The U.S. Nuclear Regulatory Commission is in the process of rescinding or revising guidance and policies posted on this webpage in accordance with Executive Order 14151 Ending Radical and Wasteful Government DEI Programs and Preferencing, and Executive Order 14168 Defending Women From Gender Ideology Extremism and Restoring Biological Truth to the Federal Government. In the interim, any previously issued diversity, equity, inclusion, or gender-related guidance on this webpage should be considered rescinded that is inconsistent with these Executive Orders.

Analysis with TRACE Code of PKL III Tests G1.1 & G1.1a. Study on Heat Transfer Mechanisms in the SG in Presence of Nitrogen, Steam and Water as a Function of the Primary Coolant Inventory in Single Loop Operation (NUREG/IA-0530)

On this page:

Download complete document

Publication Information

Manuscript Completed: April 2022
Date Published: April 2022

Prepared by:
C. Berna, A. Escrivá & J.L. Muñoz-Cobo

Instituto de Ingeniería Energética
Universitat Politècnica de València
Camino de Vera 14, 46022, València, Spain

K. Tien, NRC Project Manager

Division of Systems Analysis
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001

Prepared as part of
The Agreement on Research Participation and Technical Exchange
Under the Thermal-Hydraulic Code Applications and Maintenance Program (CAMP)

Availability Notice

Abstract

The goal of this report is to explain the main results obtained in the simulations performed with the consolidated thermal-hydraulic code TRACE regarding tests PKL III G1.1 and G1.1a. The G1 test series focused on the occurrence of boron dilution processes following the loss of Residual Heat Removal System (RHRS) during ¾-loop operation (primary circuit still closed). Main objective was to provide a data basis for thermal-hydraulics codes for a better understanding of the heat transfer mechanisms in the Steam Generator in presence of Nitrogen, steam and water in the U-tubes and of the coolant transport phenomena observed inside the U-tubes. The main goal of this report is to analyse the capacity of TRACE V5.0p2 code to precisely simulate thermal stratification and natural circulation of both single and biphasic fluxes inside the whole primary circuit.

Page Last Reviewed/Updated Thursday, April 14, 2022