Basis Document for Large Early Release Frequency (LERF) Significance Determination Process (SDP): Inspection Findings that May Affect LERF (NUREG-1765)

On this page:

Download complete document

Publication Information

Manuscript Completed: November 2002
Date Published: December 2002

Division of Risk Analysis and Applications
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, D.C. 20555-0001

Availability Notice

Abstract

A significance determination process (SDP) is proposed that assigns risk characterization to inspection findings based on large early release frequency (LERF) considerations. This process is designed to interface directly with the SDP that is based on findings related to those structures, systems, and components (SSCs) that can influence the core damage frequency (CDF). The proposed LERF-based SDP will capture findings for those SSCs that can influence CDF determinations but which can also influence LERF. In addition, the proposed LERF-based SDP approach will address findings related to SSCs that do not influence CDF determinations but which can impact the containment function.

Page Last Reviewed/Updated Wednesday, June 10, 2020