Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

2020 Non-Licensee Actions

This page includes links to files in non-HTML format. See Plugins, Viewers, and Other Tools for more information.

NAC International (EA-20-066)                                      

On December 21, 2020, the NRC issued a Notice of Violation to NAC International (Certificate Holder) for a Severity Level III and a Severity Level IV violation.  NAC failed to comply with the requirements of 10 CFR 72.48(c)(2)(viii), “Changes, tests, and experiments,” and 10 CFR 72.146(c), “Design control.”  The violations involved a design change for NAC’s MAGNASTOR dry cask storage system.  The certificate holder failed to utilize a methodology as specified in the MAGNASTOR Final Safety Analysis Report (FSAR); and, failed to obtain an amendment to use a different methodology.  In response, NAC re-performed the spent fuel cask tip-over analysis using the appropriate methodology and obtained satisfactory results.  NAC also implemented corrective actions to enhance its design control and 72.48 screening processes.