Event Number: 53276
Facility: LASALLE
Region: 3 State: IL
Unit: [1] [] []
RX Type: [1] GE-5,[2] GE-5
NRC Notified By: WAYNE CLAYTON
HQ OPS Officer: OSSY FONT
Region: 3 State: IL
Unit: [1] [] []
RX Type: [1] GE-5,[2] GE-5
NRC Notified By: WAYNE CLAYTON
HQ OPS Officer: OSSY FONT
Notification Date: 03/22/2018
Notification Time: 07:07 [ET]
Event Date: 03/22/2018
Event Time: 03:00 [CDT]
Last Update Date: 03/22/2018
Notification Time: 07:07 [ET]
Event Date: 03/22/2018
Event Time: 03:00 [CDT]
Last Update Date: 03/22/2018
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(i) - PLANT S/D REQD BY TS 50.72(b)(3)(ii)(A) - DEGRADED CONDITION
10 CFR Section:
50.72(b)(2)(i) - PLANT S/D REQD BY TS 50.72(b)(3)(ii)(A) - DEGRADED CONDITION
Person (Organization):
ERIC DUNCAN (R3DO)
ERIC DUNCAN (R3DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 24 | Power Operation | 19 | Power Operation |
TECHNICAL SPECIFICATION REQUIRED SHUTDOWN DUE TO PRESSURE BOUNDARY LEAKAGE
"This notification is being provided in accordance with 10CFR50.72(b)(2)(i), Plant Shutdown required by Technical Specifications, and 10 CFR 50.72(b)(3)(ii)A, Degraded or Unanalyzed Condition.
"At 0300 CDT on 3/22/18, on LaSalle Unit 1, a through-wall (welded joint) leak was identified on a 3/4 inch vent line off of the bonnet of the 1B33-F067B, 1B Reactor Recirculation Pump Discharge Valve. This condition qualifies as pressure boundary leakage, which requires entry into Technical Specification 3.4.5, Reactor Coolant System Operational Leakage, Required Action C, to be in Mode 3, Hot Shutdown, by 1500 on 3/22/18 and Mode 4, Cold Shutdown, by 1500 on 3/23/18. This leakage is significantly less than 10 gallons per minute and therefore, does not meet the threshold for entry into the Emergency Action Plan. At the time of discovery, Unit 1 was in Mode 1 - Run."
Shutdown began at 0500 CDT and the estimated completion to cold shutdown is 2000 CDT. All necessary shutdown equipment is available.
There is no impact to Unit 2.
NRC Resident Inspector was notified.
"This notification is being provided in accordance with 10CFR50.72(b)(2)(i), Plant Shutdown required by Technical Specifications, and 10 CFR 50.72(b)(3)(ii)A, Degraded or Unanalyzed Condition.
"At 0300 CDT on 3/22/18, on LaSalle Unit 1, a through-wall (welded joint) leak was identified on a 3/4 inch vent line off of the bonnet of the 1B33-F067B, 1B Reactor Recirculation Pump Discharge Valve. This condition qualifies as pressure boundary leakage, which requires entry into Technical Specification 3.4.5, Reactor Coolant System Operational Leakage, Required Action C, to be in Mode 3, Hot Shutdown, by 1500 on 3/22/18 and Mode 4, Cold Shutdown, by 1500 on 3/23/18. This leakage is significantly less than 10 gallons per minute and therefore, does not meet the threshold for entry into the Emergency Action Plan. At the time of discovery, Unit 1 was in Mode 1 - Run."
Shutdown began at 0500 CDT and the estimated completion to cold shutdown is 2000 CDT. All necessary shutdown equipment is available.
There is no impact to Unit 2.
NRC Resident Inspector was notified.
Agreement State
Event Number: 53278
Rep Org: OK DEQ RAD MANAGEMENT
Licensee: WESTERN FARMERS ELECTRIC COOP.
Region: 4
City: HUGO State: OK
County:
License #: OK-19428-01
Agreement: Y
Docket:
NRC Notified By: JENNIFER MCALLISTER
HQ OPS Officer: DONALD NORWOOD
Licensee: WESTERN FARMERS ELECTRIC COOP.
