis Report7.6S Interlock Systems Important to SafetySubsections 7.4.1.3 (items 7 and 11), 7.6.1.3, 7.6.2.3, and Table 7.4-1 address interlock functions important to safety.Rev. 08
Operational Radiation Protection Program 12.5S-1STP 3 & 4 Final Safety Analysis Report12.5S Operational Radiation Protection ProgramNuclear Energy Institute Report No. NEI 07-03A, “Generic FSAR Template Guidance for Radiation Protection Program Description” provides the Opera...
Stability of Subsurface Materials and Foundations 2.5S.4-391STP 3 & 4 Final Safety Analysis ReportFigure 2.5S.4-48C Enlarged Southern Plan Rev. DRev. 072.5S.4-392 Stability of Subsurface Materials and FoundationsSTP 3 & 4 Final Safety Analysis ReportFigure 2.5S.4-49A Section...
Implementation Requirements for Hardware/Software Development 7B-1/2STP 3 & 4 Final Safety Analysis Report7B Implementation Requirements for Hardware/Software DevelopmentThe information in this appendix of the reference ABWR DCD, including all subsections, is incorporated by ...
Digital Instrumentation and Control Design Verification for Safety-Related Systems 7DS-1STP 3 & 4 Final Safety Analysis Report7DS Digital Instrumentation and Control Design Verification for Safety-Related SystemsThe purpose of this appendix is to consolidate information regar...
Fuel Coolant Interactions 19EB-1/2STP 3 & 4 Final Safety Analysis Report 19EB Fuel Coolant InteractionsThe information in this appendix of the reference ABWR DCD, including all subsections, tables, and figures, is incorporated by reference with no departures or supplements.Re...
Source Terms 11.1-1/2STP 3 & 4 Final Safety Analysis Report11.0 Radioactive Waste Management11.1 Source TermsThe information in this section of the reference ABWR DCD, including all subsections and tables, is incorporated by reference with no departures or supplementsthe fol...
Probability Analysis of Pressure Regulator Downscale Failure 15D-1/2STP 3 & 4 Final Safety Analysis Report15D Probability Analysis of Pressure Regulator Downscale FailureThe information in this appendix of the reference ABWR DCD, including all subsections, tables, and figures...
Transportation of Radioactive Materials 3.8-1STP 3 & 4 Environmental Report3.8 Transportation of Radioactive MaterialsOperation of STP 3 & 4 would require transportation of unirradiated fuel, irradiated fuel (spent nuclear fuel), and radioactive waste. The subsections that f...
Control Rod Licensing Acceptance Criteria 4C-1/2STP 3 & 4 Final Safety Analysis Report 4C Control Rod Licensing Acceptance CriteriaThe information in this appendix of the reference ABWR DCD, including all subsections, is incorporated by reference with the following standard d...
Failure Modes and Effects Analysis (FMEA) 15B-1STP 3 & 4 Final Safety Analysis Report15B Failure Modes and Effects Analysis (FMEA)The information in this appendix of the reference ABWR DCD, including all subsections, tables, and figures, is incorporated by reference with the ...
Input to the Reliability Assurance Program 19.12-1/2STP 3 & 4 Final Safety Analysis Report19.12 Input to the Reliability Assurance ProgramThe information in this section of the ABWR DCD is incorporated by reference with no departures or supplements.Rev. 06
Reactor Power Conversion System 3.2-1STP 3 & 4 Environmental Report3.2 Reactor Power Conversion SystemThe proposed plant will consist of STP 3 & 4 and their auxiliaries. The power source of each unit is an Advanced Boiling Water Reactor (ABWR) reactor design. The reference AB...
Emergency Procedure Guidelines 18A-1STP 3 & 4 Final Safety Analysis Report18A Emergency Procedure GuidelinesThe information in this appendix of the reference ABWR DCD, including all subsections, tables, and figures, is incorporated by reference with the following departure.ST...
Seismic Capacity Analysis 19H-1STP 3 & 4 Final Safety Analysis Report19H Seismic Capacity AnalysisThe information in this appendix of the reference ABWR DCD, including all subsections, tables and figures, is incorporated by reference with the following departures.STD DEP T1 2...
Emergency Procedures Guidelines—Input Data and Calculation Results 18D-1/2STP 3 & 4 Final Safety Analysis Report18D Emergency Procedures Guidelines—Input Data and Calculation ResultsThe information in this appendix of the reference ABWR DCD, including all subsections and tabl...
Emergency Operation Information and Controls 18F-1STP 3 & 4 Final Safety Analysis Report Tier 218F Emergency Operation Information and ControlsThe information in this appendix of the reference ABWR DCD, including all tables, is incorporated by reference with the following dep...