Skip to main content

Alert

The NRC is shutdown due to the lapse in appropriations. Exempted activities to maintain critical health and safety activities and progress on critical activities, including activities outlined in Executive Order 14300, as described in the OMB Approved NRC Lapse Plan will continue.

Evaluation of Simulator Adequacy for the Radiation Qualification of Safety-Related Equipment (NUREG/CR-1184,SAND79-1787)

On this page:

Download complete document

Publication Information

Manuscript Completed: August 1979
Date Published: May 1980

Prepared by:
Lloyd L. Bonzon and William H. Buckalew
Sandia National Laboratories
Albuquerque, NM 87185
Operated by Sandia Corporation for the U.S. Department of Energy

Prepared for:
Research Support Branch
Office of Water Reactor Safety Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001

Under Interagency Agreement DOE 40-550-75

NRC FIN A-1051-0

Availability Notice

Abstract

This analysis of the response of a reactor power cable to a loss-of-coolant accident (LOCA) discusses several different possible failure mechanisms. In the first few fractions of a minute the electrical leakage currents flow and trapped electrons may discharge, inducing noise pulses into the cable. Quantitative analysis shows these effects are not serious for a power cable.

If the cable has poor heat contact with the external environment, within a few minutes radiation energy (dose) will raise the temperature from an already elevated temperature to approach the maximum service temperature for the insulators.

After a few days the accumulated dose is enough to deteriorate the cable insulation. This chemical and mechanical deterioration thus represents the ultimate failure mode of the cable.

It is noted that gamma ray simulators may understress the electrical effects and overstress the temperature effects. It is also noted that several parameters used in this study were extrapolated from the values for roughly similar materials in roughly similar environments. A final, definitive study might have to include a program to measure these parameters in the materials of interest.