The U.S. Nuclear Regulatory Commission is in the process of rescinding or revising guidance and policies posted on this webpage in accordance with Executive Order 14151 Ending Radical and Wasteful Government DEI Programs and Preferencing, and Executive Order 14168 Defending Women From Gender Ideology Extremism and Restoring Biological Truth to the Federal Government. In the interim, any previously issued diversity, equity, inclusion, or gender-related guidance on this webpage should be considered rescinded that is inconsistent with these Executive Orders.

Part 21 Report - 1997-560

LICENSEE: ABB COMBUSTION ENGINEERING SITE: ABB COMBUSTION ENGINEERING EN NUMBER:32762 DOCKET: EVENT DATE: 08-14-97 RX TYPE: EVENT TIME: 00:00 VENDORS: NOTIFY DATE: 08-14-97 EMERGENCY CLASS: N/A REGION: 1 STATE: CT TIME: 14:24 OPS OFFICER: BOB STRANSKY 10 CFR SECTION: CCCC 21.21 UNSPECIFIED PARAGRAPH 10 CFR PART 21 REPORT ENERGY REDISTRIBUTION FACTORS USED IN LARGE-BREAK LOSS OF COOLANT ACCIDENT ANALYSES DO NOT DIRECTLY REFLECT THE EFFECTS OF MODERATOR VOIDING. SPECIFICALLY, THE ENERGY REDISTRIBUTION FACTORS ARE UNDER PREDICTED BY 0.5% TO 1.5%. THIS CORRESPONDS TO A 20�F TO 60�F INCREASE IN PEAK CLAD TEMPERATURE DURING LARGE-BREAK LOSS OF COOLANT ACCIDENTS. THE FOLLOWING UNITS ARE AFFECTED: PALO VERDE UNITS 1, 2, AND 3; SAN ONOFRE UNITS 2 AND 3; WATERFORD UNIT 3; ARKANSAS NUCLEAR ONE UNIT 2; CALVERT CLIFFS UNITS 1 AND 2; AND SAINT LUCIE UNIT 2.

Page Last Reviewed/Updated Wednesday, March 24, 2021