Assessment of RELAP5/MOD2 Against ECN-Reflood Experiments (NUREG/IA-0112, ECN–C—92–008)
On this page:
Download complete document
Publication Information
Date Published: July 1993
Prepared by:
A. Woudstra, J. P. A. Van De Bogaard, P. M. Stoop
Netherlands Energy Research Foundation ECN
Service Unit General Services
P. O. Box 1, NL-1755 ZG Petten
The Netherlands
Prepared as part of:
The Agreement on Research Participation and Technical Exchange
under the International Thermal-Hydraulic Code Assessment
and Application Program (ICAP)
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001
Availability Notice
Abstract
As part of the ICAP (International Code Assessment and Applications Program) agreement between ECN (Netherlands Energy Research Foundation) and USNRC, ECN has performed a number of assessment calculations with the computer program RELAP5.
This report describes the results as obtained by ECN from the assessment of the thermohydraulic computer program RELAP5/MOD2/CY 36.05 versus a series of reflood experiments in a bundle geometry. A total number of seven selected experiments have been analyzed, from the reflood experimental program as previously conducted by ECN under contract of the Commission of the European Communities (CEC). In this document, the results of the analyses are presented and a comparison with the experimental data is provided.
Page Last Reviewed/Updated Wednesday, March 24, 2021