Basic Geologic and Seismic Information 2.5S.1-90STP 3 & 4 Final Safety Analysis ReportFigure 2.5S.1-2 Site Vicinity Topographic Map (25-mile radius)Rev. 07 2.5S.1-91 Basic Geologic and Seismic InformationSTP 3 & 4 Final Safety Analysis ReportFigure 2.5S.1-3 Site Area Topogra...
Inspections, Tests, Analyses and Acceptance Criteria (ITAAC) 14.3S-1/2STP 3 & 4 Final Safety Analysis Report14.3S Inspections, Tests, Analyses and Acceptance Criteria (ITAAC)The selection criteria and methodology provided in Section 14.3 of the reference ABWR DCD for the cert...
Suppression Pool Bypass 19EE-1/2STP 3 & 4 Final Safety Analysis Report19EE Suppression Pool BypassThe information in this appendix of the reference ABWR DCD, including all subsections, tables, and figures, is incorporated by reference with no departures or supplements.Rev. 07
Inservice Testing Program (OM-2004) 3.9S-1STP 3 & 4 Final Safety Analysis Report3.9S Inservice Testing Program (OM-2004)The following site-specific supplement addresses COL License Information Item 3.29.The Inservice Testing Plan, shown in Table 3.9S-1, has been updated to me...
Fuel Licensing Acceptance Criteria 4B-1/2STP 3 & 4 Final Safety Analysis Report 4B Fuel Licensing Acceptance CriteriaThe information in this appendix of the reference ABWR DCD, including all subsections and tables, is incorporated by reference with no departures or supplement...
Engineered Safety Feature Systems, Instrumentation and Control 7.3-1STP 3 & 4 Final Safety Analysis Report7.3 Engineered Safety Feature Systems, Instrumentation and ControlThe information in this section of the reference ABWR DCD, including all subsections and figures, is inc...
ABWR Human-System Interface Design Implementation Process 18E-1STP 3 & 4 Final Safety Analysis Report18E ABWR Human-System Interface Design Implementation ProcessThe information in this appendix of the reference ABWR DCD, including all subsections, tables and figures, is inco...
Quality Assurance During the Operations Phase 17.2-1/2STP 3 & 4 Final Safety Analysis Report 17.2 Quality Assurance During the Operations PhaseThe information in this section of the reference ABWR DCD is incorporated by reference with the following site-specific supplement.Th...
Physical Security 13.6-1STP 3 & 4 Final Safety Analysis Report 13.6 Physical SecurityThe information in this section of the reference ABWR DCD and the referenced SSAR, including all subsections, is incorporated by reference with the following supplement and departure. Design ...
Source Term Sensitivity Studies 19.5-1/2STP 3 & 4 Final Safety Analysis Report19.5 Source Term Sensitivity StudiesThe information in this section of the reference ABWR DCD, including all subsections, is incorporated by reference with no departures or supplements.Rev. 06
Other Features of Steam and Power Conversion 10.4-1STP 3 & 4 Final Safety Analysis Report10.4 Other Features of Steam and Power ConversionThe information in this section of the reference ABWR DCD, including all subsections, tables, and figures is incorporated by reference wit...
Direct Containment Heating 19EA-1/2STP 3 & 4 Final Safety Analysis Report 19EA Direct Containment HeatingThe information in this appendix of the reference ABWR DCD, including all subsections, tables, and figures, is incorporated by reference with no departures or supplements....
Initial Test Program 3.5-1/2STP 3 & 4 Tier 13.5 Initial Test ProgramThe information in this section of the reference ABWR DCD is incorporated by reference with no departures or supplements.Rev. 06
Habitability Systems 6.4-1/2STP 3 & 4 Final Safety Analysis Report 6.4 Habitability SystemsThe information in this section of the reference ABWR DCD, including all subsections, tables, and figures, is incorporated by reference with the following departure and supplement.STD D...
Accident and Analysis 15.0-1/2STP 3 & 4 Final Safety Analysis Report15.0 Accident and AnalysisThe information in this section of the reference ABWR DCD, including all subsections, tables, and figures, is incorporated by reference with the following supplements.15.0.5 COL Lic...
Fuel Licensing Acceptance Criteria 4B-1/2STP 3 & 4 Final Safety Analysis Report 4B Fuel Licensing Acceptance CriteriaThe information in this appendix of the reference ABWR DCD, including all subsections and tables, is incorporated by reference with no departures or supplement...
Introduction 19.2-1STP 3 & 4 Final Safety Analysis Report19.2 IntroductionThe information in this section of the reference ABWR DCD, including all subsections, and tables, is incorporated by reference with the following departure and supplements.STD DEP Admin (Table 19.2-1)19...
ABWR Shutdown Risk Evaluation 19L-1STP 3 & 4 Final Safety Analysis Report19L ABWR Shutdown Risk EvaluationThe information in this appendix of the reference ABWR DCD, including all subsections, tables, and figures, is incorporated by reference with the following departures.STD...
Power Cycle Systems 2.10-1STP 3 & 4 Tier 12.10 Power Cycle SystemsThe information in this section of the reference ABWR DCD, including all subsections, tables, and figures, is incorporated by reference with the following departure.STD DEP T1 2.10-1 (Figure 2.10.2a and Figure ...
Control Panels 2.7-1STP 3 & 4 Tier 12.7 Control PanelsThe information in this section of the reference ABWR DCD, including all subsections, tables, and figures, is incorporated by reference with the following standard departures.STD DEP T1 2.3-1 (Table 2.7.1a)STD DEP T1 2.14-...
Severe Accident Mitigation Alternatives 7.3-1STP 3 & 4 Environmental Report7.3 Severe Accident Mitigation Alternatives As described in ER Section 7.2, GE performed a generic severe accident analysis for the ABWR as part of the design certification process (Reference 7.3-1). ...
STP 3 & 4 3.0-1LCO Applicability3.03.0 LIMITING CONDITION FOR OPERATION (LCO) APPLICABILITYThe information in this section of the reference ABWR DCD, including all subsections, is incorporated by reference with the following departure.STP DEP 16.3-1LCO 3.0.6 When a supported ...
Probabilistic Evaluations 19D-1/2STP 3 & 4 Final Safety Analysis Report19D Probabilistic Evaluations The information in this appendix of the reference ABWR DCD, including all subsections, is incorporated by reference with no departures or supplements.Rev. 09
Yard Structures and Equipment 2.16-1/2STP 3 & 4 Tier 12.16 Yard Structures and EquipmentThe information in this section of the reference ABWR DCD, including all subsections, tables, and figures, is incorporated by reference with no departures or supplements.Rev. 09
Radioactive Waste Management - Additional Information 11A-1/2STP 3 & 4 Final Safety Analysis Report11A Radioactive Waste Management - Additional InformationAppendix 11A of the reference ABWR DCD referenced proprietary information. The information in this appendix and all subs...