The U.S. Nuclear Regulatory Commission is in the process of rescinding or revising guidance and policies posted on this webpage in accordance with Executive Order 14151 Ending Radical and Wasteful Government DEI Programs and Preferencing, and Executive Order 14168 Defending Women From Gender Ideology Extremism and Restoring Biological Truth to the Federal Government. In the interim, any previously issued diversity, equity, inclusion, or gender-related guidance on this webpage should be considered rescinded that is inconsistent with these Executive Orders.

BWR ECCS Pump Suction Concerns following a LOCA (NUREG-2196)

On this page:

Download complete document

Publication Information

Manuscript Completed: February 2016
Date Published: May 2016

Prepared by:
W.J. Krotiuk, C. Boyd, T. Zaki, W. WangOffice

Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001

Availability Notice

Abstract

This document describes a method to perform a plant-specific assessment to determine whether an emergency core cooling system (ECCS) pump will operate acceptably following a loss-of-coolant accident (LOCA) in a boiling water reactor (BWR) pressure suppression pool. The assessment approach uses the ECCS pump strainer location, the ECCS pump operation criteria, the ECCS pump startup and full operation timing information, and an estimate of the transient pool void fraction information to make the determination.

To support the developed assessment method, this report describes the acceptable ECCS pump operating range necessary to prevent pump damage if noncondensable gas ingestion occurs or to permit recovery from noncondensable gas ingestion. Additionally, this report uses computational fluid dynamics (CFD) analyses to define a noncondensable gas bubble "exclusion zone" and to provide the time-dependent noncondensable void fraction distribution in the suppression pool outside the large gas bubble following a LOCA. The report also lists the test facilities used to test BWR pressure suppression systems and summarizes the available test data that are used to verify the acceptability of the CFD analyses.

Page Last Reviewed/Updated Tuesday, March 09, 2021