United States Nuclear Regulatory Commission - Protecting People and the Environment

Effects of Fuel Failure on Criticality Safety and Radiation Dose for Spent Fuel Casks (NUREG/CR-6835)

On this page:

Download complete document

Publication Information

Manuscript Completed: August 2003
Date Published: September 2003

Prepared by:
KR Elam, J.C. Wagner, C.V. Parks

Oak Ridge National Laboratory
Managed by UT-Battelle, LLC
Oak Ridge, TN 37831-6170

C.J. Withee, NRC Project Manager

NRC Job Code B0009

Prepared for:
Spent Fuel Project Office
Office of Nuclear Material Safety and Safeguards
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001

Availability Notice

Abstract

Irradiation of nuclear fuel to high-burnup values increases the potential for fuel failure during normal and accident conditions involving transport and storage. The objective of this work is to investigate the consequences of potential fuel failure on criticality safety and external dose rates for spent nuclear fuel (SNF) storage and transport casks, with emphasis on high-burnup SNE Analyses were performed to assess the impact of several damaged/failed fuel scenarios on the effective neutron multiplication factor (keff) and external dose rates. The damage or failure was assumed to occur during use in storage or transport, particularly in an accident. Although several of the scenarios go beyond credible conditions, they represent a theoretical limit on the effects of severe accident conditions. Further, the results provide a basis for decision malking with regard to failure potential and a foundation to direct future investigations in this area.

Page Last Reviewed/Updated Friday, March 13, 2020