TRAC-PF1/MOD1 Post-Test Calculations of the OECD LOFT Experiment LP-SB-3 (NUREG/IA-0022)
On this page:
Download complete document
Publication Information
Date Published: April 1990
Prepared by:
E.J. Allen, A.P. Neill
United Kingdom Atomic Energy Authority
Winfrith, Dorchester
Dorset, England
Prepared as part of:
The Agreement on Research Participation and Technical Exchange
under the International Thermal-Hydraulic Code Assessment
and Application Program (ICAP)
Published by:
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555
Availability Notice
Abstract
Analysis of the small, cold leg break, OECD LOFT Experiment LP-SB-3 using the best-estimate computer code TRAC-PFl/MODl is presented.
Descriptions of the LOFT.facility and the LP-SB-3 experiment are given and development of the TRAC-PFl/MOD1 input model is detailed. The caluclations performed in achieving the steady state conditions, from which the experiment was initiated, and the specification of experimental boundary conditions are outlined.
Page Last Reviewed/Updated Thursday, March 25, 2021