Region: 4
City: HUGO State: OK
County:
License #: OK-19428-01
Agreement: Y
Docket:
NRC Notified By: JENNIFER MCALLISTER
HQ OPS Officer: DONALD NORWOOD
Notification Date: 03/22/2018
Notification Time: 10:48 [ET]
Event Date: 03/22/2018
Event Time: 00:00 [CDT]
Last Update Date: 03/22/2018
Notification Time: 10:48 [ET]
Event Date: 03/22/2018
Event Time: 00:00 [CDT]
Last Update Date: 03/22/2018
Emergency Class: NON EMERGENCY
10 CFR Section:
AGREEMENT STATE
10 CFR Section:
AGREEMENT STATE
Person (Organization):
JEREMY GROOM (R4DO)
NMSS EVENTS NOTIFICATION GROUP (EMAIL)
JEREMY GROOM (R4DO)
NMSS EVENTS NOTIFICATION GROUP (EMAIL)
AGREEMENT STATE REPORT - FIXED NUCLEAR GAUGE SHUTTER FAILED CLOSED
The following information was received via E-mail:
The licensee reported on 3/22/2018 that the spring for the shutter cable on a Texas Nuclear Corporation (now TN Technologies) Model 5197 fixed nuclear gauge broke. The shutter is closed and surveys have been taken showing no leakage. The licensee has contacted the manufacturer who will dispatch technicians to repair the device.
Oklahoma Department of Environmental Quality will update this report when more information is known.
* * * UPDATE FROM JENNIFER MCALLISTER TO DONALD NORWOOD AT 1536 EDT ON 3/22/2018 * * *
The following information was received via E-mail:
The event occurred on 3/15/2018. The source is a TN Tech. Model 57157C, 100 mCi, Cs-137 source. The Serial Number of the gauge is B919.
Notified R4DO (Groom) and NMSS Event Notifications.
The following information was received via E-mail:
The licensee reported on 3/22/2018 that the spring for the shutter cable on a Texas Nuclear Corporation (now TN Technologies) Model 5197 fixed nuclear gauge broke. The shutter is closed and surveys have been taken showing no leakage. The licensee has contacted the manufacturer who will dispatch technicians to repair the device.
Oklahoma Department of Environmental Quality will update this report when more information is known.
* * * UPDATE FROM JENNIFER MCALLISTER TO DONALD NORWOOD AT 1536 EDT ON 3/22/2018 * * *
The following information was received via E-mail:
The event occurred on 3/15/2018. The source is a TN Tech. Model 57157C, 100 mCi, Cs-137 source. The Serial Number of the gauge is B919.
Notified R4DO (Groom) and NMSS Event Notifications.
Fuel Cycle Facility
Event Number: 53279
Facility: GLOBAL NUCLEAR FUEL - AMERICAS
Region: 2 State: NC
Unit: [] [] []
RX Type: URANIUM FUEL FABRICATION
Comments: LEU CONVERSION (UF6 TO UO2)
LEU FABRICATION
LWR COMMERICAL FUEL
NRC Notified By: PHILLIP OTIS
HQ OPS Officer: DONALD NORWOOD
Region: 2 State: NC
Unit: [] [] []
RX Type: URANIUM FUEL FABRICATION
Comments: LEU CONVERSION (UF6 TO UO2)
LEU FABRICATION
LWR COMMERICAL FUEL
NRC Notified By: PHILLIP OTIS
HQ OPS Officer: DONALD NORWOOD
Notification Date: 03/22/2018
Notification Time: 16:58 [ET]
Event Date: 03/22/2018
Event Time: 00:00 [EDT]
Last Update Date: 03/22/2018
Notification Time: 16:58 [ET]
Event Date: 03/22/2018
Event Time: 00:00 [EDT]
Last Update Date: 03/22/2018
Emergency Class: NON EMERGENCY
10 CFR Section:
PART 70 APP A (c) - OFFSITE NOTIFICATION/NEWS REL
10 CFR Section:
PART 70 APP A (c) - OFFSITE NOTIFICATION/NEWS REL
Person (Organization):
SHANE SANDAL (R2DO)
NMSS EVENT NOTIFICATIONS (EMAIL)
SHANE SANDAL (R2DO)
NMSS EVENT NOTIFICATIONS (EMAIL)
CONCURRENT REPORT DUE TO LOST TRITIUM EXIT SIGN TUBE
"At approximately 1645 EDT on 3/22/2018, a report was made to the State of North Carolina Department of Radiation Protection. The report is below:
"At approximately 1600 EDT on 3/22/2018 it was determined that a tube from an Everglo Tritium Exit sign was missing. The other three tubes were in the sign. The discovery was made as the sign was being prepared for shipment to disposal. This report is being made in accordance with 10A NCAC 15.1645(a). There is no suspected excessive exposure to employees or members of the public.
