RELAP5/MOD3.3 Assessment against New PMK Experiments (NUREG/IA-0229)

On this page:

Download complete document

Publication Information

Manuscript Completed: August 2006
Date Published: June 2010

Prepared by:
P. Kral

Nuclear Research Institute Rez
Husinec-Rez 130
250 68 Rez, Czech Republic

A. Calvo, NRC Project Manager

Prepared for:
Division of Systems Analysis
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001

Availability Notice

Abstract

The results of RELAP5 post-test analysis of 3 tests performed on the PMK integral test facility are presented and discussed. The Hungarian facility PMK is a scaled-down model of NPP with VVER-440/213 reactor. The code version RELAP5/MOD3.3 Path02 has been assessed against the experimental data from the tests T2.1, T2.2, and T2.3. The tests were focused on medium-break LOCA without HPSI. Generally, RELAP5 predictions are in very good agreement with the measured data.

Page Last Reviewed/Updated Wednesday, March 24, 2021