United States Nuclear Regulatory Commission - Protecting People and the Environment

Production and Testing of the Revised VITAMIN-B6 Fine-Group and the BUGLE-93 Broad-Group Neutron/Photon Cross-Section Libraries Derived From END/B-VI.3 Nuclear Data (NUREG/CR-6214, Revision 1)

On this page:

Download complete document

Publication Information

Manuscript Completed: February 2000
Date Published: April 2000

Prepared by:
J.E. White, D.T. Ingersoll, R.Q. Wright, H.T. Hunter,
C.O. Slater, N.M. Greene, R.E. MacFarlane*, R.W. Roussin

Oak Ridge National Laboratory
Managed by Lockheed Martin Energy Research Corporation
Oak Ridge, TN 37831-6370

*Los Alamos National Laboratory
Los Alamos, NM 87545

C. Fairbanks, NRC Project Manager

Prepared for:
Division of Engineering Technology
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001

NRC Job Code W6164

Availability Notice

Abstract

A revised multigroup cross-section library based on Release 3 of ENDF/B-VI data has been produced and tested for light-water-reactor shielding and reactor pressure vessel dosimetry applications. This new broad-group library, which is designated BUGLE-96, represents an improvement over the BUGLE-93 data library released in February 1994 and replaces the data package for BUGLE-93 in the Radiation Safety Information Computational Center (formerly RSIC). The processing methodology is the same as that used for producing BUGLE-93 and is consistent with ANSI/ANS 6.1.2. The ENDF data were first processed into a fine-group, pseudo-problemindependent format and then collapsed into the final broad-group format. The fine-group library, which is designated VITAMIN-B6, contains 120 nuclides. The BUGLE-96 47-neutron-group/20-gamma-ray-group library contains the same 120 nuclides processed as infinitely dilute and collapsed using a weighting spectrum typical of a concrete shield. Additionally, nuclides processed with resonance self-shielding and weighted using spectra specific to BWR and PWR material compositions and reactor models are available. As an added feature of BUGLE-96, crosssection sets having upscatter data for four thermal neutron groups are included. The upscattering data should improve the application of BUGLE96 to the calculation of more accurate thermal fluences, although more computer time will be required. Several new dosimetry response functions and kerma factors for all 120 nuclides are also included in the library. The incorporation of feedback from users has resulted in a data library that addresses a wider spectrum of user needs.

Page Last Reviewed/Updated Monday, April 06, 2020