"This report to NRC is being made in accordance with 10 CFR 70 Appendix A(c) - Concurrent Reports, '... notification to other government agencies has been or will be made, shall be reported to the NRC Operations Center concurrent to the news release or other notification.'"
See EN 53282 for corresponding report from the State of North Carolina.
THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
"At approximately 1645 EDT on 3/22/2018, a report was made to the State of North Carolina Department of Radiation Protection. The report is below:
"At approximately 1600 EDT on 3/22/2018 it was determined that a tube from an Everglo Tritium Exit sign was missing. The other three tubes were in the sign. The discovery was made as the sign was being prepared for shipment to disposal. This report is being made in accordance with 10A NCAC 15.1645(a). There is no suspected excessive exposure to employees or members of the public.
"This report to NRC is being made in accordance with 10 CFR 70 Appendix A(c) - Concurrent Reports, '... notification to other government agencies has been or will be made, shall be reported to the NRC Operations Center concurrent to the news release or other notification.'"
See EN 53282 for corresponding report from the State of North Carolina.
THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Agreement State
Event Number: 53280
Rep Org: LOUISIANA RADIATION PROTECTION DIV
Licensee: CAN USA INC.
Region: 4
City: HARVEY State: LA
County:
License #: LA-10258-L01, AI#S 164002
Agreement: Y
Docket:
NRC Notified By: JOSEPH NOBLE
HQ OPS Officer: DONALD NORWOOD
Licensee: CAN USA INC.
Region: 4
City: HARVEY State: LA
County:
License #: LA-10258-L01, AI#S 164002
Agreement: Y
Docket:
NRC Notified By: JOSEPH NOBLE
HQ OPS Officer: DONALD NORWOOD
Notification Date: 03/22/2018
Notification Time: 15:12 [ET]
Event Date: 03/22/2018
Event Time: 06:00 [CDT]
Last Update Date: 03/29/2018
Notification Time: 15:12 [ET]
Event Date: 03/22/2018
Event Time: 06:00 [CDT]
Last Update Date: 03/29/2018
Emergency Class: NON EMERGENCY
10 CFR Section:
AGREEMENT STATE
10 CFR Section:
AGREEMENT STATE
Person (Organization):
JEREMY GROOM (R4DO)
NMSS EVENT NOTIFICATIONS (EMAIL)
JEREMY GROOM (R4DO)
NMSS EVENT NOTIFICATIONS (EMAIL)
AGREEMENT STATE REPORT - DISCONNECTED RADIOGRAPHY SOURCE
The following is a synopsis of information received via E-mail:
On March 22, 2018, LA-DEQ (Louisiana Department of Environmental Quality) received an on-line notification that CAN USA Inc. had an incident where a radiography source was irretrievable during operations at a temporary jobsite at the Phillips 66-Alliance Refinery in Belle Chase, LA.
The crew stated they had made an exposure and were performing their post-job survey when the survey meter indicated the source was not in the shielded position. The radiography crew realized the source could not be retracted back into the shielded position and called the assistant RSO (Radiation Safety Officer) for radiation safety assistance.
