Summary of Analysis Supporting Fire Protection Design Requirements 9B-1/2STP 3 & 4 Final Safety Analysis Report9B Summary of Analysis Supporting Fire Protection Design RequirementsThe information in this appendix of the reference ABWR DCD, including all subsections, tables an...
Human Factors Engineering 3.1-1/2STP 3 & 4 Tier 13.1 Human Factors EngineeringThe information in this section of the reference ABWR DCD, including all tables and figures, is incorporated by reference with no departures or supplements.Rev. 12
Design Basis Accidents 7.1-1STP 3 & 4 Environmental Report7.0 Environmental Impacts of Postulated Accidents Involving Radioactive MaterialsThis chapter assesses the environmental impacts of postulated accidents involving radioactive materials. Section 7.1 evaluates design ba...
Response to TMI Related Matters 1A-1STP 3 & 4 Final Safety Analysis Report1A Response to TMI Related MattersThe information in this appendix of the reference ABWR DCD, including all subsections and tables, is incorporated by reference with the following departures and supplem...
Engineered Safety Feature Systems, Instrumentation and Control 7.3-1STP 3 & 4 Final Safety Analysis Report7.3 Engineered Safety Feature Systems, Instrumentation and ControlThe information in this section of the reference ABWR DCD, including all subsections and figures, is inc...
Reactor Service Water System 4.5-1/2STP 3 & 4 Tier 14.5 Reactor Service Water SystemThe information in this section of the reference ABWR DCD is incorporated by reference with no departures or supplements.Rev. 12
Radiation Monitoring Systems 2.3-1STP 3 & 4 Tier 12.3 Radiation Monitoring SystemsThe information in this section of the ABWR DCD, including all subsections, tables, and figures, is incorporated by reference with the following departures.STD DEP T1 2.3-1 (Figure 2.3.1)STD DEP...
SRP 6.5.1, Table 6.5.1-1 Compliance Assessment 9D-1/2STP 3 & 4 Final Safety Analysis Report9D SRP 6.5.1, Table 6.5.1-1 Compliance AssessmentThe information in this appendix of the reference ABWR DCD is incorporated by reference with no departures or supplements.Rev. 12
Source Terms 11.1-1/2STP 3 & 4 Final Safety Analysis Report11.0 Radioactive Waste Management11.1 Source TermsThe information in this section of the reference ABWR DCD, including all subsections and tables, is incorporated by reference with no departures or supplementsthe fol...
Technical Specifications 1.1-1Definitions1.11.0 USE AND APPLICATIONThe information in this section of the reference ABWR DCD, including all subsections, is incorporated by reference with the following departures.STD DEP T1 3.4-1STD DEP 16.3-1001.1 DefinitionsCHANNEL FUNCTION...
Physical Security 13.6-1STP 3 & 4 Final Safety Analysis Report13.6 Physical SecurityThe information in this section of the reference ABWR DCD and the referenced SSAR, including all subsections, is incorporated by reference with the following supplement and departure. Design c...
Transient and Accident Classification 15.1S-1/2STP 3 & 4 Final Safety Analysis Report15.1S Transient and Accident ClassificationAs specified by Regulatory Guide 1.206 the design differences from the certified design that could impact the STP 3 & 4 transient and safety analysi...
Not Used 19G-1/2STP 3 & 4 Final Safety Analysis Report19G Not UsedThe information in this appendix of the reference ABWR DCD is incorporated by reference with no departures or supplements.Rev. 12
2.5S.1-116 Basic Geologic and Seismic InformationSTP 3 & 4 Final Safety Analysis Report Tier 2Figure 2.5S.1-28 Site Area Geological Map (0.6-mile radius)Rev. 13 Basic Geologic and Seismic Information 2.5S.1-117STP 3 & 4 Final Safety Analysis Report Tier 2Figure 2.5S.1-29 STP...
Equipment Qualification Environmental Design Criteria 3I-1STP 3 & 4 Final Safety Analysis Report Tier 23I Equipment Qualification Environmental Design CriteriaThe information in this section of the reference ABWR DCD, including all subsections, tables, and figures, is incorpo...
Design Response to Appendix B, ABWR LRB Instrumentation and Controls 7A-1STP 3 & 4 Final Safety Analysis Report Tier 27A Design Response to Appendix B, ABWR LRB Instrumentation and ControlsThe information in this section of the reference ABWR DCD, including all subsections, t...
Interlock Systems Important to Safety 7.6S-1/2STP 3 & 4 Final Safety Analysis Report Tier 27.6S Interlock Systems Important to SafetySubsections 7.4.1.3 (items 7 and 11), 7.6.1.3, 7.6.2.3, and Table 7.4-1 address interlock functions important to safety.Rev. 13
Evaluation of Postulated Ruptures in High Energy Pipes 3L-1/2STP 3 & 4 Final Safety Analysis Report Tier 23L Evaluation of Postulated Ruptures in High Energy PipesThe information in this appendix of the reference ABWR DCD, including all subsections and figures, is incorporate...
All Other Instrumentation Systems Required for Safety 7.6-1STP 3 & 4 Final Safety Analysis Report Tier 27.6 All Other Instrumentation Systems Required for SafetyThe information in this section of the reference ABWR DCD, including all subsections, tables, and figures, is incor...
SRP 6.5.1, Table 6.5.1-1 Compliance Assessment 6B-1/2STP 3 & 4 Final Safety Analysis Report Tier 2 6B SRP 6.5.1, Table 6.5.1-1 Compliance AssessmentThe information in this appendix of the reference ABWR DCD is incorporated by reference with the following departure.STD DEP 7.1...
Stability of Subsurface Materials and Foundations 2.5S.4-390STP 3 & 4 Final Safety Analysis Report Tier 2Figure 2.5S.4-48C Enlarged Southern Plan Rev. DRev. 132.5S.4-391 Stability of Subsurface Materials and FoundationsSTP 3 & 4 Final Safety Analysis Report Tier 2Figure 2.5S....
Instrumentation and Control Systems and Platforms 7.1S-1STP 3 & 4 Final Safety Analysis Report Tier 27.1S Instrumentation and Control Systems and PlatformsThis supplemental section provides information for safety-related and nonsafety-related instrumentation and control (I&C)...
SRP 6.5.1, Table 6.5.1-1 Compliance Assessment 9D-1/2STP 3 & 4 Final Safety Analysis Report Tier 29D SRP 6.5.1, Table 6.5.1-1 Compliance AssessmentThe information in this appendix of the reference ABWR DCD is incorporated by reference with no departures or supplements.Rev. 13
Emergency Core Cooling Systems 6.3-1STP 3 & 4 Final Safety Analysis Report Tier 2 6.3 Emergency Core Cooling SystemsThe information in this section of the reference ABWR DCD, including all subsections, tables, and figures, is incorporated by reference with the following depar...
Additional Bypass Leakage Considerations 6E-1/2STP 3 & 4 Final Safety Analysis Report Tier 2 6E Additional Bypass Leakage ConsiderationsThe information in this appendix of the reference ABWR DCD, including all subsections, is incorporated by reference with no departures or su...