Power Reactor Status Report for August 20, 2009

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100        
Beaver Valley 2 100        
Calvert Cliffs 1 100   HOT WEATHER ALERT    
Calvert Cliffs 2 100   HOT WEATHER ALERT    
FitzPatrick 100        
Ginna 100        
Hope Creek 1 100   HOT WEATHER ALERT    
Indian Point 2 100   138 KV LINE 33332 L&M FEEDER OOS    
Indian Point 3 100   138 KV LINE 33332 L&M FEEDER OOS    
Limerick 1 100     *  
Limerick 2 100     *  
Millstone 2 100        
Millstone 3 100        
Nine Mile Point 1 100        
Nine Mile Point 2 100        
Oyster Creek 98   INCREASING POWER TO 100% - POWER REDUCED DUE TO HIGH DISCHARGE TEMPERATURE *  
Peach Bottom 2 100     *  
Peach Bottom 3 97   COASTDOWN TO REFUELING OUTAGE *  
Pilgrim 1 100        
Salem 1 100     *  
Salem 2 100     *  
Seabrook 1 100        
Susquehanna 1 94   100% ELECTRICAL CAPABILITY HOT WEATHER ALERT    
Susquehanna 2 94   100% ELECTRICAL CAPABILITY HOT WEATHER ALERT    
Three Mile Island 1 100   HOT WEATHER ALERT    
Vermont Yankee 100        

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 100        
Browns Ferry 2 100        
Browns Ferry 3 100        
Brunswick 1 100        
Brunswick 2 100        
Catawba 1 100        
Catawba 2 100        
Crystal River 3 100        
Farley 1 100        
Farley 2 100        
Harris 1 100        
Hatch 1 100        
Hatch 2 100        
McGuire 1 100        
McGuire 2 98   COASTDOWN TO REFUELING OUTAGE    
North Anna 1 100   HOT WEATHER ALERT    
North Anna 2 100   HOT WEATHER ALERT    
Oconee 1 100        
Oconee 2 100        
Oconee 3 100        
Robinson 2 100        
Saint Lucie 1 100        
Saint Lucie 2 100        
Sequoyah 1 100        
Sequoyah 2 100        
Summer 100        
Surry 1 100   HOT WEATHER ALERT    
Surry 2 100   HOT WEATHER ALERT    
Turkey Point 3 100        
Turkey Point 4 100        
Vogtle 1 100        
Vogtle 2 100        
Watts Bar 1 100        

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100        
Braidwood 2 100        
Byron 1 100        
Byron 2 100        
Clinton 97   100% ELECTRICAL CAPABILITY    
D.C. Cook 1 0 03/02/2009 FORCED OUTAGE - SEE EN #44507    
D.C. Cook 2 100        
Davis-Besse 100        
Dresden 2 100        
Dresden 3 100        
Duane Arnold 100        
Fermi 2 100        
Kewaunee 100        
La Salle 1 100        
La Salle 2 47   INCREASING POWER *  
Monticello 100        
Palisades 100        
Perry 1 100        
Point Beach 1 100        
Point Beach 2 100        
Prairie Island 1 100        
Prairie Island 2 100        
Quad Cities 1 100        
Quad Cities 2 100        

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100        
Arkansas Nuclear 2 100        
Callaway 100        
Columbia Generating Station 0 08/05/2009 FORCED OUTAGE    
Comanche Peak 1 100        
Comanche Peak 2 100        
Cooper 100        
Diablo Canyon 1 100        
Diablo Canyon 2 0 08/13/2009 SHUTDOWN FOR MAINTENANCE ON MAIN BANK TRANSFORMER "A" BUSHING    
Fort Calhoun 100        
Grand Gulf 1 100        
Palo Verde 1 100        
Palo Verde 2 100        
Palo Verde 3 100        
River Bend 1 98   COASTDOWN TO REFUELING OUTAGE *  
San Onofre 2 99        
San Onofre 3 100        
South Texas 1 100        
South Texas 2 100        
Waterford 3 100        
Wolf Creek 1 0 08/19/2009 PLANT TRIP- SEE EN #45278 * 1

* - Power Reactor Status Report change within past 24 hours
# - Number of reactor scrams or trips within past 24 hours

Notes:
  • Reactor status data collected between 4 a.m. and 8 a.m. each day.
  • All times are based on eastern time.

Page Last Reviewed/Updated Thursday, March 29, 2012