The assistant RSO arrived at the jobsite at 0615 CDT. The assistant RSO covered the source in the guide tube with lead shot bags to reduce the exposure during the retrieval operation. It was determined that the guide tube had disconnected from the exposure device. The guide tube was reconnected, the source was returned to the shielded position, and an investigation into this incident begun. The assistant RSO completed the retrieval work at approximately 0645 CDT. The assistant RSO's direct read pocket dosimeter had an exposure of approximately 60 mR.
The exposure device and associated equipment (crankout control and source guide tube) were taken to the CAN USA facility for further evaluation. The equipment is a QSA Global Model 880 Delta exposure device, S/N D9222, utilizing a 70.7 Ci Ir-192 source, S/N 63452-G. An internal investigation continues into this irretrievable source incident.
Louisiana Event Report ID No.: LA-180005
* * * UPDATE AT 1730 EDT ON 3/29/18 FROM JOE NOBLE TO JEFF HERRERA * * *
The following update was submitted by the Louisiana Department of Environmental Quality via email:
"Updated information:
"A source retrieval has developed into a situation involving, licensed activities, equipment QC/QA practices and personnel qualifications.
"QSA Global Delta 880, S/N D9222; source [approximately] 70 Ci of Ir-192 s/n 63452-G
Associated Equipment: 3rd party, drive cable and source guide tube. (not Amersham/QSA Global manufactured equipment)
The connector did not appear to be compatible with the exposure device source assembly in the Delta 880 device. (excessive use)
A misconnect/disconnect test was not performed on the source assembly and 3rd party associated equipment (drive cable and guide tube).
Assessment and Evaluation: the exposure device and associated equipment were transferred to QSA Global, Baton Rouge, LA then to QSA Global Burlington, MA.
"CAN USA Inc. was not licensed to perform source retrievals nor did they contact a 'qualified licensed radiation service' company to perform the source retrieval. The Corporate RSO, [deleted] was available by telephone. There was no site/assistant RSO trained or qualified to perform the source retrieval.
"Disconnect happened on a 15 foot elevated catwalk [at] an Aromatics Extractor unit # 1797. The facility, Phillips 66-Alliance, [deleted]. Phillips 66-Alliance Contact: [deleted], EHS Officer
"Personnel:
CAN USA:
Two Radiography Instructors were directly involved in the source retrieval.
Two Carded Radiographers were working with the equipment when it disconnected on the first exposure.
Provided Pocket Dosimeter readings 'provided' were 8 mR, 30 mR, 40 mR and 70 mR.
Landaure whole body badges immediately processes for three individuals, with the Maximum exposure 290 mrem. The acting site RSO, [deleted] whole body badge is 'lost' in the system.
The individuals involved in the source retrieval are having cytogenetic/chromosomal blood sample analysis by REACTS Medical Dosimetry Dept./ORISE.ORAU; results pending.
"Analytical Stress Employees.
Three non-radiation workers were evacuated from the vicinity of the disconnected source and evaluated by blood sample analysis.
"SWAT Specialty Welding and Turnaround:
One non-radiation worker was evacuated from the vicinity of the disconnected source and evaluated by blood sample analysis.
"The Departmental [Louisiana Department of Environmental Quality] investigation is still incomplete depending on assessment, evaluation and analysis results."
The following is a synopsis of information received via E-mail:
On March 22, 2018, LA-DEQ (Louisiana Department of Environmental Quality) received an on-line notification that CAN USA Inc. had an incident where a radiography source was irretrievable during operations at a temporary jobsite at the Phillips 66-Alliance Refinery in Belle Chase, LA.
The crew stated they had made an exposure and were performing their post-job survey when the survey meter indicated the source was not in the shielded position. The radiography crew realized the source could not be retracted back into the shielded position and called the assistant RSO (Radiation Safety Officer) for radiation safety assistance.
