The U.S. Nuclear Regulatory Commission is in the process of rescinding or revising guidance and policies posted on this webpage in accordance with Executive Order 14151 Ending Radical and Wasteful Government DEI Programs and Preferencing, and Executive Order 14168 Defending Women From Gender Ideology Extremism and Restoring Biological Truth to the Federal Government. In the interim, any previously issued diversity, equity, inclusion, or gender-related guidance on this webpage should be considered rescinded that is inconsistent with these Executive Orders.

SONGS Unit 3 Failed In-situ Pressure Tests

In-situ Testing Summary Unit 3 SG 3E088

Tube Location Max Pressure Reached Percent Wear (%) Length of Wear (in)
*   Row 106 Column 78 2874 100 29
     Row 106 Column 78 3268 99 23
     Row 104 Column 78 3180 99 27
     Row 100 Column 80 4732 81 28
     Row 107 Column 77 5160 80 34
     Row 101 Column 81 4889 78 26
     Row 98 Column 80 4886 72 29
     Row 99 Column 81 5026 72 27

Page Last Reviewed/Updated Wednesday, March 11, 2020