Power Reactor Status Report for September 08, 2024

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100
High System Voltage Action
*
Beaver Valley 2 100 High System Voltage Action
*
Calvert Cliffs 1 100
High System Voltage Action
*
Calvert Cliffs 2 100
High System Voltage Action
*
FitzPatrick 0 9/4/2024 Refueling Outage
Ginna 100
Hope Creek 1 100
Limerick 1 100


Limerick 2 80 Reduced Power For Maintenance
Millstone 2 100
Millstone 3 0 9/4/2024 Maintenance Outage
*
Nine Mile Point 1 100
Nine Mile Point 2 100
Peach Bottom 2 98 Coastdown To Refueling Outage
*
Peach Bottom 3 100
*
Salem 1 100
Salem 2 100
Seabrook 1 100
Susquehanna 1 100 Minimum 279 MVAR Generation Alert;

High System Voltage Action
*
Susquehanna 2 100
High System Voltage Action
*

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 0 8/31/2024 Refueling Outage
Browns Ferry 2 100
Browns Ferry 3 69 Reduced Power For Rod Pattern Adjustment
*
Brunswick 1 100
Brunswick 2 94
Increasing Power
*
Catawba 1 100
Catawba 2 100
Farley 1 100
Farley 2 100
Harris 1 100
Hatch 1 70 Reduced Power For Turbine Valve Testing
*
Hatch 2 100
McGuire 1 100
McGuire 2 0 9/1/2024 Refueling Outage
North Anna 1 100
North Anna 2 100
Oconee 1 100
Oconee 2 100
Oconee 3 100
Robinson 2 100
Saint Lucie 1 100
Saint Lucie 2 0 8/31/2024 Refueling Outage
Sequoyah 1 100
Sequoyah 2 0 7/31/2024 Refueling Outage
Summer 100

Surry 1 100
Surry 2 100
Turkey Point 3 100

Turkey Point 4 100
Vogtle 1 0 9/8/2024 Refueling Outage
*
Vogtle 2 100
Vogtle 3 100
Vogtle 4 100
Watts Bar 1 100
Watts Bar 2 100

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100
Braidwood 2 100
Byron 1 87 Coastdown To Refueling Outage
Byron 2 100
Clinton 78 Reduced Power For Rod Pattern Adjustment
*
D.C. Cook 1 100
D.C. Cook 2 100
Davis-Besse 100 High System Voltage Action
*
Dresden 2 62 Increasing Power
*
Dresden 3 100
Fermi 2 100
LaSalle 1 100
LaSalle 2 100
Monticello 100
Perry 1 100
Point Beach 1 100
Point Beach 2 100
Prairie Island 1 100
Prairie Island 2 100
Quad Cities 1 100
Quad Cities 2 65 Reduced Power For Maintenance
*

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100
Arkansas Nuclear 2 94 Coastdown To Refueling Outage
*
Callaway 100
Columbia Generating Station 100
Comanche Peak 1 100


Comanche Peak 2 100
Cooper 93 Coastdown To Refueling Outage
Diablo Canyon 1 100
Diablo Canyon 2 100
Grand Gulf 1 100
Palo Verde 1 100
Palo Verde 2 100

Palo Verde 3 100
River Bend Station 1 100

*
South Texas 1 100
South Texas 2 100
Waterford 3 93 Transformer MVAR Limitation
Wolf Creek 1 100

* - Power Reactor Status Report change within past 24 hours
# - Number of reactor scrams or trips within past 24 hours

Notes:
  • Reactor status data collected between 4 a.m. and 8 a.m. each day.
  • All times are based on eastern time.
  • Additional plant status information is made available on the web page after 28 days.

Page Last Reviewed/Updated Monday, October 7, 2024