Abstract
A calculation of LOFT Experiment L3-6, a small break equivalent to a 4-in. diameter rupture in the cold leg of a four-loop commercial pressurized water reactor, has been performed to help validate RELAP5/MOD3.1 for this application.
The version of the code to be used is SCDAP/RELAP5/MOD3.1.8d0.
Three calculations were carried out in order to study the sensitivity to change break nozzle superheated discharge coefficient.
Conducted comparative analysis of the LOFT L3-6 experiment shows on the whole a reasonable agreement between calculated and measured data. Some discrepancies in the system pressure do not distort a picture of the transient.