The assistant RSO arrived at the jobsite at 0615 CDT. The assistant RSO covered the source in the guide tube with lead shot bags to reduce the exposure during the retrieval operation. It was determined that the guide tube had disconnected from the exposure device. The guide tube was reconnected, the source was returned to the shielded position, and an investigation into this incident begun. The assistant RSO completed the retrieval work at approximately 0645 CDT. The assistant RSO's direct read pocket dosimeter had an exposure of approximately 60 mR.
The exposure device and associated equipment (crankout control and source guide tube) were taken to the CAN USA facility for further evaluation. The equipment is a QSA Global Model 880 Delta exposure device, S/N D9222, utilizing a 70.7 Ci Ir-192 source, S/N 63452-G. An internal investigation continues into this irretrievable source incident.
Louisiana Event Report ID No.: LA-180005
* * * UPDATE AT 1730 EDT ON 3/29/18 FROM JOE NOBLE TO JEFF HERRERA * * *
The following update was submitted by the Louisiana Department of Environmental Quality via email:
"Updated information:
"A source retrieval has developed into a situation involving, licensed activities, equipment QC/QA practices and personnel qualifications.
"QSA Global Delta 880, S/N D9222; source [approximately] 70 Ci of Ir-192 s/n 63452-G
Associated Equipment: 3rd party, drive cable and source guide tube. (not Amersham/QSA Global manufactured equipment)
The connector did not appear to be compatible with the exposure device source assembly in the Delta 880 device. (excessive use)
A misconnect/disconnect test was not performed on the source assembly and 3rd party associated equipment (drive cable and guide tube).
Assessment and Evaluation: the exposure device and associated equipment were transferred to QSA Global, Baton Rouge, LA then to QSA Global Burlington, MA.
"CAN USA Inc. was not licensed to perform source retrievals nor did they contact a 'qualified licensed radiation service' company to perform the source retrieval. The Corporate RSO, [deleted] was available by telephone. There was no site/assistant RSO trained or qualified to perform the source retrieval.
"Disconnect happened on a 15 foot elevated catwalk [at] an Aromatics Extractor unit # 1797. The facility, Phillips 66-Alliance, [deleted]. Phillips 66-Alliance Contact: [deleted], EHS Officer
"Personnel:
CAN USA:
Two Radiography Instructors were directly involved in the source retrieval.
Two Carded Radiographers were working with the equipment when it disconnected on the first exposure.
Provided Pocket Dosimeter readings 'provided' were 8 mR, 30 mR, 40 mR and 70 mR.
Landaure whole body badges immediately processes for three individuals, with the Maximum exposure 290 mrem. The acting site RSO, [deleted] whole body badge is 'lost' in the system.
The individuals involved in the source retrieval are having cytogenetic/chromosomal blood sample analysis by REACTS Medical Dosimetry Dept./ORISE.ORAU; results pending.
"Analytical Stress Employees.
Three non-radiation workers were evacuated from the vicinity of the disconnected source and evaluated by blood sample analysis.
"SWAT Specialty Welding and Turnaround:
One non-radiation worker was evacuated from the vicinity of the disconnected source and evaluated by blood sample analysis.
"The Departmental [Louisiana Department of Environmental Quality] investigation is still incomplete depending on assessment, evaluation and analysis results."
