Skip to main content

Event Notification Report for July 8, 2009

U.S. Nuclear Regulatory Commission
Operations Center

Event Reports For
07/07/2009 - 07/08/2009

** EVENT NUMBERS **


45182 45188

To top of page
General Information or Other Event Number: 45182
Rep Org: PA BUREAU OF RADIATION PROTECTION
Licensee: CHESTER COUNTY HOSPITAL
Region: 1
City: WEST CHESTER State: PA
County: CHESTER
License #: PA-0071
Agreement: Y
Docket:
NRC Notified By: DAVE ALLARD
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 07/02/2009
Notification Time: 23:28 [ET]
Event Date: 05/13/2009
Event Time: [EDT]
Last Update Date: 07/02/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
AGREEMENT STATE
Person (Organization):
JAMES TRAPP (R1DO)
DUNCAN WHITE (FSME)

Event Text

AGREEMENT STATE REPORT - FETAL EXPOSURE FROM RADIOIODINE THERAPY

The following report was received via facsimile:

"Patient was administered 54.1 mCi of I-131 on 3/30/2009. Patient had a false negative pregnancy test on 3/30/2009. Patient found out on May 13, 2009 that she was 9.5 weeks pregnant. Therefore, the therapy dose was given 5 days post-conception. Dose Eq to embryo/fetus = 11.9cGy. Dose Eq to fetal thyroid = 0.97cGy

"PA DEP Bureau of Radiation Protection was notified in writing, dated May 22, 2009, [from] the Radiation Safety Officer.

"The State has an inspection scheduled sometime in the future and will continue to keep NRC informed of the status of our investigation."

PA event: PA090024

To top of page
Fuel Cycle Facility Event Number: 45188
Facility: PORTSMOUTH GASEOUS DIFFUSION PLANT
RX Type: URANIUM ENRICHMENT FACILITY
Comments: 2 DEMOCRACY CENTER
                   6903 ROCKLEDGE DRIVE
                   BETHESDA, MD 20817 (301)564-3200
Region: 2
City: PIKETON State: OH
County: PIKE
License #: GDP-2
Agreement: Y
Docket: 0707002
NRC Notified By: RON CRABTREE
HQ OPS Officer: DONALD NORWOOD
Notification Date: 07/07/2009
Notification Time: 01:57 [ET]
Event Date: 07/07/2009
Event Time: 00:54 [EDT]
Last Update Date: 07/07/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
OTHER UNSPEC REQMNT
Person (Organization):
RANDY MUSSER (R2DO)
EARL EASTON (NMSS)

Event Text

4-HOUR REPORT DUE TO NOTIFICATION OF OHIO EPA BECAUSE OF BOILER OPACITY LIMIT BEING EXCEEDED

"At 2130 hours, 07/06/09, the PORTS Plant Shift Superintendent's (PSS) Office was notified of an operational upset at the X-600 Steam Plant Facility due to a loss of power on the #3 (operating) Boiler. The operational upset resulted in three separate six minute periods, where the permissible opacity limit was exceeded, while power was being restored to the boiler. The PORTS PSS Office notified the Ohio Environmental Protection Agency (OEPA) of this incident, at 0054 hours, 07/07/09. This notification to another government agency is reportable to the NRC as a 4-hour Event, per the United States Enrichment Corporation (USEC) Nuclear Regulatory Event Reporting Procedure UE2-RA-RE1030, Appendix D, Section P (Miscellaneous) which states: 'USEC shall notify NRC of any event or situation, related to the health and safety of the public or on-site personnel, or protection of the environment, for which a news release is planned or notification to other government agencies has been or will be made. Such an event may include an on-site fatality or inadvertent release of radioactively contaminated materials'."

The licensee notified the Paducah NRC Resident Inspector.

Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021