Turkey Point 3
2Q/2009 Plant Inspection Findings
Initiating Events
Significance: Jun 30, 2009
Identified By: NRC
Item Type: NCV NonCited Violation
Failure to Implement Procedures for Conducting A Valve Alignment Causes Spill of Reactor Coolant And
Contamination Of A...
May 29, 2001
Garry L. Randolph, Senior Vice
President and Chief Nuclear Officer
Union Electric Company
P.O. Box 620
Fulton, Missouri 65251
SUBJECT: ANNUAL ASSESSMENT LETTER - CALLAWAY PLANT (REPORT 50-483/01-01)
Dear Mr. Randolph:
On May 7, 2001, the NRC staff comp...
November 15, 2004
Mr. George Vanderheyden
Vice President - Calvert Cliffs Nuclear Power Plant
Constellation Generation Group, LLC
1650 Calvert Cliffs Parkway
Lusby, Maryland 20657-4702
SUBJECT: CALVERT CLIFFS NUCLEAR POWER PLANT - NRC EVALUATED
EMERGENCY PREPAREDNESS EXERCI...
April 3, 1998 EA 98-064Florida Power & Light Company ATTN: Mr. T. F. Plunkett President - Nuclear Division P. O. Box 14000 Juno Beach, Florida 33408-0420SUBJECT:NOTICE OF VIOLATION (NRC INSPECTION REPORT NOS. 50-335/98-01, 50-389/98-01)Dear Mr. Plunkett: This refers to th...
Turkey Point 3
3Q/2009 Plant Inspection Findings
Initiating Events
Significance: Jun 30, 2009
Identified By: NRC
Item Type: NCV NonCited Violation
Failure to Implement Procedures for Conducting A Valve Alignment Causes Spill of Reactor Coolant And
Contamination Of A...
McGuire 1
Initiating Events
Significance: Mar 23, 2002
Identified By: Self Disclosing
Item Type: NCV NonCited Violation
Failure to Follow Power Ranger Test Procedure
Licensee Identified Violation of Technical Specification 5.4.1.a, which requires that written procedu...
December 22, 2000
Mr. John K. Wood
Vice President - Nuclear
FirstEnergy Nuclear Operating Company
P. O. Box 97, A200
Perry, OH 44081
SUBJECT: PERRY NUCLEAR POWER PLANT - NRC INSPECTION REPORT
50-440/00-16(DRS)
On November 30, 2000, the NRC completed a routine baseline insp...
March 3, 2003
Mr. Fred Dacimo
Vice President - Indian Point Nuclear Generating Station
Entergy Nuclear Operations, Inc.
295 Broadway, Suite 1
Post Office Box 249
Buchanan, NY 10511-0249
SUBJECT: ANNUAL ASSESSMENT LETTER - INDIAN POINT NUCLEAR GENERATING
UNIT 3 (REPORT 50-2...
March 4, 2002
Garry L. Randolph, Senior Vice
President and Chief Nuclear Officer
Union Electric Company
P.O. Box 620
Fulton, Missouri 65251
SUBJECT: ANNUAL ASSESSMENT - CALLAWAY PLANT (REPORT 50-483/02-01)
Dear Mr. Randolph:
On February 13, 2002, the NRC staff comp...
U.S. Nuclear Regulatory CommissionOperations Center Event Reports For04/22/2010 - 04/23/2010 ** EVENT NUMBERS ** 45782458554585745858458664586745868General Information or OtherEvent Number: 45782 Rep Org: TEXAS DEPARTMENT OF HEALTH Licensee: WEATHERFORD US LP Region: 4 City...
U.S. Nuclear Regulatory CommissionOperations Center Event Reports For12/27/2013 - 12/30/2013 ** EVENT NUMBERS ** 4957849668496694967049678Agreement StateEvent Number: 49578 Rep Org: TEXAS DEPARTMENT OF HEALTH Licensee: MISTRAS GROUP INC Region: 4 City: LA PORTE State: ...
