50.73 Licensee Event Reports that may report Defects and Noncompliance
For persons licensed to operate a nuclear power plant under 10 CFR part 50 or part 52, the evaluation of potential defects and appropriate reporting of defects under §§ 50.72, 50.73, or § 73.71 satisfies each person's evaluation, notification, and reporting obligation to report defects under 10 CFR Part 21. There is no rule that requires a licensee to mention Part 21 when using these alternate reporting means. In order to improve the sharing of Operating Experience with the industry, and increase reactor safety, the NRC will now post certain 50.73 Licensee Event Reports to the table located on this page when the report identifies the existence of a manufacturing defect that has or could cause a loss of safety function. It is important to note that the information contained in a Licensee Event Report (LER) is provided by the licensee, and has not been verified by the NRC to constitute a defect as described in 10 CFR Part 21. The information presented in the following table is provided for information purposes only, and licensees are not required to take any specific action based upon the information provided therein.
This page includes links to files in non-HTML format. See Plugins, Viewers, and Other Tools for more information.
Licensee Event Reports that may report Defects and Noncompliance
LER Number | Licensee | Description | Report Date | Accession No |
---|---|---|---|---|
333202400201 | James A. FitzPatrick Nuclear Power Plant | Reactor Protection System Electric Power Monitoring System Trip Caused Primary Containment Isolation | 11/22/2024 | ML24327A097 |
483202400200 | Callaway Plant Unit 1 | Concurrent Inoperability of Control Room Air Conditioning System Train and Opposite Train Emergency Diesel Generator Results in Condition Prohibited by Technical Specifications Limiting Conditions for Operation 3.7.11, 3.8.1, and 3.0.3 | 10/01/2024 | ML24275A213 |
423202400602 | Millstone Power Station Unit 3 | Pressurizer Power Operated Relief Valve Failed to Open During Surveillance Testing Resulting In a Condition Prohibited byTechnical Specifications | 09/26/2024 | ML24270A029 |
387202400200 | Susquehanna Steam Electric Station Unit 1 | B Diesel Generator Inoperable due to Failed Excitation System Linear Reactor | 09/16/2024 | ML24260A227 |
498202400300 | South Texas Project, Unit 1 | Condition Prohibited by Technical Specifications and Potential Loss of Safety Function Due to Inoperable Low Head Safety Injection Pump | 07/01/2024 | ML24183A174 |
498202400301 | South Texas Project. Unit 1 | Two Essential Chilled Water Trains Inoperable Resulting in a Condition That Could Have Prevented Fulfillment of a Safety Function | 06/19/2024 | ML24171A011 |
321202400100 | Edwin I. Hatch Nuclear Plant, Unit 2 | Primary Containment Penetration Exceeded Maximum Allowable Primary Containment Leakage Rate (La) | 04/15/2024 | ML24100A863 |
355202300301 | R.E. Ginna Nuclear Power Plant, Unit 1 | Manual Reactor Trip due to Degraded Condenser Vacuum from Lowering Main Steam to Air Ejectors and Auxiliary Feedwater Actuation due to low Steam Generator Level |
03/07/2024 | ML24067A253 |
366202300100 | Edwin I. Hatch Nuclear Plant, Unit 2 | Primary Containment Penetration Exceeded Maximum Allowable Primary Containment Leakage Rate (La) | 04/05/2023 | ML23095A088 |
266202100100 | Point Beach Nuclear Plant Unit 1 | Main Feedwater Pump Trip Results in Manual Reactor Trip | 09/28/2021 | ML21271A271 |
416202000401 | Grand Gulf Nuclear Station, Unit 1 | Automatic Reactor Scram Due To Reactor Feed Pump Trip | 08/18/2021 | ML21231A137 |
265202000100 | Quad Cities Nuclear Power Station, Unit 2 |
Loss of Both Divisions of Residual Heat Removal Low Pressure Coolant Injection Due to Swing Bus Failure to Transfer |
05/19/2020 | ML20140A093 |
317201800100 | Calvert Cliffs Nuclear Power Plant, Unit 2 | Both Unit 2 Emergency Diesel Generators Inoperable Due to Depressurization in Common Air Start Headers | 10/07/2018 | ML18345A048 |
315201800100 | Donald C. Cook Nuclear Plant Unit 1 | Unit 1 East Essential Service Water Pump Inoperable Longer Than Allowed by Technical Specifications |
05/31/2018 | ML18155A305 |
440201800100 | Perrv Nuclear Power Plant | Loss of Safety Function and Violation of Technical Specifications due to diode failure | 03/28/2018 | ML18088A060 |
254201700400 | Quad Cities Nuclear Power Station Unit 1 | Unit 1 HPCI Did Not Trip Due to Wear Debris in the Turbine Stop Valve Oil Resetting Solenoid | 01/05/2018 | ML18005A276 |
458201700200 | River Bend Station | Loss of Safety Function of Onsite Electrical Distribution Due to Malfunction of Control Building HVAC System (LER) | 04/18/2017 | ML17116A297 |
Page Last Reviewed/Updated Tuesday, April 15, 2025
Page Last Reviewed/Updated Tuesday, April 15, 2025