Skip to main content

Alert

Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Part 21 Report - 1995-165

ACCESSION #: 9505180270

                     THE HARRISON STEEL CASTINGS CO.

               POST OFFICE BOX 60       PHONE 317-762-2481

                          ATTICA, INDIANA 47918

April 11, 1995

US Nuclear Regulatory Commission
Region II
801 Warrenville Road
Lisle, IL 60532-4351

Reference:          NRC License No. 13-92141-01, Amendment 25
Subject:            Trouble Retracting Source

This is a 30-day notification in accordance with 10CFR Part 34.

On April 5, 1995, difficulty was encountered in retracting the cobalt 60
source in the north exposure room into its Amersham 680 projector, serial
no. 381. It was finally retracted to the safe storage position after
repeated cranking in and out. This is the source mentioned in my letter
of March 24, 1995, that has been operated manually pending repair and
return of the 957 automatic exposure controller. There was no apparent
damage nor loose connections in the guide tube; however, it appeared as
though there might be a misalignment between the S-tube and the guide
tube connection nut. Nothing else was noted in the examination. The unit
was taken out of service after the examination. It should be noted that
this 680 has been in constant service since January, 1991, without any
problems. The only modification has been the installation of locking
device required by 10 CFR Part 34.

Amersham was notified on the incident and recommended that we ship them
the 680 for examination and testing. The unit will be shipped after
receipt of shipping labels from Amersham. Amersham stated that they would
perform the 10CFR Part 21 evaluation and make any required notification
to the NRC.

Please contact me if you need further information.

Sincerely yours,


The Harrison Steel Casting Company, Inc.
WD Hollander, RSO

cc:  Dan Lee
     Bob Shepherd
     Harold McBride


*** END OF DOCUMENT ***

Page Last Reviewed/Updated Wednesday, March 24, 2021

Page Last Reviewed/Updated Wednesday, March 24, 2021