May 15, 2008
The Honorable Nancy Pelosi
Speaker of the United States
House of Representatives
Washington, D.C. 20515
Dear Madam Speaker:
On behalf of the U.S. Nuclear Regulatory Commission (NRC), I am forwarding the
enclosed “Report to Congres...
INFORMATION REPORT
February 10, 2009 SECY-09-0023
For: The Commissioners
From: Vonna L. Ordaz
Assistant for Operations
Office of the Executive Director for Operations
Subject: WEEKLY INFORMATION REPORT - WEEK ENDING
JANUARY 30, 2009
Contents ...
U.S. Nuclear Regulatory CommissionOperations Center Event Reports For02/27/2014 - 02/28/2014 ** EVENT NUMBERS ** 496784984349850498594986049861 !!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!! Power ReactorEvent Number: 49678 Facility: MILLSTONE Regi...
Turkey Point 4
3Q/2009 Plant Inspection Findings
Initiating Events
Significance: Jun 30, 2009
Identified By: NRC
Item Type: NCV NonCited Violation
Failure to Implement Procedures for Conducting A Valve Alignment Causes Spill of Reactor Coolant And
Contamination Of A...
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
01/19/2000 - 01/20/2000
** EVENT NUMBERS **
36596 36601 36604 3...
NRC RESPONSE TO A LETTER TO NRC CHAIRMAN, NILS J. DIAZ
FROM READERS OF EYE ON WACKENHUT
(A Web site hosted by the Service Employees International Union)
REGARDING SECURITY AT NUCLEAR POWER PLANTS
INTRODUCTION
The Nuclear Regulatory Commission (NRC) has received a large...
Diablo Canyon 2
Initiating Events
Significance: Oct 06, 2001
Identified By: NRC
Item Type: NCV NonCited Violation
Failure to perform a prompt operability assessment for an atmospheric dump valve
The inspectors identified a violation for the licensee's failure to prom...
May 29, 2001
Garry L. Randolph, Senior Vice
President and Chief Nuclear Officer
Union Electric Company
P.O. Box 620
Fulton, Missouri 65251
SUBJECT: ANNUAL ASSESSMENT LETTER - CALLAWAY PLANT (REPORT 50-483/01-01)
Dear Mr. Randolph:
On May 7, 2001, the NRC staff comp...
McGuire 2
Initiating Events
Significance: Mar 23, 2002
Identified By: Self Disclosing
Item Type: NCV NonCited Violation
Failure to Follow Steam Pressure Loop Instrument Test Resulting in Reactor Trip
Licensee Identified Violation of Technical Specification 5.4.1., wh...
Diablo Canyon 1
Initiating Events
Significance: Oct 06, 2001
Identified By: NRC
Item Type: NCV NonCited Violation
Failure to perform a prompt operability assessment for an atmospheric dump valve
The inspectors identified a violation for the licensee's failure to prom...
Diablo Canyon 1
Initiating Events
Significance: Oct 06, 2001
Identified By: NRC
Item Type: NCV NonCited Violation
Failure to perform a prompt operability assessment for an atmospheric dump valve
The inspectors identified a violation for the licensee's failure to prom...
March 4, 2002
Garry L. Randolph, Senior Vice
President and Chief Nuclear Officer
Union Electric Company
P.O. Box 620
Fulton, Missouri 65251
SUBJECT: ANNUAL ASSESSMENT - CALLAWAY PLANT (REPORT 50-483/02-01)
Dear Mr. Randolph:
On February 13, 2002, the NRC staff comp...
Seabrook 1
2Q/2003 Plant Inspection Findings
Initiating Events
Mitigating Systems
Significance: Jun 28, 2003
Identified By: NRC
Item Type: NCV NonCited Violation
Failure to Establish a Test Program to Demonstrate Satisfactory Performance of the Enclosure Air Handli...
Turkey Point 3
Initiating Events
Significance: Mar 31, 2001
Identified By: NRC
Item Type: FIN Finding
Corrective actions for previous Unit 4 loss of offsite power incident not thorough.
Green. Some of the licensee's corrective actions in response to a previous Unit 4...