Skip to main content

Event Notification Report for October 07, 2024

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
10/06/2024 - 10/07/2024

EVENT NUMBERS
573665736557367
Power Reactor
Event Number: 57366
Facility: Turkey Point
Region: 2     State: FL
Unit: [3] [4] []
RX Type: [3] W-3-LP,[4] W-3-LP
NRC Notified By: Ryan Frank
HQ OPS Officer: Karen Cotton-Gross
Notification Date: 10/07/2024
Notification Time: 18:13 [ET]
Event Date: 10/07/2024
Event Time: 17:46 [EDT]
Last Update Date: 10/07/2024
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(xi) - Offsite Notification
Person (Organization):
Suber, Gregory (R2DO)
Grant, Jeffery (IR)
Felts, Russel (NRR)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
3 N Y 100 Power Operation 100 Power Operation
4 N Y 100 Power Operation 100 Power Operation
Event Text
OFFSITE NOTIFICATION

The following information was provided by the licensee via phone and email:

"On October 7, 2024 at 1444 EDT, a contract worker at Turkey Point was transported off-site for treatment at an off-site medical facility.

"On October 7, 2024 at 1746 EST, a courtesy notification was made to OSHA for an individual who was transported to an offsite medical facility for treatment of a personal medical condition. Upon arrival at that facility, medical personnel declared the individual was deceased.

"This event is being reported pursuant to accordance 10 CFR 50.72(b)(2)(xi).

"The NRC Resident Inspector has been notified."



Non-Agreement State
Event Number: 57365
Rep Org: Hemlock Semiconductor
Licensee: Hemlock Semiconductor
Region: 3
City: Saginaw   State: MI
County:
License #: 21-32682-01
Agreement: N
Docket:
NRC Notified By: Jessica Kelly
HQ OPS Officer: Robert A. Thompson
Notification Date: 10/07/2024
Notification Time: 15:57 [ET]
Event Date: 10/07/2024
Event Time: 14:30 [EDT]
Last Update Date: 10/07/2024
Emergency Class: Non Emergency
10 CFR Section:
30.50(b)(2) - Safety Equipment Failure
Person (Organization):
Orlikowski, Robert (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
STUCK-OPEN GAUGE SHUTTER

The following is a summary of information provided by the licensee via phone:

While the licensee was performing semi-annual shutter functional checks, on the initial attempt to close one normally open Vega gauge shutter, resistance was felt. The shutter mechanism was lubricated and a second attempt to close the shutter was made some time later. During this second attempt, two bolts connecting the handle to the shutter sheared off. This disabled the shutter operating mechanism, leaving the shutter stuck open. The licensee verified area radiation levels were unchanged. The licensee has contacted the manufacturer for assistance in repairing the gauge.

The licensee has notified the NRC regional inspector.


Non-Agreement State
Event Number: 57367
Rep Org: Innovative Water Care LLC
Licensee: Innovative Water Care LLC
Region: 1
City: South Charlestown   State: WV
County:
License #: 47-24837-01
Agreement: N
Docket:
NRC Notified By: Katie Musick
HQ OPS Officer: Natalie Starfish
Notification Date: 10/08/2024
Notification Time: 07:27 [ET]
Event Date: 10/07/2024
Event Time: 13:00 [EDT]
Last Update Date: 10/08/2024
Emergency Class: Non Emergency
10 CFR Section:
30.50(b)(2) - Safety Equipment Failure
Person (Organization):
Arner, Frank (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
NON-AGREEMENT STATE REPORT - STUCK OPEN SHUTTER

The following is a summary of information that was provided by the licensee via phone:

The licensee's radiation safety officer reported that during a routine maintenance check at approximately 1300 EDT on 10/07/2024, a gauge shutter would not close. The open position is the normal operating position of the shutter. The source contains 100 mCi of Cs-137.

The gauge is in a normally inaccessible location that has been cordoned off until the manufacturer arrives next week for assessment and repair.

A radiation survey confirmed radiation levels are less than 0.06 mrem/hr. There are no radiation exposure concerns to personnel or the public.