Agreement State
Event Number: 53281
Rep Org: CALIFORNIA RADIATION CONTROL PRGM
Licensee: NBC UNIVERSAL
Region: 4
City: UNIVERSAL CITY State: CA
County:
License #: GL
Agreement: Y
Docket:
NRC Notified By: THOMAS GEZA MIKO
HQ OPS Officer: ANDREW WAUGH
Licensee: NBC UNIVERSAL
Region: 4
City: UNIVERSAL CITY State: CA
County:
License #: GL
Agreement: Y
Docket:
NRC Notified By: THOMAS GEZA MIKO
HQ OPS Officer: ANDREW WAUGH
Notification Date: 03/22/2018
Notification Time: 21:47 [ET]
Event Date: 03/22/2018
Event Time: 00:00 [PDT]
Last Update Date: 03/22/2018
Notification Time: 21:47 [ET]
Event Date: 03/22/2018
Event Time: 00:00 [PDT]
Last Update Date: 03/22/2018
Emergency Class: NON EMERGENCY
10 CFR Section:
AGREEMENT STATE
10 CFR Section:
AGREEMENT STATE
Person (Organization):
JEREMY GROOM (R4DO)
NMSS_EVENT_NOTIFICATIONS (EMAIL)
JEREMY GROOM (R4DO)
NMSS_EVENT_NOTIFICATIONS (EMAIL)
AGREEMENT STATE REPORT - BROKEN TRITIUM EXIT SIGN
The following is a synopsis of information received via E-mail from the State of California:
On March 22, 2018 the Director of Environmental Affairs at NBC Universal (i.e. Universal Studios) in Universal City, California called Los Angeles County Radiation Management to report the discovery of a broken Tritium exit sign. The Tritium sign was subsequently isolated for secure and safe keeping. A Los Angeles County Radiation Management employee will visit Universal Studios on March 23, 2018 to check for Tritium leakage or contamination.
The broken sign is a Forever Lite Inc. Tritium sign, S/N 286342, with an expiration date of March 2027, containing 11.21 Curies.
California 5010 Number: 032218
The following is a synopsis of information received via E-mail from the State of California:
On March 22, 2018 the Director of Environmental Affairs at NBC Universal (i.e. Universal Studios) in Universal City, California called Los Angeles County Radiation Management to report the discovery of a broken Tritium exit sign. The Tritium sign was subsequently isolated for secure and safe keeping. A Los Angeles County Radiation Management employee will visit Universal Studios on March 23, 2018 to check for Tritium leakage or contamination.
The broken sign is a Forever Lite Inc. Tritium sign, S/N 286342, with an expiration date of March 2027, containing 11.21 Curies.
California 5010 Number: 032218
Agreement State
Event Number: 53282
Rep Org: NC DIV OF RADIATION PROTECTION
Licensee: GE HITACHI
Region: 1
City: WILMINGTON State: NC
County:
License #: 0317-3
Agreement: Y
Docket:
NRC Notified By: TRAVIS CARTOSKI
HQ OPS Officer: DONALD NORWOOD
Licensee: GE HITACHI
Region: 1
City: WILMINGTON State: NC
County:
License #: 0317-3
Agreement: Y
Docket:
NRC Notified By: TRAVIS CARTOSKI
HQ OPS Officer: DONALD NORWOOD
Notification Date: 03/23/2018
Notification Time: 12:42 [ET]
Event Date: 03/22/2018
Event Time: 00:00 [EDT]
Last Update Date: 03/23/2018
Notification Time: 12:42 [ET]
Event Date: 03/22/2018
Event Time: 00:00 [EDT]
Last Update Date: 03/23/2018
Emergency Class: NON EMERGENCY
10 CFR Section:
AGREEMENT STATE
10 CFR Section:
AGREEMENT STATE
Person (Organization):
RAY MCKINLEY (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
RAY MCKINLEY (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - MISSING TUBE FROM TRITIUM EXIT SIGN
The following information was received via E-mail:
"Licensee reports that on 3/22/2018 it was determined that a tube from an Everglo Tritium Exit sign was missing. The other three tubes were in the sign. The discovery was made as the sign was being prepared for shipment to disposal. At this time, there is no suspected excessive exposure to employees or members of the public.
"Licensee will follow up with additional information [as required] per 10 CFR 20.2201(b). When this report is received by the NC Radioactive Materials Branch, this event will be updated to complete the record."
NC Event Tracking Number: 180013
See EN 53279 for corresponding report from licensee.
THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following information was received via E-mail:
"Licensee reports that on 3/22/2018 it was determined that a tube from an Everglo Tritium Exit sign was missing. The other three tubes were in the sign. The discovery was made as the sign was being prepared for shipment to disposal. At this time, there is no suspected excessive exposure to employees or members of the public.
"Licensee will follow up with additional information [as required] per 10 CFR 20.2201(b). When this report is received by the NC Radioactive Materials Branch, this event will be updated to complete the record."
