Power Reactor Status Report for January 06, 2025

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100
Beaver Valley 2 100
Calvert Cliffs 1 100
Calvert Cliffs 2 100
FitzPatrick 100
Ginna 100
Hope Creek 1 100
Limerick 1 100
Limerick 2 100
*
Millstone 2 100
Millstone 3 100


Nine Mile Point 1 87 Reduced Power Limit due to Fuel Defect
Nine Mile Point 2 100
Peach Bottom 2 100
Peach Bottom 3 100

Salem 1 100
Salem 2 100
Seabrook 1 100
Susquehanna 1 100

Susquehanna 2 100

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 100
Browns Ferry 2 97 Coastdown to Refueling Outage
*
Browns Ferry 3 100
Brunswick 1 100
Brunswick 2 93 Coastdown to Refueling Outage
Catawba 1 100

Catawba 2 100
Farley 1 100 Cold Weather Alert
*
Farley 2 100 Cold Weather Alert
*
Harris 1 100
Hatch 1 100

Hatch 2 89 Coastdown to Refueling Outage
*
McGuire 1 100
McGuire 2 100
North Anna 1 100

North Anna 2 100
Oconee 1 100
Oconee 2 100
Oconee 3 100
Robinson 2 100
Saint Lucie 1 100
Saint Lucie 2 100
Sequoyah 1 100 Cold Weather Alert
Sequoyah 2 0 7/31/2024 Maintenance Outage
Summer 100
Surry 1 100
Surry 2 100
Turkey Point 3 100
Turkey Point 4 100
Vogtle 1 100 Cold Weather Alert
Vogtle 2 100 Cold Weather Alert
Vogtle 3 100 Cold Weather Alert
Vogtle 4 100 Cold Weather Alert
Watts Bar 1 100
Watts Bar 2 100

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100
Braidwood 2 100
Byron 1 100
Byron 2 100
Clinton 100 Cold Weather Alert
*
D.C. Cook 1 100
D.C. Cook 2 100
Davis-Besse 100
Dresden 2 100
Dresden 3 100
Fermi 2 100 Cold Weather Alert
*
LaSalle 1 100
LaSalle 2 100
Monticello 100
Perry 1 100
Point Beach 1 100
Point Beach 2 100
Prairie Island 1 0 9/21/2024 Refueling Outage; RCP Seal Issue.
Prairie Island 2 100
Quad Cities 1 97 Coastdown to Refueling Outage
Quad Cities 2 100

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100 Cold Weather Alert
*
Arkansas Nuclear 2 100 Cold Weather Alert
*
Callaway 100 Cold Weather Alert; Severe Weather Alert
*
Columbia Generating Station 100
Comanche Peak 1 100


Comanche Peak 2 100
Cooper 100
Diablo Canyon 1 100

Diablo Canyon 2 100
Grand Gulf 1 100 Cold Weather Alert
*
Palo Verde 1 100
Palo Verde 2 100
Palo Verde 3 100
River Bend Station 1 100
South Texas 1 100
South Texas 2 100
Waterford 3 94 Transformer Limitation; Cold Weather Alert
*
Wolf Creek 1 100

* - Power Reactor Status Report change within past 24 hours
# - Number of reactor scrams or trips within past 24 hours

Notes:
  • Reactor status data collected between 4 a.m. and 8 a.m. each day.
  • All times are based on eastern time.
  • Additional plant status information is made available on the web page after 28 days.