Information Notice No. 86-21, Supplement 1: Recognition of American Society of Mechanical Engineers Accreditation Program for N Stamp Holders
SSINS NO: 6835 IN 86-21, Supplement 1 UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, DC 20555 December 4, 1986 Information Notice No. NO 86-21, Supplement 1: RECOGNITION OF AMERICAN SOCIETY OF MECHANICAL ENGINEERS ACCREDITATION PROGRAM FOR N STAMP HOLDERS Addressees: All nuclear power facilities holding an operating licensee or a construction permit Purpose: This notice is provided to licensees and construction permit holders to clarify the information provided by IN 86-21 on the NRC's recognition of the American Society of Mechanical Engineers (ASME) Accreditation Program for holders of N, NA, NPT, and NV stamps and Certificates of Authorization It is expected that recipients will review the information for applicability to their facilities However, suggestions contained in this information notice do not constitute NRC requirements; therefore, no specific action or written response is required Discussion: IN 86-21 informed licensees that the NRC recognized the ASME Accreditation Program for N, NA, NPT, and NV stamps and the associated Certificates of Authorization IN 86-21 also stated that quality system certificates issued to material manufacturers and material suppliers were excluded from this recognition The statement concerning quality system certificate holders has been misinterpreted by several licensees resulting in quality system certificate holders being removed from approved vendor lists This was not the intent of IN 86-21 Quality system certificate holders were excluded from the recognition announced in IN 86-21 because the quality system certificate program was not covered by the exchange of correspondence between ASME, NRC, and the National Board of Boiler and Pressure Vessel Inspectors If a licensee's NRC approved quality assurance (QA) program allows material manufacturers and material suppliers to be placed on the approved vendor list on the basis of a quality system certificate, then that method of evaluating and selecting vendors is not affected by the issuance of IN 86-21 8612010331 IN 86-21, Supplement 1 December 4, 1986 Page 2 of 2 No specific action or response is required by this information notice If you have any questions regarding this notice, please contact the Regional Administrator of the appropriate NRC regional office or the technical contact listed below Edward L Jordan Director Division of Emergency Preparedness and Engineering Response Office of Inspection and Enforcement Technical Contact: E T Baker, IE 301-492-9663 Attachment: List of Recently Issued IE Information Notices
Page Last Reviewed/Updated Tuesday, March 09, 2021
Page Last Reviewed/Updated Tuesday, March 09, 2021