Event Notification Report for February 04, 2025

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
02/03/2025 - 02/04/2025

EVENT NUMBERS
57486 57518
Agreement State
Event Number: 57486
Rep Org: SC Dept of Health & Env Control
Licensee: S&ME, Inc.
Region: 1
City: Blythewood   State: SC
County:
License #: 545
Agreement: Y
Docket:
NRC Notified By: Adam Gause
HQ OPS Officer: Tenisha Meadows
Notification Date: 01/06/2025
Notification Time: 14:30 [ET]
Event Date: 01/03/2025
Event Time: 00:00 [EST]
Last Update Date: 02/03/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Lilliendahl, Jon (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
EN Revision Imported Date: 2/4/2025

EN Revision Text: AGREEMENT STATE REPORT - DAMAGED PORTABLE GAUGE

The following information was provided by the South Carolina Department of Environmental Services (the Department) via phone and email:

"The licensee informed the Department on January 3, 2025, a portable moisture density device was hit by a piece of construction equipment which caused the device to be disabled or fail to function as designed. The licensee reported that the source rod was broken, but was found by performing a survey of the area. The licensee reported that the source rod was shielded back in the portable moisture density device, packaged, and transported back to the licensee's facility to await disposal. The licensee reported that no other damage to the portable moisture density device was observed. The portable moisture density device is a Humboldt 5001 gauging device (serial number 3521) housing approximately 10 millicuries of cesium-137 and 40 millicuries of americium-241:beryllium. The licensee did not report any overexposures. The licensee did not call the Department on January 3, 2025. The Department was made aware of the event on January 6, 2025. This event is under investigation by the Department."

South Carolina Event Number: TBD


* * * UPDATE ON 2/3/25 AT 0907 EST FROM ADAM GAUSE TO JOSUE RAMIREZ * * *

The following information was provided by the South Carolina Department of Environmental Services (the Department) via email:

"An on-site investigation was performed on January 6, 2025, at the licensee's facility. The licensee's representatives account of the event was consistent with the initial report. A 30-day written report was received on January 29, 2025. Details of the 30-day written report were consistent with the details obtained from the licensee during the on-site visit and interviews. A leak test record of the portable moisture density device (serial number 3521) dated January 17, 2025, indicated the leak test results of less than 0.005 microcuries. The portable moisture density device (serial number 3521) was transferred to the manufacturer for repair or disposal on January 17, 2025. As a result of this event the licensee will review emergency and operating procedures with all portable moisture density device users. This event is considered closed."

South Carolina Event Number: SC250001

Notified R1DO (Young) and NMSS Events Notification (email).


Fuel Cycle Facility
Event Number: 57518
Facility: American Centrifuge Plant
RX Type: Uranium Enrichment Facility
Comments:
Region: 2
City: Piketon   State: OH
County: Pike
License #: SNM-2011
Docket: 70-7004
NRC Notified By: Mike Leonhart
HQ OPS Officer: Ernest West
Notification Date: 01/28/2025
Notification Time: 12:37 [ET]
Event Date: 01/28/2025
Event Time: 11:00 [EST]
Last Update Date: 01/28/2025
Emergency Class: Non Emergency
10 CFR Section:
PART 70 APP A (c) - Offsite Notification/News Rel
Person (Organization):
Suggs, LaDonna (R2DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
OFFSITE NOTIFICATION

The following information was provided by American Centrifuge Operating, LLC via phone and email:

"An 80 kW Mobile Permit-By-Rule emergency generator with equipment number XQ80 (serial number ME0099) and an emissions number of P540 is expected to exceed the rolling twelve-month threshold of 500 hours by roughly 245 hours. This exceedance is being reported per Ohio Administrative Code, Rule 3745-31-30 [to the Ohio Environmental Protection Agency]."