Power Reactor Status Report for May 31, 2025

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100
Beaver Valley 2 99 Steam Generator Limitations
Calvert Cliffs 1 93 Increasing Power *
Calvert Cliffs 2 100
FitzPatrick 100

Ginna 100
Hope Creek 1 100
*
Limerick 1 100
Limerick 2 100
*
Millstone 2 100
Millstone 3 100
Nine Mile Point 1 100

Nine Mile Point 2 100
Peach Bottom 2 100
Peach Bottom 3 58
Reduced Power for Maintenance
*
Salem 1 30
Increasing Power
*
Salem 2 100
Seabrook 1 100
Susquehanna 1 100
Susquehanna 2 0 3/24/2025 Refueling Outage

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 100
Browns Ferry 2 0 5/30/2025
Forced Outage; See EN#57737
* 1
Browns Ferry 3 70
Reduced Power for Maintenance
*
Brunswick 1 67
Reduced Power for Rod Pattern Adjustment
*
Brunswick 2 100

Catawba 1 100
Catawba 2 100
Farley 1 100
Farley 2 0 3/16/2025 Refueling Outage
Harris 1 100
Hatch 1 100
Hatch 2 100
McGuire 1 100
McGuire 2 100
North Anna 1 100

North Anna 2 100
Oconee 1 100
Oconee 2 100
Oconee 3 100
Robinson 2 100
Saint Lucie 1 100
Saint Lucie 2 100
Sequoyah 1 100
Sequoyah 2 0 5/30/2025 Forced Outage; Main Generator Maintenance
Summer 100
Surry 1 100

Surry 2 100
Turkey Point 3 100
Turkey Point 4 100

Vogtle 1 60
Holding Power
*
Vogtle 2 100
Vogtle 3 40
Increasing Power
*
Vogtle 4 100 *
Watts Bar 1 100
Watts Bar 2 100

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100
Braidwood 2 100
Byron 1 100
Byron 2 100
Clinton 99 100% Electrical Capability
D.C. Cook 1 100
D.C. Cook 2 100
Davis-Besse 100
Dresden 2 75
Reduced Power for Rod Pattern Adjustment
*
Dresden 3 100
Fermi 2 100
LaSalle 1 100
LaSalle 2 100
Monticello 100
Perry 1 100
Point Beach 1 100
Point Beach 2 100

Prairie Island 1 100
Prairie Island 2 100
Quad Cities 1 100

Quad Cities 2 100

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100
Arkansas Nuclear 2 100
Callaway 0 3/29/2025 Refueling Outage
Columbia Generating Station 0 4/12/2025 Refueling Outage
*
Comanche Peak 1 100
Comanche Peak 2 100
Cooper 100
Diablo Canyon 1 100
Diablo Canyon 2 100
Grand Gulf 1 100
Palo Verde 1 100
Palo Verde 2 100
Palo Verde 3 100
River Bend Station 1 100
South Texas 1 100
South Texas 2 100
Waterford 3 0 4/26/2025 Refueling Outage

*
Wolf Creek 1 100

* - Power Reactor Status Report change within past 24 hours
# - Number of reactor scrams or trips within past 24 hours

Notes:
  • Reactor status data collected between 4 a.m. and 8 a.m. each day.
  • All times are based on eastern time.
  • Additional plant status information is made available on the web page after 28 days.

Page Last Reviewed/Updated Monday, June 30, 2025