Event Notification Report for March 21, 2003
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
03/20/2003 - 03/21/2003
** EVENT NUMBERS **
39681 39682 39683
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 39681 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: BRUNSWICK REGION: 2 |NOTIFICATION DATE: 03/19/2003|
| UNIT: [1] [] [] STATE: NC |NOTIFICATION TIME: 23:15[EST]|
| RXTYPE: [1] GE-4,[2] GE-4 |EVENT DATE: 03/19/2003|
+------------------------------------------------+EVENT TIME: 21:30[EST]|
| NRC NOTIFIED BY: David Jester |LAST UPDATE DATE: 03/20/2003|
| HQ OPS OFFICER: ERIC THOMAS +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |CAUDLE JULIAN R2 |
|10 CFR SECTION: | |
|APRE 50.72(b)(2)(xi) OFFSITE NOTIFICATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 94 Power Operation |94 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| SINK HOLE IN SITE STABILIZATION POND |
| |
| "The site stabilization pond has developed a sink hole which has created a |
| partial bypass of the normal treatment system from an unauthorized release |
| point. The stabilization pond receives water pumped from a Storm Drain Basin |
| which collects storm drainage from various areas around the site. This |
| release from an unauthorized discharge point requires notification to the |
| State of North Carolina in accordance with our NPDES permit. This report |
| initiated per [50.72(b)(2)(xi)] due to State of North Carolina |
| notification." |
| |
| The licensee has notified the NRC Resident Inspector. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 39682 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SUSQUEHANNA REGION: 1 |NOTIFICATION DATE: 03/20/2003|
| UNIT: [1] [2] [] STATE: PA |NOTIFICATION TIME: 04:39[EST]|
| RXTYPE: [1] GE-4,[2] GE-4 |EVENT DATE: 03/20/2003|
+------------------------------------------------+EVENT TIME: 00:15[EST]|
| NRC NOTIFIED BY: Robert Boesch |LAST UPDATE DATE: 03/20/2003|
| HQ OPS OFFICER: ERIC THOMAS +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |PETE ESELGROTH R1 |
|10 CFR SECTION: | |
|AINC 50.72(b)(3)(v)(C) POT UNCNTRL RAD REL | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
|2 N N 0 Refueling |0 Refueling |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| INOPERABLE SECONDARY CONTAINMENT |
| |
| "On 3/20/03 at 0015 hours during performance of Secondary Containment |
| drawdown testing, it was determined that the Technical Specification maximum |
| allowed combined flowrate of 2885 SCFM for Zone 1 and Zone 3 was exceeded. |
| The average flow for the two zones was approximately 3000 SCFM. The |
| condition required the Station to declare both zones inoperable, and placed |
| Unit 1 in a 4 hour LCO to restore Secondary Containment. Unit 2 is already |
| in Mode 5, however the condition would have prevented all additional fuel |
| moves. The Standby Gas Treatment System was capable of maintaining the DP |
| requirement of 0.25 " vac. water gauge during the test. By 0330 |
| investigation had reduced flow from the two zones to approximately 2600 |
| SCFM, and the LCO was exited. The inoperability of Secondary Containment is |
| a loss of an entire Safety Function that is needed to control the release of |
| radioactive material, and is reportable under 10CFR50.72(b)(3)(v)(c)." |
| |
| The licensee notified the NRC Resident Inspector. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 39683 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PALO VERDE REGION: 4 |NOTIFICATION DATE: 03/20/2003|
| UNIT: [1] [2] [3] STATE: AZ |NOTIFICATION TIME: 13:13[EST]|
| RXTYPE: [1] CE,[2] CE,[3] CE |EVENT DATE: 03/20/2003|
+------------------------------------------------+EVENT TIME: 08:30[MST]|
| NRC NOTIFIED BY: DAN MARKS |LAST UPDATE DATE: 03/20/2003|
| HQ OPS OFFICER: ARLON COSTA +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |CLAUDE JOHNSON R4 |
|10 CFR SECTION: | |
|APRE 50.72(b)(2)(xi) OFFSITE NOTIFICATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 97 Power Operation |97 Power Operation |
|2 N Y 98 Power Operation |98 Power Operation |
|3 N Y 99 Power Operation |99 Power Operation |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| MEDIA COVERAGE OF TERRORIST TARGET |
| |
| "The following event description is based on information currently |
| available. If through subsequent reviews of this event, additional |
| information is identified that is pertinent to this event or alters the |
| information being provided at this time, a follow-up notification will be |
| made via the ENS or under the reporting requirements of 10CFR50.73. |
| |
| "This ENS notification is to inform the agency of an issue within the NRC's |
| purview that may affect or raise a concern about the public health and |
| safety. |
| |
| "It has been reported in two news articles that the Palo Verde Nuclear |
| Generating Station has been identified as a terrorist target. These two |
| articles have been copied from the internet |
| [ww.cnn.com/2003/US/Southwest/03/20/nuclear.plant.threat/index.html and |
| www.washtimes.com/national/20030320-43174000.htm] and attached to this |
| notification. We have also been informed of television coverage on the same |
| subject on CNN and local networks. |
| |
| "The Palo Verde Nuclear Generating Station is prepared to respond to media |
| questions, but has no plans to issue a press release. |
| |
| "The NRC Resident Inspector has been notified of this ENS call." |
+------------------------------------------------------------------------------+