United States Nuclear Regulatory Commission - Protecting People and the Environment

Effect of Material Heat Treatment on Fatigue Crack Initiation in Austenitic Stainless Steels in LWR Environments (NUREG/CR-6878, ANL-03/35)

On this page:

Download complete document

Publication Information

Manuscript Completed: December 2003
Date Published: July 2005

Prepared by:
O.K. Chopra, B. Alexandreanu, and W.J. Shack
Argonne National Laboratory
9700 South Cass Avenue
Argonne, Illinois 60439

P. Krishnaswamy, D. Rudland, and G.M. Wilkowski
Engineering Mechanics Corporation of Columbus
Columbus, Ohio 43221

William H. Cullen, Jr., NRC Project Manager

Prepared for:
Division of Engineering Technology
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001

NRC Job Code Y6388

Availability Notice

Abstract

The ASME Boiler and Pressure Vessel Code provides rules for the design of Class 1 components of nuclear power plants. Figures I-9.1 through I-9.6 of Appendix I to Section III of the Code specify design curves for applicable structural materials. However, the effects of light water reactor (LWR) coolant environments are not explicitly addressed by the Code design curves. The existing fatigue strain-vs.-life (ε-N) data illustrate potentially significant effects of LWR coolant environments on the fatigue resistance of pressure vessel and piping steels. Under certain environmental and loading conditions, fatigue lives of austenitic stainless steels (SSs) can be a factor of 20 lower in water than in air. This report presents experimental data on the effect of heat treatment on fatigue crack initiation in austenitic Type 304 SS in LWR coolant environments. A detailed metallographic examination of fatigue test specimens was performed to characterize the crack morphology and fracture morphology. The key material, loading, and environmental parameters and their effect on the fatigue life of these steels are also described. Statistical models are presented for estimating the fatigue ε-N curves for austenitic SSs as a function of material, loading, and environmental parameters. Two methods for incorporating the effects of LWR coolant environments into the ASME Code fatigue evaluations are presented.

Page Last Reviewed/Updated Thursday, March 12, 2020