Part 21 Report - 1998-631
ACCESSION #: 9809290253
Shared Services Group
P.O. Box [Illegible print]
Seattle, WA [Illegible print]
BOEING
September 23, 1998
G-1151-SJA-98-469
Document Control Desk
United States Nuclear Regulatory Commission
Washington, D.C. 20555
Reference: | a) | Boeing Letter G-1151-RSO-92-365 dated August 31, 1992; R. S. Orr to the NRC Operations Center |
b) | NRC Letter Docket No. 99901227 dated August 12, 1992; L. J. Norrholm to R. S. Orr; Subject: Response to 10 CFR 21 Inquiry |
Dear Sir or Madam:
In accordance with the reference correspondence and 10 CFR 21, Boeing is sending the NRC the attached error notice(s) received from our former software suppliers. Because of unknown current addresses, the following former customers were not notified:
Reactor Controls, Inc.
Echo Energy Consultants, Inc.
Nuclear Applications and Systems Analysis Company (Japan)
Nuclear Power Services
Error notices have been sent to our other former customers.
Very truly yours, Sandra J. Andrews |
Enclosure(s): GTSTRUDL Program Report Form 98.14
Georgia Institute of Technology | GTSTRUDL [Registered Trademark |
September 18, 1998
Attention: Nuclear Administrator
Boeing Information & Support Services
P.O. Box 24346, M/S 7A-33
Seattle, Washington 98124-0346
RE: GT STRUDL
Dear Sir or Madam:
Enclosed please find copies of GTSTRUDL PROGRAM REPORT FORM 98.14, and a GTSTRUDL QA CUSTOMER ACKNOWLEDGMENT FORM. Please sign and return the GTSTRUDL QA CUSTOMER ACKNOWLEDGMENT FORM to acknowledge receipt of the GTSTRUDL Program Report.
Thank you for reviewing the Program Report and for returning the Acknowledgment Form.
Best regards, CASE Center Lawrence Kahn |
Enclosures
Computer Aided Structural Engineering Center | Phone: (404) 894-2260 |
School of Civil & Environmental Engineering | Fax: (404) 894-8014 |
Atlanta, Georgia 30332-0355 USA | casec@ce.gatech.edu |
A Unit of the University System of Georgia
GTSTRUDL Program Report Form GPRF No.: 98.14 DATE: | ||
FROM: | Computer-Aided Structural Engineering Center Georgia Institute of Technology Atlanta, Georgia 30332-0355 | |
SEVERITY LEVEL: | ||
X | URGENT | Problem results in incorrect answers which may not be apparent or job aborts and cannot be recovered within the session or job. |
__ | SERIOUS | Problem results in incorrect answers which are obvious or problem prevents completion of a particular user's task. |
__ | MINOR | Problem can be worked around or problem poses high frustration factor. |
__ | INFORMATIVE | Documentation error, program usage tip, user inconveniences. |
Date Problem Confirmed | ||
Date Notification Sent | ||
Computers | All | |
Operating System | All | |
Versions: | 97.01 and later | |
Target Release for Correction: | 98.02 | |
Mgr. ASD | ||
Signature | Title | |
R & D Division | ||
Michael H. Swanger | ||
Typed or Printed Name | Date of Signature | |
Signature | Title | |
Professional Services Division | ||
Type or Printed Name | Date of Signature | |
Rev. 2.2
GTSTRUDL Program Report Form (Continued) | |||
GPRF No.: 98. | |||
DATE: | |||
DESCRIPTION: | |||
In DELETIONS mode, the SLAVE RELEASES command will abort if the joint list references a joint which is not a slave joint. | |||
Example: | |||
DELETIONS | |||
SLAVE RELEASES | |||
101 TO 105 | |||
ADDITIONS | |||
If joints 101 to 104 are slave joints and joint 105 is not, the SLAVE RELEASES command will abort. | |||
Workaround: | |||
Make certain that the list of joints given with the SLAVE RELEASES command in DELETIONS mode contains only slave joints. | |||
GTSTRUDL User Reference Manual Sections: | |||
Joint Constraints - Rigid Bodies and Joint Ties | Section 2.6.4, Volume 3, GTSTRUDL Reference Manual. |
Rev. 2.2
*** END OF DOCUMENT ***
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021