NC Event Tracking Number: 180013
See EN 53279 for corresponding report from licensee.
THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Agreement State
Event Number: 53283
Rep Org: CALIFORNIA RADIATION CONTROL PRGM
Licensee: QUASLPEC, LLC (currently merged with TEAM)
Region: 4
City: BENICIA State: CA
County:
License #: 5299-07
Agreement: Y
Docket:
NRC Notified By: ARUNIKA HEWADIKARAM
HQ OPS Officer: DONALD NORWOOD
Licensee: QUASLPEC, LLC (currently merged with TEAM)
Region: 4
City: BENICIA State: CA
County:
License #: 5299-07
Agreement: Y
Docket:
NRC Notified By: ARUNIKA HEWADIKARAM
HQ OPS Officer: DONALD NORWOOD
Notification Date: 03/23/2018
Notification Time: 16:49 [ET]
Event Date: 03/22/2018
Event Time: 00:00 [PDT]
Last Update Date: 03/23/2018
Notification Time: 16:49 [ET]
Event Date: 03/22/2018
Event Time: 00:00 [PDT]
Last Update Date: 03/23/2018
Emergency Class: NON EMERGENCY
10 CFR Section:
AGREEMENT STATE
10 CFR Section:
AGREEMENT STATE
Person (Organization):
JEREMY GROOM (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
JEREMY GROOM (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - RADIOGRAPHY PERSONNEL OVEREXPOSURE
The following information was received via E-mail:
"On 03/23/18, the Radiation Safety Officer (RSO) (appointed RSO since the merge with TEAM) contacted RHB (California Department of Public Health, Radiologic Health Branch) to report an occupational overexposure to one of their radiographer trainers. On 03/22/18, the licensee was made aware of an overexposure to a trainer when the trainer's instadose dosimeter was processed. The badge reading indicated a whole body exposure of 5769 mR (licensee processes instadose dosimetry every two weeks for all the users). Further investigation revealed that the radiographer assistant that worked with this trainer also received a whole body exposure of 4583 mR. Preliminary investigation indicates the individuals may have received the recorded exposure during radiographic operations conducted at Chevron Refinery, Richmond, CA, where the source apparently may not have been fully retracted into the shielded position following an exposure. It is believed that a confirmatory survey was not performed following the exposure.
"The exposure device involved is an INC-IR100 camera, device S/N 6756, with an activity of 88.9 Ci of Ir-192.
"Both individuals have been removed from any radiographic operations. The exposure device was inspected and did not show any signs of defects or damages. The licensee's investigation is ongoing and RHB will be following up on this incident.
"Note: RHB is in the process of merging the two licenses, Qualspec, LLC and Team Industrial Services RML # 6720."
California 5010 Number: 032318
The following information was received via E-mail:
"On 03/23/18, the Radiation Safety Officer (RSO) (appointed RSO since the merge with TEAM) contacted RHB (California Department of Public Health, Radiologic Health Branch) to report an occupational overexposure to one of their radiographer trainers. On 03/22/18, the licensee was made aware of an overexposure to a trainer when the trainer's instadose dosimeter was processed. The badge reading indicated a whole body exposure of 5769 mR (licensee processes instadose dosimetry every two weeks for all the users). Further investigation revealed that the radiographer assistant that worked with this trainer also received a whole body exposure of 4583 mR. Preliminary investigation indicates the individuals may have received the recorded exposure during radiographic operations conducted at Chevron Refinery, Richmond, CA, where the source apparently may not have been fully retracted into the shielded position following an exposure. It is believed that a confirmatory survey was not performed following the exposure.
"The exposure device involved is an INC-IR100 camera, device S/N 6756, with an activity of 88.9 Ci of Ir-192.
"Both individuals have been removed from any radiographic operations. The exposure device was inspected and did not show any signs of defects or damages. The licensee's investigation is ongoing and RHB will be following up on this incident.
"Note: RHB is in the process of merging the two licenses, Qualspec, LLC and Team Industrial Services RML # 6720."
California 5010 Number: 032318